Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
IAC Center San Diego State University
Assessment Year 1992
Principal Product FIBROUS MATERIALS
NAICS n/a
SIC 3296 - Mineral Wool
Sales $10,000,000-$50,000,000
# of Employees 87
Plant Area (Sq.Ft.) 0
Annual Production 1,000,000 Pounds
Production Hrs. Annual 2,340
Location (State) CA
Source Yearly Cost Usage Unit Unit Cost
Electricity Usage $324,836 3,328,839 kWh $0.10
Natural Gas $267,760 72,937 MMBtu $3.67
TOTAL ENERGY COSTS $592,596
RECOMMENDED SAVINGS* $90,019 *Non-energy impacts
included in savings.
See recommendations below
IMPLEMENTED SAVINGS* $3,486
#|Description Savings
Cost
Status Electricity Usage Natural Gas Administrative Changes Electricity Usage Natural Gas Administrative Changes
$ kWh $ MMBtu $ $
01: 2.4133 USE MOST EFFICIENT TYPE OF ELECTRIC MOTORS Savings:
$943
Cost:
$4,020
$943 9,672 - - - - $943
9,672
kWh
-
-
MMBtu
-
-
$
02: 2.2426 USE WASTE HEAT FROM FLUE GASES TO HEAT SPACE CONDITIONING AIR Savings:
$64,662
Cost:
$30,000
- - $64,662 17,619 - - -
-
kWh
$64,662
17,619
MMBtu
-
-
$
03: 2.2414 USE WASTE HEAT FROM HOT FLUE GASES TO PREHEAT Savings:
$3,542
Cost:
$5,000
- - $3,542 965 - - -
-
kWh
$3,542
965
MMBtu
-
-
$
04: 2.2511 INSULATE BARE EQUIPMENT Savings:
$2,021
Cost:
$1,042
- - $2,021 551 - - -
-
kWh
$2,021
551
MMBtu
-
-
$
05: 2.2511 INSULATE BARE EQUIPMENT Savings:
$2,584
Cost:
$1,277
- - $2,584 704 - - -
-
kWh
$2,584
704
MMBtu
-
-
$
06: 2.4231 REDUCE THE PRESSURE OF COMPRESSED AIR TO THE MINIMUM REQUIRED Savings:
$566
Cost:
$20
$566 5,862 - - - - $566
5,862
kWh
-
-
MMBtu
-
-
$
07: 2.4111 UTILIZE ENERGY-EFFICIENT BELTS AND OTHER IMPROVED MECHANISMS Savings:
$1,110
Cost:
$2,205
$1,110 11,430 - - - - $1,110
11,430
kWh
-
-
MMBtu
-
-
$
08: 2.7142 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS Savings:
$1,977
Cost:
$1,740
$2,301 23,447 - - $(-324) - $2,301
23,447
kWh
-
-
MMBtu
$(-324)
-
$
09: 2.7123 KEEP LAMPS AND REFLECTORS CLEAN Savings:
$8,215
Cost:
$13,350
$6,600 72,978 - - $1,615 - $6,600
72,978
kWh
-
-
MMBtu
$1,615
-
$
10: 2.6232 INSTALL SET-BACK TIMERS Savings:
$3,085
Cost:
$2,867
$2,606 26,671 - - $479 - $2,606
26,671
kWh
-
-
MMBtu
$479
-
$
11: 2.7142 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS Savings:
$1,314
Cost:
$2,420
$543 5,569 - - $771 - $543
5,569
kWh
-
-
MMBtu
$771
-
$
TOTAL RECOMMENDED Savings:
$90,019
Cost:
$63,941
$14,669 155,629 $72,809 19,839 $2,541 - $14,669
155,629
kWh
$72,809
19,839
MMBtu
$2,541
-
$
TOTAL IMPLEMENTED Savings:
$3,486
Cost:
$5,780
$3,810 38,981 - - $(-324) - $3,810
38,981
kWh
-
-
MMBtu
$(-324)
-
$
Savings
Cost
$ kWh $ MMBtu $ $
Electricity Usage Natural Gas Administrative Changes Electricity Usage Natural Gas Administrative Changes