Implementation Grant Funding Opportunity Open
IMPORTANT: The grant program operates on a rolling basis and applications may be submitted at any time, with quarterly reviews.
Learn More
Implementation Grant Funding Opportunity Open
Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
IAC Center | San Diego State University |
---|---|
Assessment Year | 2009 |
Principal Product | Mayonnaise, Dressing, and Other Prepared Sauce Manufacturin |
NAICS | 311941 - Mayonnaise, Dressing, and Other Prepared Sauce Manufacturing |
SIC | 2035 - Pickles, Sauces, And Salad Dressings |
Sales | <$500,000 |
# of Employees | 400 |
Plant Area (Sq.Ft.) | 680,000 |
Annual Production | 700,000,000 Pounds |
Production Hrs. Annual | 3,250 |
Location (State) | CA |
Source | Yearly Cost | Usage | Unit | Unit Cost |
---|---|---|---|---|
Electricity Usage | $1,390,034 | 16,641,007 | kWh | $0.08 |
Electricity Demand | $532,051 | 33,909 | kW-months/year | $15.69 |
Electricity Fees | $11,682 | - | $ | - |
Natural Gas | $265,670 | 32,915 | MMBtu | $8.07 |
TOTAL ENERGY COSTS | $2,199,437 | |||
RECOMMENDED SAVINGS* | $157,663 | *Non-energy impacts included in savings. See recommendations below |
||
IMPLEMENTED SAVINGS* | $95,815 |
#|Description |
Savings Cost |
Status | Electricity Usage | Electricity Demand | Natural Gas | Electricity Usage | Electricity Demand | Natural Gas | |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
$ | kWh | $ | kW-months/year | $ | MMBtu | ||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
01: 2.7241 INSTALL OUTSIDE AIR DAMPER / ECONOMIZER ON HVAC UNIT |
Savings: $17,800 Cost: $10,000 |
$17,800 | 213,000 | - | - | - | - |
$17,800 213,000 kWh |
- - kW-months/year |
- - MMBtu |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
02: 2.4231 REDUCE THE PRESSURE OF COMPRESSED AIR TO THE MINIMUM REQUIRED |
Savings: $12,170 Cost: $1,000 |
$8,938 | 107,000 | $3,232 | 206 | - | - |
$8,938 107,000 kWh |
$3,232 206 kW-months/year |
- - MMBtu |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
03: 2.1243 USE HEAT FROM BOILER BLOWDOWN TO PREHEAT BOILER FEED WATER |
Savings: $7,840 Cost: $10,000 |
- | - | - | - | $7,840 | 937 |
- - kWh |
- - kW-months/year |
$7,840 937 MMBtu |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
04: 2.2121 INCREASE AMOUNT OF CONDENSATE RETURNED |
Savings: $15,940 Cost: $2,263 |
$15,940 | 328,250 | - | - | - | - |
$15,940 328,250 kWh |
- - kW-months/year |
- - MMBtu |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
05: 2.7142 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS |
Savings: $49,905 Cost: $161,162 |
$36,716 | 437,100 | $13,189 | 840 | - | - |
$36,716 437,100 kWh |
$13,189 840 kW-months/year |
- - MMBtu |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
06: 2.4146 USE ADJUSTABLE FREQUENCY DRIVE OR MULTIPLE SPEED MOTORS ON EXISTING SYSTEM |
Savings: $39,102 Cost: $50,136 |
$39,102 | 465,505 | - | - | - | - |
$39,102 465,505 kWh |
- - kW-months/year |
- - MMBtu |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
07: 2.7261 INSTALL TIMERS AND/OR THERMOSTATS |
Savings: $14,906 Cost: $500 |
$14,906 | 177,450 | - | - | - | - |
$14,906 177,450 kWh |
- - kW-months/year |
- - MMBtu |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
TOTAL RECOMMENDED |
Savings: $157,663 Cost: $235,061 |
$133,402 | 1,728,305 | $16,421 | 1,046 | $7,840 | 937 | $133,402 1,728,305 kWh |
$16,421 1,046 kW-months/year |
$7,840 937 MMBtu |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
TOTAL IMPLEMENTED |
Savings: $95,815 Cost: $174,425 |
$79,394 | 1,085,350 | $16,421 | 1,046 | - | - | $79,394 1,085,350 kWh |
$16,421 1,046 kW-months/year |
- - MMBtu |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
Savings Cost |
$ | kWh | $ | kW-months/year | $ | MMBtu | |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
Electricity Usage | Electricity Demand | Natural Gas | Electricity Usage | Electricity Demand | Natural Gas |