Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
IAC Center | San Diego State University |
---|---|
Assessment Year | 1996 |
Principal Product | Chrome Plated Pipes |
NAICS | n/a |
SIC | 3471 - Plating And Polishing |
Sales | $1,000,000-$5,000,000 |
# of Employees | 25 |
Plant Area (Sq.Ft.) | 50,000 |
Annual Production | 367,000,000 Pieces |
Production Hrs. Annual | 4,250 |
Location (State) | CA |
Source | Yearly Cost | Usage | Unit | Unit Cost |
---|---|---|---|---|
Electricity Usage | $286,811 | 5,418,816 | kWh | $0.05 |
Electricity Demand | $182,180 | 11,710 | kW-months/year | $15.56 |
Natural Gas | $10,581 | 1,369 | MMBtu | $7.73 |
TOTAL ENERGY COSTS | $497,634 | |||
RECOMMENDED SAVINGS* | $35,367 | *Non-energy impacts included in savings. See recommendations below |
||
IMPLEMENTED SAVINGS* | $35,367 |
#|Description |
Savings Cost |
Status | Electricity Usage | Water Disposal | Other Liquid (haz) | Electricity Usage | Water Disposal | Other Liquid (haz) | |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
$ | kWh | $ | Tgal | $ | gal | ||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
01: 2.4133 USE MOST EFFICIENT TYPE OF ELECTRIC MOTORS |
Savings: $4,050 Cost: $3,030 |
$4,050 | 49,531 | - | - | - | - |
$4,050 49,531 kWh |
- - Tgal |
- - gal |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
02: 2.4239 ELIMINATE OR REDUCE COMPRESSED AIR USAGE |
Savings: $7,102 Cost: $550 |
$7,102 | 98,183 | - | - | - | - |
$7,102 98,183 kWh |
- - Tgal |
- - gal |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
03: 2.7142 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS |
Savings: $3,180 Cost: $4,458 |
$3,180 | 26,671 | - | - | - | - |
$3,180 26,671 kWh |
- - Tgal |
- - gal |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
04: 2.7144 INSTALL SPECTRAL REFLECTORS / DELAMP |
Savings: $2,099 Cost: $2,480 |
$2,099 | 15,240 | - | - | - | - |
$2,099 15,240 kWh |
- - Tgal |
- - gal |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
05: 2.7135 INSTALL OCCUPANCY SENSORS |
Savings: $874 Cost: $410 |
$874 | 6,155 | - | - | - | - |
$874 6,155 kWh |
- - Tgal |
- - gal |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
06: 3.8136 SWITCH TO A SOLVENT THAT CAN BE CLEANED AND RE-USED |
Savings: $16,297 Cost: $1,450 |
- | - | - | - | $16,297 | 2,760 |
- - kWh |
- - Tgal |
$16,297 2,760 gal |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
07: 3.4113 TREAT AND REUSE RINSE WATERS |
Savings: $1,000 Cost: $280 |
- | - | $1,000 | 250,000 | - | - |
- - kWh |
$1,000 250,000 Tgal |
- - gal |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
08: 3.4113 TREAT AND REUSE RINSE WATERS |
Savings: $765 Cost: $200 |
- | - | $765 | 150,000 | - | - |
- - kWh |
$765 150,000 Tgal |
- - gal |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
TOTAL RECOMMENDED |
Savings: $35,367 Cost: $12,858 |
$17,305 | 195,780 | $1,765 | 400,000 | $16,297 | 2,760 | $17,305 195,780 kWh |
$1,765 400,000 Tgal |
$16,297 2,760 gal |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
TOTAL IMPLEMENTED |
Savings: $35,367 Cost: $12,858 |
$17,305 | 195,780 | $1,765 | 400,000 | $16,297 | 2,760 | $17,305 195,780 kWh |
$1,765 400,000 Tgal |
$16,297 2,760 gal |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
Savings Cost |
$ | kWh | $ | Tgal | $ | gal | |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
Electricity Usage | Water Disposal | Other Liquid (haz) | Electricity Usage | Water Disposal | Other Liquid (haz) |