Implementation Grant Funding Opportunity Open
IMPORTANT: The grant program operates on a rolling basis and applications may be submitted at any time, with quarterly reviews.
Learn More
Implementation Grant Funding Opportunity Open
Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
IAC Center | San Diego State University |
---|---|
Assessment Year | 2002 |
Principal Product | Pneumatic,hydraulic and fuel fittings |
NAICS | n/a |
SIC | 3494 - Valves And Pipe Fittings, Nec |
Sales | $50,000,000-$100,000,000 |
# of Employees | 400 |
Plant Area (Sq.Ft.) | 609,840 |
Annual Production | 0 Units |
Production Hrs. Annual | 6,732 |
Location (State) | CA |
Source | Yearly Cost | Usage | Unit | Unit Cost |
---|---|---|---|---|
Electricity Usage | $890,354 | 6,531,261 | kWh | $0.14 |
Electricity Demand | $55,946 | 7,146 | kW-months/year | $7.83 |
Electricity Fees | $5,546 | - | $ | - |
Natural Gas | $39,991 | 5,076 | MMBtu | $7.88 |
TOTAL ENERGY COSTS | $1,024,669 | |||
RECOMMENDED SAVINGS* | $283,081 | *Non-energy impacts included in savings. See recommendations below |
||
IMPLEMENTED SAVINGS* | $41,211 |
#|Description |
Savings Cost |
Status | Electricity Usage | Electricity Demand | Electricity Fees | Other Liquid (haz) | Solid Waste (non-haz) | Personnel Changes | Electricity Usage | Electricity Demand | Electricity Fees | Other Liquid (haz) | Solid Waste (non-haz) | Personnel Changes | |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
$ | kWh | $ | kW-months/year | $ | $ | $ | gal | $ | lb | $ | $ | ||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
01: 2.4236 ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES |
Savings: $6,881 Cost: $1,440 |
$5,221 | 62,981 | $1,660 | 112 | - | - | - | - | - | - | - | - |
$5,221 62,981 kWh |
$1,660 112 kW-months/year |
- - $ |
- - gal |
- - lb |
- - $ |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
02: 2.1311 REPLACE ELECTRICALLY-OPERATED EQUIPMENT WITH FOSSIL FUEL EQUIPMENT |
Savings: $51,269 Cost: $35,000 |
$33,485 | 403,920 | $17,784 | 1,200 | - | - | - | - | - | - | - | - |
$33,485 403,920 kWh |
$17,784 1,200 kW-months/year |
- - $ |
- - gal |
- - lb |
- - $ |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
03: 2.4239 ELIMINATE OR REDUCE COMPRESSED AIR USAGE |
Savings: $27,450 Cost: $20,000 |
$20,817 | 251,104 | $6,633 | 448 | - | - | - | - | - | - | - | - |
$20,817 251,104 kWh |
$6,633 448 kW-months/year |
- - $ |
- - gal |
- - lb |
- - $ |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
04: 2.3137 USE POWER DURING OFF-PEAK PERIODS |
Savings: $30,695 Cost: - |
- | - | $19,184 | 900 | $11,511 | - | - | - | - | - | - | - |
- - kWh |
$19,184 900 kW-months/year |
$11,511 - $ |
- - gal |
- - lb |
- - $ |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
05: 2.7145 INSTALL SKYLIGHTS |
Savings: $41,280 Cost: $31,500 |
- | - | $23,134 | 1,561 | $18,146 | - | - | - | - | - | - | - |
- - kWh |
$23,134 1,561 kW-months/year |
$18,146 - $ |
- - gal |
- - lb |
- - $ |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
06: 2.4322 USE OR REPLACE WITH ENERGY EFFICIENT SUBSTITUTES |
Savings: $13,283 Cost: $3,000 |
$10,073 | 170,214 | $3,210 | 408 | - | - | - | - | - | - | - | - |
$10,073 170,214 kWh |
$3,210 408 kW-months/year |
- - $ |
- - gal |
- - lb |
- - $ |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
07: 2.7135 INSTALL OCCUPANCY SENSORS |
Savings: $3,635 Cost: $2,800 |
$3,635 | 43,842 | - | - | - | - | - | - | - | - | - | - |
$3,635 43,842 kWh |
- - kW-months/year |
- - $ |
- - gal |
- - lb |
- - $ |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
08: 2.6218 TURN OFF EQUIPMENT WHEN NOT IN USE |
Savings: $20,169 Cost: $2,500 |
$15,249 | 186,112 | $4,920 | 332 | - | - | - | - | - | - | - | - |
$15,249 186,112 kWh |
$4,920 332 kW-months/year |
- - $ |
- - gal |
- - lb |
- - $ |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
09: 3.3131 USE EVAPORATION TO CONCENTRATE MATERIAL |
Savings: $6,810 Cost: $3,000 |
- | - | - | - | - | - | $6,810 | 15,680 | - | - | - | - |
- - kWh |
- - kW-months/year |
- - $ |
$6,810 15,680 gal |
- - lb |
- - $ |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
10: 3.3131 USE EVAPORATION TO CONCENTRATE MATERIAL |
Savings: $825 Cost: $1,500 |
- | - | - | - | - | - | - | - | $825 | - | - | - |
- - kWh |
- - kW-months/year |
- - $ |
- - gal |
$825 - lb |
- - $ |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
11: 4.445 INSTALL EQUIPMENT TO MOVE PRODUCT |
Savings: $80,784 Cost: $100,000 |
- | - | - | - | - | - | - | - | - | - | $80,784 | - |
- - kWh |
- - kW-months/year |
- - $ |
- - gal |
- - lb |
$80,784 - $ |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
TOTAL RECOMMENDED |
Savings: $283,081 Cost: $200,740 |
$88,480 | 1,118,173 | $76,525 | 4,961 | $29,657 | - | $6,810 | 15,680 | $825 | - | $80,784 | - | $88,480 1,118,173 kWh |
$76,525 4,961 kW-months/year |
$29,657 - $ |
$6,810 15,680 gal |
$825 - lb |
$80,784 - $ |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
TOTAL IMPLEMENTED |
Savings: $41,211 Cost: $4,240 |
$8,856 | 106,823 | $20,844 | 1,012 | $11,511 | - | - | - | - | - | - | - | $8,856 106,823 kWh |
$20,844 1,012 kW-months/year |
$11,511 - $ |
- - gal |
- - lb |
- - $ |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
Savings Cost |
$ | kWh | $ | kW-months/year | $ | $ | $ | gal | $ | lb | $ | $ | |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
Electricity Usage | Electricity Demand | Electricity Fees | Other Liquid (haz) | Solid Waste (non-haz) | Personnel Changes | Electricity Usage | Electricity Demand | Electricity Fees | Other Liquid (haz) | Solid Waste (non-haz) | Personnel Changes |