Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
IAC Center | San Diego State University |
---|---|
Assessment Year | 1998 |
Principal Product | Steel Office Cabinets |
NAICS | n/a |
SIC | 2522 - Office Furniture, Except Wood |
Sales | $10,000,000-$50,000,000 |
# of Employees | 150 |
Plant Area (Sq.Ft.) | 120,000 |
Annual Production | 3,000,000 Pieces |
Production Hrs. Annual | 5,050 |
Location (State) | CA |
Source | Yearly Cost | Usage | Unit | Unit Cost |
---|---|---|---|---|
Electricity Usage | $159,168 | 2,339,390 | kWh | $0.07 |
Electricity Demand | $47,854 | 5,418 | kW-months/year | $8.83 |
Natural Gas | $116,715 | 21,392 | MMBtu | $5.46 |
TOTAL ENERGY COSTS | $323,737 | |||
RECOMMENDED SAVINGS* | $83,792 | *Non-energy impacts included in savings. See recommendations below |
||
IMPLEMENTED SAVINGS* | $11,093 |
#|Description |
Savings Cost |
Status | Electricity Usage | Electricity Demand | Natural Gas | Water Disposal | Solid Waste (non-haz) | Administrative Changes | Electricity Usage | Electricity Demand | Natural Gas | Water Disposal | Solid Waste (non-haz) | Administrative Changes | |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
$ | kWh | $ | kW-months/year | $ | MMBtu | $ | Tgal | $ | lb | $ | $ | ||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
01: 2.4133 USE MOST EFFICIENT TYPE OF ELECTRIC MOTORS |
Savings: $1,357 Cost: $3,530 |
$762 | 11,137 | $595 | 67 | - | - | - | - | - | - | - | - |
$762 11,137 kWh |
$595 67 kW-months/year |
- - MMBtu |
- - Tgal |
- - lb |
- - $ |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
02: 2.6218 TURN OFF EQUIPMENT WHEN NOT IN USE |
Savings: $1,716 Cost: - |
$1,319 | 19,343 | $397 | 45 | - | - | - | - | - | - | - | - |
$1,319 19,343 kWh |
$397 45 kW-months/year |
- - MMBtu |
- - Tgal |
- - lb |
- - $ |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
03: 2.2414 USE WASTE HEAT FROM HOT FLUE GASES TO PREHEAT |
Savings: $5,665 Cost: $1,180 |
- | - | - | - | $5,665 | 877 | - | - | - | - | - | - |
- - kWh |
- - kW-months/year |
$5,665 877 MMBtu |
- - Tgal |
- - lb |
- - $ |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
04: 2.4236 ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES |
Savings: $2,973 Cost: $500 |
$2,288 | 33,705 | $685 | 77 | - | - | - | - | - | - | - | - |
$2,288 33,705 kWh |
$685 77 kW-months/year |
- - MMBtu |
- - Tgal |
- - lb |
- - $ |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
05: 2.7142 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS |
Savings: $928 Cost: $1,853 |
$611 | 9,086 | $317 | 36 | - | - | - | - | - | - | - | - |
$611 9,086 kWh |
$317 36 kW-months/year |
- - MMBtu |
- - Tgal |
- - lb |
- - $ |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
06: 2.7144 INSTALL SPECTRAL REFLECTORS / DELAMP |
Savings: $2,785 Cost: $5,115 |
$1,768 | 22,567 | $1,017 | 115 | - | - | - | - | - | - | - | - |
$1,768 22,567 kWh |
$1,017 115 kW-months/year |
- - MMBtu |
- - Tgal |
- - lb |
- - $ |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
07: 3.2123 CONVERT TO HIGH VOLUME LOW PRESSURE (HVLP) PAINT GUNS |
Savings: $64,806 Cost: $732 |
- | - | - | - | - | - | - | - | $64,806 | 23,145 | - | - |
- - kWh |
- - kW-months/year |
- - MMBtu |
- - Tgal |
$64,806 23,145 lb |
- - $ |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
08: 3.6193 INSTALL EQUIPMENT (eg COMPACTOR) TO REDUCE DISPOSAL COSTS |
Savings: $3,050 Cost: $9,000 |
- | - | - | - | - | - | - | - | - | - | $3,050 | - |
- - kWh |
- - kW-months/year |
- - MMBtu |
- - Tgal |
- - lb |
$3,050 - $ |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
09: 3.4113 TREAT AND REUSE RINSE WATERS |
Savings: $512 Cost: $450 |
- | - | - | - | - | - | $512 | 587,071 | - | - | - | - |
- - kWh |
- - kW-months/year |
- - MMBtu |
$512 587,071 Tgal |
- - lb |
- - $ |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
TOTAL RECOMMENDED |
Savings: $83,792 Cost: $22,360 |
$6,748 | 95,838 | $3,011 | 340 | $5,665 | 877 | $512 | 587,071 | $64,806 | 23,145 | $3,050 | - | $6,748 95,838 kWh |
$3,011 340 kW-months/year |
$5,665 877 MMBtu |
$512 587,071 Tgal |
$64,806 23,145 lb |
$3,050 - $ |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
TOTAL IMPLEMENTED |
Savings: $11,093 Cost: $19,998 |
$5,429 | 76,495 | $2,614 | 295 | - | - | - | - | - | - | $3,050 | - | $5,429 76,495 kWh |
$2,614 295 kW-months/year |
- - MMBtu |
- - Tgal |
- - lb |
$3,050 - $ |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
Savings Cost |
$ | kWh | $ | kW-months/year | $ | MMBtu | $ | Tgal | $ | lb | $ | $ | |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
Electricity Usage | Electricity Demand | Natural Gas | Water Disposal | Solid Waste (non-haz) | Administrative Changes | Electricity Usage | Electricity Demand | Natural Gas | Water Disposal | Solid Waste (non-haz) | Administrative Changes |