IAC logo
IAC Assessment: SD0214
Sponsored by:
DOE MESC
IAC logo
IAC Assessment: SD0214
Implementation Grant Funding Opportunity Open
IMPORTANT: The grant program operates on a rolling basis and applications may be submitted at any time, with quarterly reviews.
Learn More
Implementation Grant Funding Opportunity Open
Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
IAC Center San Diego State University
Assessment Year 1999
Principal Product electronic components
NAICS n/a
SIC 3679 - Electronic Components, Nec
Sales $10,000,000-$50,000,000
# of Employees 50
Plant Area (Sq.Ft.) 35,000
Annual Production 0 Pieces
Production Hrs. Annual 4,400
Location (State) CA
Source Yearly Cost Usage Unit Unit Cost
Electricity Usage $67,333 1,305,393 kWh $0.05
Electricity Demand $66,845 4,136 kW-months/year $16.16
Natural Gas $83 10 MMBtu $8.30
TOTAL ENERGY COSTS $134,261
RECOMMENDED SAVINGS* $145,989 *Non-energy impacts
included in savings.
See recommendations below
IMPLEMENTED SAVINGS* $11,931
#|Description Savings
Cost
Status Electricity Usage Electricity Demand Natural Gas Administrative Changes Electricity Usage Electricity Demand Natural Gas Administrative Changes
$ kWh $ kW-months/year $ MMBtu $ $
01: 2.7144 INSTALL SPECTRAL REFLECTORS / DELAMP Savings:
$6,221
Cost:
$5,880
$3,315 64,185 $2,906 180 - - - - $3,315
64,185
kWh
$2,906
180
kW-months/year
-
-
MMBtu
-
-
$
02: 2.7142 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS Savings:
$4,699
Cost:
$10,196
$2,298 44,549 $2,401 149 - - - - $2,298
44,549
kWh
$2,401
149
kW-months/year
-
-
MMBtu
-
-
$
03: 2.4133 USE MOST EFFICIENT TYPE OF ELECTRIC MOTORS Savings:
$2,874
Cost:
$1,100
$1,186 22,860 $1,688 104 - - - - $1,186
22,860
kWh
$1,688
104
kW-months/year
-
-
MMBtu
-
-
$
04: 2.1311 REPLACE ELECTRICALLY-OPERATED EQUIPMENT WITH FOSSIL FUEL EQUIPMENT Savings:
$38,175
Cost:
$12,000
$23,871 462,778 $29,127 1,802 $(-14,823) (-1,858) - - $23,871
462,778
kWh
$29,127
1,802
kW-months/year
$(-14,823)
(-1,858)
MMBtu
-
-
$
05: 3.6192 USE A LESS EXPENSIVE METHOD OF WASTE REMOVAL Savings:
$800
Cost:
-
- - - - - - $800 - -
-
kWh
-
-
kW-months/year
-
-
MMBtu
$800
-
$
06: 3.6192 USE A LESS EXPENSIVE METHOD OF WASTE REMOVAL Savings:
$2,832
Cost:
$1,000
- - - - - - $2,832 - -
-
kWh
-
-
kW-months/year
-
-
MMBtu
$2,832
-
$
07: 3.4112 RECOVERY METALS FROM RINSE WATER(EVAP., ION EXCHANGE, RO, ELECTROLYSIS, ELECTRODIALYSIS) AND REUSE RINSE WATER Savings:
$3,600
Cost:
$2,300
- - - - - - $3,600 - -
-
kWh
-
-
kW-months/year
-
-
MMBtu
$3,600
-
$
08: 4.321 OPTIMIZE PRODUCTION LOT SIZES AND INVENTORIES Savings:
$86,788
Cost:
$60,000
- - - - - - $86,788 - -
-
kWh
-
-
kW-months/year
-
-
MMBtu
$86,788
-
$
TOTAL RECOMMENDED Savings:
$145,989
Cost:
$92,476
$30,670 594,372 $36,122 2,235 $(-14,823) (-1,858) $94,020 - $30,670
594,372
kWh
$36,122
2,235
kW-months/year
$(-14,823)
(-1,858)
MMBtu
$94,020
-
$
TOTAL IMPLEMENTED Savings:
$11,931
Cost:
$13,496
$2,298 44,549 $2,401 149 - - $7,232 - $2,298
44,549
kWh
$2,401
149
kW-months/year
-
-
MMBtu
$7,232
-
$
Savings
Cost
$ kWh $ kW-months/year $ MMBtu $ $
Electricity Usage Electricity Demand Natural Gas Administrative Changes Electricity Usage Electricity Demand Natural Gas Administrative Changes