Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
IAC Center | San Diego State University |
---|---|
Assessment Year | 1999 |
Principal Product | Transducers |
NAICS | n/a |
SIC | 3829 - Measuring & Controlling Devices, Nec |
Sales | $10,000,000-$50,000,000 |
# of Employees | 250 |
Plant Area (Sq.Ft.) | 68,500 |
Annual Production | 25,000 Pieces |
Production Hrs. Annual | 4,862 |
Location (State) | CA |
Source | Yearly Cost | Usage | Unit | Unit Cost |
---|---|---|---|---|
Electricity Usage | $213,211 | 3,053,927 | kWh | $0.07 |
Electricity Demand | $43,601 | 7,781 | kW-months/year | $5.60 |
Natural Gas | $943 | 138 | MMBtu | $6.83 |
TOTAL ENERGY COSTS | $260,980 | |||
RECOMMENDED SAVINGS* | $97,985 | *Non-energy impacts included in savings. See recommendations below |
||
IMPLEMENTED SAVINGS* | $15,203 |
#|Description |
Savings Cost |
Status | Electricity Usage | Electricity Demand | Gaseous Waste | Administrative Changes | Electricity Usage | Electricity Demand | Gaseous Waste | Administrative Changes | |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
$ | kWh | $ | kW-months/year | $ | lb | $ | $ | ||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
01: 2.7142 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS |
Savings: $14,410 Cost: $6,484 |
$12,190 | 174,678 | $2,220 | 397 | - | - | - | - |
$12,190 174,678 kWh |
$2,220 397 kW-months/year |
- - lb |
- - $ |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
02: 2.7228 AVOID INTRODUCING HOT, HUMID, OR DIRTY AIR INTO HVAC SYSTEM |
Savings: $5,156 Cost: $4,875 |
$3,579 | 51,290 | $1,577 | 282 | - | - | - | - |
$3,579 51,290 kWh |
$1,577 282 kW-months/year |
- - lb |
- - $ |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
03: 3.1191 CHANGE PROCEDURES / EQUIPMENT / OPERATING CONDITIONS |
Savings: $8,513 Cost: $16,000 |
- | - | - | - | $8,513 | 106,944 | - | - |
- - kWh |
- - kW-months/year |
$8,513 106,944 lb |
- - $ |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
04: 4.446 AUTOMATE FINISHING PROCESS |
Savings: $69,113 Cost: $11,500 |
- | - | - | - | - | - | $69,113 | - |
- - kWh |
- - kW-months/year |
- - lb |
$69,113 - $ |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
05: 4.821 PAY BILLS ON TIME TO AVOID LATE FEES |
Savings: $793 Cost: - |
- | - | - | - | - | - | $793 | - |
- - kWh |
- - kW-months/year |
- - lb |
$793 - $ |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
TOTAL RECOMMENDED |
Savings: $97,985 Cost: $38,859 |
$15,769 | 225,968 | $3,797 | 679 | $8,513 | 106,944 | $69,906 | - | $15,769 225,968 kWh |
$3,797 679 kW-months/year |
$8,513 106,944 lb |
$69,906 - $ |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
TOTAL IMPLEMENTED |
Savings: $15,203 Cost: $6,484 |
$12,190 | 174,678 | $2,220 | 397 | - | - | $793 | - | $12,190 174,678 kWh |
$2,220 397 kW-months/year |
- - lb |
$793 - $ |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
Savings Cost |
$ | kWh | $ | kW-months/year | $ | lb | $ | $ | |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
Electricity Usage | Electricity Demand | Gaseous Waste | Administrative Changes | Electricity Usage | Electricity Demand | Gaseous Waste | Administrative Changes |