Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
IAC Center San Diego State University
Assessment Year 1992
Principal Product FABRICATED METAL PRODUCT
NAICS n/a
SIC 3441 - Fabricated Structural Metal
Sales $50,000,000-$100,000,000
# of Employees 490
Plant Area (Sq.Ft.) 0
Annual Production 9,200 Pieces
Production Hrs. Annual 6,000
Location (State) CA
Source Yearly Cost Usage Unit Unit Cost
Electricity Usage $718,081 9,108,441 kWh $0.08
Natural Gas $58,056 11,942 MMBtu $4.86
TOTAL ENERGY COSTS $776,137
RECOMMENDED SAVINGS* $44,615 *Non-energy impacts
included in savings.
See recommendations below
IMPLEMENTED SAVINGS* $20,431
#|Description Savings
Cost
Status Electricity Usage Natural Gas Administrative Changes Electricity Usage Natural Gas Administrative Changes
$ kWh $ MMBtu $ $
01: 2.4133 USE MOST EFFICIENT TYPE OF ELECTRIC MOTORS Savings:
$1,880
Cost:
$1,817
$1,880 23,740 - - - - $1,880
23,740
kWh
-
-
MMBtu
-
-
$
02: 2.4236 ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES Savings:
$13,846
Cost:
$2,000
$13,846 175,557 - - - - $13,846
175,557
kWh
-
-
MMBtu
-
-
$
03: 2.4231 REDUCE THE PRESSURE OF COMPRESSED AIR TO THE MINIMUM REQUIRED Savings:
$591
Cost:
$15
$591 7,620 - - - - $591
7,620
kWh
-
-
MMBtu
-
-
$
04: 2.2514 COVER OPEN TANKS Savings:
$516
Cost:
$169
- - $516 106 - - -
-
kWh
$516
106
MMBtu
-
-
$
05: 2.1131 REPAIR FAULTY INSULATION IN FURNACES, BOILERS, ETC Savings:
$158
Cost:
$138
- - $158 33 - - -
-
kWh
$158
33
MMBtu
-
-
$
06: 2.2511 INSULATE BARE EQUIPMENT Savings:
$138
Cost:
$122
- - $138 28 - - -
-
kWh
$138
28
MMBtu
-
-
$
07: 2.7123 KEEP LAMPS AND REFLECTORS CLEAN Savings:
$24,184
Cost:
$51,124
$21,624 274,326 - - $2,560 - $21,624
274,326
kWh
-
-
MMBtu
$2,560
-
$
08: 2.7142 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS Savings:
$584
Cost:
$999
$355 4,396 - - $229 - $355
4,396
kWh
-
-
MMBtu
$229
-
$
09: 2.7142 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS Savings:
$1,496
Cost:
$2,200
$358 4,689 - - $1,138 - $358
4,689
kWh
-
-
MMBtu
$1,138
-
$
10: 2.7442 KEEP DOORS AND WINDOWS SHUT WHEN NOT ON USE Savings:
$1,222
Cost:
-
$1,222 15,533 - - - - $1,222
15,533
kWh
-
-
MMBtu
-
-
$
TOTAL RECOMMENDED Savings:
$44,615
Cost:
$58,584
$39,876 505,861 $812 167 $3,927 - $39,876
505,861
kWh
$812
167
MMBtu
$3,927
-
$
TOTAL IMPLEMENTED Savings:
$20,431
Cost:
$7,460
$18,252 231,535 $812 167 $1,367 - $18,252
231,535
kWh
$812
167
MMBtu
$1,367
-
$
Savings
Cost
$ kWh $ MMBtu $ $
Electricity Usage Natural Gas Administrative Changes Electricity Usage Natural Gas Administrative Changes