Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
IAC Center | San Diego State University |
---|---|
Assessment Year | 1998 |
Principal Product | Commercial Refrigerants |
NAICS | n/a |
SIC | 2819 - Industrial Inorganic Chemicals, Nec |
Sales | $50,000,000-$100,000,000 |
# of Employees | 100 |
Plant Area (Sq.Ft.) | 1,000,000 |
Annual Production | 75,000,000 Pounds |
Production Hrs. Annual | 8,652 |
Location (State) | CA |
Source | Yearly Cost | Usage | Unit | Unit Cost |
---|---|---|---|---|
Electricity Usage | $563,423 | 12,332,063 | kWh | $0.05 |
Electricity Demand | $196,085 | 18,795 | kW-months/year | $10.43 |
Natural Gas | $5,700 | 705 | MMBtu | $8.09 |
TOTAL ENERGY COSTS | $765,208 | |||
RECOMMENDED SAVINGS* | $764,504 | *Non-energy impacts included in savings. See recommendations below |
||
IMPLEMENTED SAVINGS* | $33,200 |
#|Description |
Savings Cost |
Status | Electricity Usage | Electricity Demand | Natural Gas | Administrative Changes | Electricity Usage | Electricity Demand | Natural Gas | Administrative Changes | |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
$ | kWh | $ | kW-months/year | $ | MMBtu | $ | $ | ||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
01: 2.4133 USE MOST EFFICIENT TYPE OF ELECTRIC MOTORS |
Savings: $23,155 Cost: $22,250 |
$17,254 | 375,147 | $5,901 | 566 | - | - | - | - |
$17,254 375,147 kWh |
$5,901 566 kW-months/year |
- - MMBtu |
- - $ |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
02: 2.3415 USE A FOSSIL FUEL ENGINE TO COGENERATE ELECTRICITY OR MOTIVE POWER; AND UTILIZE HEAT |
Savings: $543,061 Cost: $1,420,250 |
$491,520 | 10,688,160 | $154,572 | 14,820 | $(-103,031) | (-121,128) | - | - |
$491,520 10,688,160 kWh |
$154,572 14,820 kW-months/year |
$(-103,031) (-121,128) MMBtu |
- - $ |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
03: 2.4146 USE ADJUSTABLE FREQUENCY DRIVE OR MULTIPLE SPEED MOTORS ON EXISTING SYSTEM |
Savings: $3,455 Cost: $6,625 |
$1,692 | 36,928 | $1,763 | 169 | - | - | - | - |
$1,692 36,928 kWh |
$1,763 169 kW-months/year |
- - MMBtu |
- - $ |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
04: 2.2515 USE OPTIMUM THICKNESS INSULATION |
Savings: $678 Cost: $219 |
$516 | 11,137 | $162 | 16 | - | - | - | - |
$516 11,137 kWh |
$162 16 kW-months/year |
- - MMBtu |
- - $ |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
05: 2.7142 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS |
Savings: $3,587 Cost: $5,358 |
$2,629 | 57,151 | $958 | 92 | - | - | - | - |
$2,629 57,151 kWh |
$958 92 kW-months/year |
- - MMBtu |
- - $ |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
06: 2.7144 INSTALL SPECTRAL REFLECTORS / DELAMP |
Savings: $4,788 Cost: $5,180 |
$2,786 | 60,668 | $2,002 | 192 | - | - | - | - |
$2,786 60,668 kWh |
$2,002 192 kW-months/year |
- - MMBtu |
- - $ |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
07: 3.6193 INSTALL EQUIPMENT (eg COMPACTOR) TO REDUCE DISPOSAL COSTS |
Savings: $5,780 Cost: $8,500 |
- | - | - | - | - | - | $5,780 | - |
- - kWh |
- - kW-months/year |
- - MMBtu |
$5,780 - $ |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
08: 2.1223 INSTALL SMALLER BOILER (INCREASE HIGH FIRE DUTY CYCLE) |
Savings: $180,000 Cost: $27,000 |
- | - | - | - | $180,000 | - | - | - |
- - kWh |
- - kW-months/year |
$180,000 - MMBtu |
- - $ |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
TOTAL RECOMMENDED |
Savings: $764,504 Cost: $1,495,382 |
$516,397 | 11,229,191 | $165,358 | 15,855 | $76,969 | (-121,128) | $5,780 | - | $516,397 11,229,191 kWh |
$165,358 15,855 kW-months/year |
$76,969 (-121,128) MMBtu |
$5,780 - $ |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
TOTAL IMPLEMENTED |
Savings: $33,200 Cost: $36,327 |
$20,399 | 443,435 | $7,021 | 674 | - | - | $5,780 | - | $20,399 443,435 kWh |
$7,021 674 kW-months/year |
- - MMBtu |
$5,780 - $ |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
Savings Cost |
$ | kWh | $ | kW-months/year | $ | MMBtu | $ | $ | |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||