Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
IAC Center San Diego State University
Assessment Year 1992
Principal Product TRANSPORTATION EQUIPMENT
NAICS n/a
SIC 3728 - Aircraft Parts And Equipment, Nec
Sales $10,000,000-$50,000,000
# of Employees 82
Plant Area (Sq.Ft.) 0
Annual Production 550 Pieces
Production Hrs. Annual 4,250
Location (State) CA
Source Yearly Cost Usage Unit Unit Cost
Electricity Usage $143,105 1,555,686 kWh $0.09
Natural Gas $10,384 1,623 MMBtu $6.40
TOTAL ENERGY COSTS $153,489
RECOMMENDED SAVINGS* $23,749 *Non-energy impacts
included in savings.
See recommendations below
IMPLEMENTED SAVINGS* -
#|Description Savings
Cost
Status Electricity Usage Natural Gas Administrative Changes Electricity Usage Natural Gas Administrative Changes
$ kWh $ MMBtu $ $
01: 2.4133 USE MOST EFFICIENT TYPE OF ELECTRIC MOTORS Savings:
$564
Cost:
$423
$564 6,155 - - - - $564
6,155
kWh
-
-
MMBtu
-
-
$
02: 2.6218 TURN OFF EQUIPMENT WHEN NOT IN USE Savings:
$5,920
Cost:
$505
$(-224) (-2,345) $6,144 960 - - $(-224)
(-2,345)
kWh
$6,144
960
MMBtu
-
-
$
03: 2.4322 USE OR REPLACE WITH ENERGY EFFICIENT SUBSTITUTES Savings:
$3,341
Cost:
$3,300
- - $3,341 522 - - -
-
kWh
$3,341
522
MMBtu
-
-
$
04: 2.2531 RE-SIZE CHARGING OPENINGS OR ADD MOVABLE COVER OR DOOR Savings:
$459
Cost:
$109
$459 4,982 - - - - $459
4,982
kWh
-
-
MMBtu
-
-
$
05: 2.7142 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS Savings:
$1,115
Cost:
$448
$883 9,672 - - $232 - $883
9,672
kWh
-
-
MMBtu
$232
-
$
06: 2.7111 REDUCE ILLUMINATION TO MINIMUM NECESSARY LEVELS Savings:
$12,350
Cost:
$30,068
$11,145 123,681 - - $1,205 - $11,145
123,681
kWh
-
-
MMBtu
$1,205
-
$
TOTAL RECOMMENDED Savings:
$23,749
Cost:
$34,853
$12,827 142,145 $9,485 1,482 $1,437 - $12,827
142,145
kWh
$9,485
1,482
MMBtu
$1,437
-
$
TOTAL IMPLEMENTED Savings:
-
Cost:
-
- - - - - - -
-
kWh
-
-
MMBtu
-
-
$
Savings
Cost
$ kWh $ MMBtu $ $
Electricity Usage Natural Gas Administrative Changes Electricity Usage Natural Gas Administrative Changes