Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
IAC Center Rutgers, State Univ. of NJ
Assessment Year 1992
Principal Product COMMERCIAL FOLDING BOXES
NAICS n/a
SIC 2657 - Folding Paperboard Boxes
Sales $10,000,000-$50,000,000
# of Employees 137
Plant Area (Sq.Ft.) 0
Annual Production 250,000,000 Pieces
Production Hrs. Annual 7,200
Location (State) NJ
Source Yearly Cost Usage Unit Unit Cost
Electricity Usage $182,715 1,981,536 kWh $0.09
Natural Gas $46,022 8,237 MMBtu $5.59
TOTAL ENERGY COSTS $228,737
RECOMMENDED SAVINGS* $40,592 *Non-energy impacts
included in savings.
See recommendations below
IMPLEMENTED SAVINGS* $40,592
#|Description Savings
Cost
Status Electricity Usage Natural Gas Administrative Changes Electricity Usage Natural Gas Administrative Changes
$ kWh $ MMBtu $ $
01: 2.6121 REDUCE HOT WATER TEMPERATURE TO THE MINIMUM REQUIRED Savings:
$10,985
Cost:
$201
$10,985 119,285 - - - - $10,985
119,285
kWh
-
-
MMBtu
-
-
$
02: 2.4221 INSTALL COMPRESSOR AIR INTAKES IN COOLEST LOCATIONS Savings:
$1,401
Cost:
$68
$1,401 15,240 - - - - $1,401
15,240
kWh
-
-
MMBtu
-
-
$
03: 2.7142 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS Savings:
$3,050
Cost:
$2,523
$3,416 37,222 - - $(-366) - $3,416
37,222
kWh
-
-
MMBtu
$(-366)
-
$
04: 2.3191 USE DEMAND CONTROLLER OR LOAD SHEDDER Savings:
$10,165
Cost:
$2,500
$10,165 - - - - - $10,165
-
kWh
-
-
MMBtu
-
-
$
05: 2.1233 ANALYZE FLUE GAS FOR PROPER AIR/FUEL RATIO Savings:
$921
Cost:
$500
- - $921 165 - - -
-
kWh
$921
165
MMBtu
-
-
$
06: 2.7444 CLOSE HOLES AND OPENINGS IN BUILDING SUCH AS BROKEN WINDOWS Savings:
$14,070
Cost:
-
- - $14,070 2,518 - - -
-
kWh
$14,070
2,518
MMBtu
-
-
$
TOTAL RECOMMENDED Savings:
$40,592
Cost:
$5,792
$25,967 171,747 $14,991 2,683 $(-366) - $25,967
171,747
kWh
$14,991
2,683
MMBtu
$(-366)
-
$
TOTAL IMPLEMENTED Savings:
$40,592
Cost:
$5,792
$25,967 171,747 $14,991 2,683 $(-366) - $25,967
171,747
kWh
$14,991
2,683
MMBtu
$(-366)
-
$
Savings
Cost
$ kWh $ MMBtu $ $
Electricity Usage Natural Gas Administrative Changes Electricity Usage Natural Gas Administrative Changes