Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
IAC Center | San Diego State University |
---|---|
Assessment Year | 1996 |
Principal Product | Cylinder Heads and Other Parts for Aircraft |
NAICS | n/a |
SIC | 3440 - |
Sales | $10,000,000-$50,000,000 |
# of Employees | 200 |
Plant Area (Sq.Ft.) | 70,000 |
Annual Production | 146,000 Pieces |
Production Hrs. Annual | 7,200 |
Location (State) | CA |
Source | Yearly Cost | Usage | Unit | Unit Cost |
---|---|---|---|---|
Electricity Usage | $338,705 | 4,708,382 | kWh | $0.07 |
Electricity Demand | $130,728 | 13,128 | kW-months/year | $9.96 |
Electricity Fees | $469,433 | - | $ | - |
Natural Gas | $97,661 | 22,706 | MMBtu | $4.30 |
TOTAL ENERGY COSTS | $1,088,186 | |||
RECOMMENDED SAVINGS* | $88,069 | *Non-energy impacts included in savings. See recommendations below |
||
IMPLEMENTED SAVINGS* | $88,069 |
#|Description |
Savings Cost |
Status | Electricity Usage | Electricity Demand | Other Liquid (non-haz) | Other Liquid (haz) | Administrative Changes | Electricity Usage | Electricity Demand | Other Liquid (non-haz) | Other Liquid (haz) | Administrative Changes | |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
$ | kWh | $ | kW-months/year | $ | gal | $ | gal | $ | $ | ||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
01: 2.4133 USE MOST EFFICIENT TYPE OF ELECTRIC MOTORS |
Savings: $4,983 Cost: $4,130 |
$4,983 | 53,927 | - | - | - | - | - | - | - | - |
$4,983 53,927 kWh |
- - kW-months/year |
- - gal |
- - gal |
- - $ |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
02: 2.4236 ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES |
Savings: $2,640 Cost: $350 |
- | - | $2,640 | 100 | - | - | - | - | - | - |
- - kWh |
$2,640 100 kW-months/year |
- - gal |
- - gal |
- - $ |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
03: 2.2614 USE COOLING TOWER OR ECONOMIZER TO REPLACE CHILLER COOLING |
Savings: $3,241 Cost: $4,860 |
$3,241 | 46,307 | - | - | - | - | - | - | - | - |
$3,241 46,307 kWh |
- - kW-months/year |
- - gal |
- - gal |
- - $ |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
04: 2.7142 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS |
Savings: $10,990 Cost: $11,477 |
- | - | $10,990 | 416 | - | - | - | - | - | - |
- - kWh |
$10,990 416 kW-months/year |
- - gal |
- - gal |
- - $ |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
05: 2.7144 INSTALL SPECTRAL REFLECTORS / DELAMP |
Savings: $8,674 Cost: $6,355 |
- | - | $8,674 | 320 | - | - | - | - | - | - |
- - kWh |
$8,674 320 kW-months/year |
- - gal |
- - gal |
- - $ |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
06: 2.7135 INSTALL OCCUPANCY SENSORS |
Savings: $582 Cost: $484 |
- | - | $582 | 17 | - | - | - | - | - | - |
- - kWh |
$582 17 kW-months/year |
- - gal |
- - gal |
- - $ |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
07: 3.1244 REDUCE SOLUTION DRAG-OUT TO PREVENT SOLUTION LOSS |
Savings: $26,348 Cost: - |
- | - | - | - | $26,348 | 1,090 | - | - | - | - |
- - kWh |
- - kW-months/year |
$26,348 1,090 gal |
- - gal |
- - $ |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
08: 3.6193 INSTALL EQUIPMENT (eg COMPACTOR) TO REDUCE DISPOSAL COSTS |
Savings: $5,300 Cost: $9,000 |
- | - | - | - | - | - | - | - | $5,300 | - |
- - kWh |
- - kW-months/year |
- - gal |
- - gal |
$5,300 - $ |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
09: 3.5131 RECYCLE WHITE WATER |
Savings: $7,791 Cost: $750 |
- | - | - | - | $7,791 | 3,150,000 | - | - | - | - |
- - kWh |
- - kW-months/year |
$7,791 3,150,000 gal |
- - gal |
- - $ |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
10: 3.3122 USE FILTRATION, CENTRIFUGING TO REMOVE CONTAMINANTS |
Savings: $17,520 Cost: - |
- | - | - | - | - | - | $17,520 | - | - | - |
- - kWh |
- - kW-months/year |
- - gal |
$17,520 - gal |
- - $ |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
TOTAL RECOMMENDED |
Savings: $88,069 Cost: $37,406 |
$8,224 | 100,234 | $22,886 | 853 | $34,139 | 3,151,090 | $17,520 | - | $5,300 | - | $8,224 100,234 kWh |
$22,886 853 kW-months/year |
$34,139 3,151,090 gal |
$17,520 - gal |
$5,300 - $ |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
TOTAL IMPLEMENTED |
Savings: $88,069 Cost: $37,406 |
$8,224 | 100,234 | $22,886 | 853 | $34,139 | 3,151,090 | $17,520 | - | $5,300 | - | $8,224 100,234 kWh |
$22,886 853 kW-months/year |
$34,139 3,151,090 gal |
$17,520 - gal |
$5,300 - $ |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
Savings Cost |
$ | kWh | $ | kW-months/year | $ | gal | $ | gal | $ | $ | |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
Electricity Usage | Electricity Demand | Other Liquid (non-haz) | Other Liquid (haz) | Administrative Changes | Electricity Usage | Electricity Demand | Other Liquid (non-haz) | Other Liquid (haz) | Administrative Changes |