Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
IAC Center San Diego State University
Assessment Year 1992
Principal Product PLASTIC PLUMBING FIXTURE
NAICS n/a
SIC 3088 - Plastics Plumbing Fixtures
Sales $5,000,000-$10,000,000
# of Employees 100
Plant Area (Sq.Ft.) 0
Annual Production 24,350,000 Pieces
Production Hrs. Annual 6,120
Location (State) CA
Source Yearly Cost Usage Unit Unit Cost
Electricity Usage $170,988 2,009,965 kWh $0.09
Natural Gas $173 9 MMBtu $19.22
TOTAL ENERGY COSTS $171,161
RECOMMENDED SAVINGS* $10,853 *Non-energy impacts
included in savings.
See recommendations below
IMPLEMENTED SAVINGS* $8,553
#|Description Savings
Cost
Status Electricity Usage Administrative Changes Electricity Usage Administrative Changes
$ kWh $ $
01: 2.4133 USE MOST EFFICIENT TYPE OF ELECTRIC MOTORS Savings:
$2,402
Cost:
$1,720
$2,402 28,136 - - $2,402
28,136
kWh
-
-
$
02: 2.2511 INSULATE BARE EQUIPMENT Savings:
$3,784
Cost:
$206
$3,784 44,549 - - $3,784
44,549
kWh
-
-
$
03: 2.2511 INSULATE BARE EQUIPMENT Savings:
$189
Cost:
$18
$189 2,345 - - $189
2,345
kWh
-
-
$
04: 2.7142 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS Savings:
$141
Cost:
-
$200 2,345 $(-59) - $200
2,345
kWh
$(-59)
-
$
05: 2.7123 KEEP LAMPS AND REFLECTORS CLEAN Savings:
$2,111
Cost:
$2,300
$1,866 21,981 $245 - $1,866
21,981
kWh
$245
-
$
06: 2.7142 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS Savings:
$1,187
Cost:
$700
$457 5,275 $730 - $457
5,275
kWh
$730
-
$
07: 2.6232 INSTALL SET-BACK TIMERS Savings:
$1,039
Cost:
-
$923 10,844 $116 - $923
10,844
kWh
$116
-
$
TOTAL RECOMMENDED Savings:
$10,853
Cost:
$4,944
$9,821 115,475 $1,032 - $9,821
115,475
kWh
$1,032
-
$
TOTAL IMPLEMENTED Savings:
$8,553
Cost:
$2,626
$7,766 91,149 $787 - $7,766
91,149
kWh
$787
-
$
Savings
Cost
$ kWh $ $
Electricity Usage Administrative Changes Electricity Usage Administrative Changes