IAC logo
IAC Assessment: SD0119
Sponsored by:
DOE MESC
IAC logo
IAC Assessment: SD0119
Implementation Grant Funding Opportunity Open
IMPORTANT: The grant program operates on a rolling basis and applications may be submitted at any time, with quarterly reviews.
Learn More
Implementation Grant Funding Opportunity Open
Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
IAC Center San Diego State University
Assessment Year 1995
Principal Product Printed Circuit Boards
NAICS n/a
SIC 3672 - Printed Circuit Boards
Sales $5,000,000-$10,000,000
# of Employees 80
Plant Area (Sq.Ft.) 60,000
Annual Production 1,000,000 Thousand Feet
Production Hrs. Annual 6,552
Location (State) CA
Source Yearly Cost Usage Unit Unit Cost
Electricity Usage $174,346 1,856,682 kWh $0.09
Natural Gas $29,607 4,506 MMBtu $6.57
TOTAL ENERGY COSTS $222,841
RECOMMENDED SAVINGS* $47,566 *Non-energy impacts
included in savings.
See recommendations below
IMPLEMENTED SAVINGS* $24,283
#|Description Savings
Cost
Status Electricity Usage Natural Gas Other Liquid (haz) Solid Waste (non-haz) Electricity Usage Natural Gas Other Liquid (haz) Solid Waste (non-haz)
$ kWh $ MMBtu $ gal $ lb
01: 2.4133 USE MOST EFFICIENT TYPE OF ELECTRIC MOTORS Savings:
$5,107
Cost:
$4,150
$5,107 54,513 - - - - - - $5,107
54,513
kWh
-
-
MMBtu
-
-
gal
-
-
lb
02: 2.2511 INSULATE BARE EQUIPMENT Savings:
$4,410
Cost:
$4,925
- - $4,410 671 - - - - -
-
kWh
$4,410
671
MMBtu
-
-
gal
-
-
lb
03: 2.2136 INSTALL / REPAIR INSULATION ON STEAM LINES Savings:
$2,610
Cost:
$493
- - $2,610 397 - - - - -
-
kWh
$2,610
397
MMBtu
-
-
gal
-
-
lb
04: 2.4226 USE / PURCHASE OPTIMUM SIZED COMPRESSOR Savings:
$1,483
Cost:
$2,500
$1,483 15,826 - - - - - - $1,483
15,826
kWh
-
-
MMBtu
-
-
gal
-
-
lb
05: 2.2514 COVER OPEN TANKS Savings:
$593
Cost:
$227
- - $593 90 - - - - -
-
kWh
$593
90
MMBtu
-
-
gal
-
-
lb
06: 2.7142 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS Savings:
$5,196
Cost:
$8,381
$5,196 55,393 - - - - - - $5,196
55,393
kWh
-
-
MMBtu
-
-
gal
-
-
lb
07: 2.7144 INSTALL SPECTRAL REFLECTORS / DELAMP Savings:
$7,758
Cost:
$6,675
$7,758 76,202 - - - - - - $7,758
76,202
kWh
-
-
MMBtu
-
-
gal
-
-
lb
08: 2.7135 INSTALL OCCUPANCY SENSORS Savings:
$995
Cost:
$648
$995 9,672 - - - - - - $995
9,672
kWh
-
-
MMBtu
-
-
gal
-
-
lb
09: 2.7134 USE PHOTOCELL CONTROLS Savings:
$526
Cost:
$300
$526 5,569 - - - - - - $526
5,569
kWh
-
-
MMBtu
-
-
gal
-
-
lb
10: 3.6114 USE PRECIPITATING AGENTS IN WASTE WATER TREATMENT THAT PRODUCE THE LEAST QUANTITY OF WASTE Savings:
$17,352
Cost:
$7,000
- - - - $17,352 72,000 - - -
-
kWh
-
-
MMBtu
$17,352
72,000
gal
-
-
lb
11: 3.5248 SEPARATE AND RECYCLE SCRAP METAL TO FOUNDRY OR FOR SALE Savings:
$936
Cost:
-
- - - - - - $936 1,000 -
-
kWh
-
-
MMBtu
-
-
gal
$936
1,000
lb
12: 3.5212 REGRIND, REUSE, OR SELL SCRAP PLASTIC PARTS Savings:
$600
Cost:
-
- - - - - - $600 15,000 -
-
kWh
-
-
MMBtu
-
-
gal
$600
15,000
lb
TOTAL RECOMMENDED Savings:
$47,566
Cost:
$35,299
$21,065 217,175 $7,613 1,158 $17,352 72,000 $1,536 16,000 $21,065
217,175
kWh
$7,613
1,158
MMBtu
$17,352
72,000
gal
$1,536
16,000
lb
TOTAL IMPLEMENTED Savings:
$24,283
Cost:
$22,426
$19,544 201,934 $3,203 487 - - $1,536 16,000 $19,544
201,934
kWh
$3,203
487
MMBtu
-
-
gal
$1,536
16,000
lb
Savings
Cost
$ kWh $ MMBtu $ gal $ lb
Electricity Usage Natural Gas Other Liquid (haz) Solid Waste (non-haz) Electricity Usage Natural Gas Other Liquid (haz) Solid Waste (non-haz)