Implementation Grant Funding Opportunity Open
IMPORTANT: The grant program operates on a rolling basis and applications may be submitted at any time, with quarterly reviews.
Learn More
Implementation Grant Funding Opportunity Open
Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
IAC Center | San Diego State University |
---|---|
Assessment Year | 2009 |
Principal Product | COOKIES AND CRACKERS |
NAICS | 311821 - Cookie and Cracker Manufacturing |
SIC | 2052 - Cookies And Crackers |
Sales | <$500,000 |
# of Employees | 700 |
Plant Area (Sq.Ft.) | 150,000 |
Annual Production | 450 Units |
Production Hrs. Annual | 5,824 |
Location (State) | CA |
Source | Yearly Cost | Usage | Unit | Unit Cost |
---|---|---|---|---|
Electricity Usage | $754,508 | 8,447,220 | kWh | $0.09 |
Electricity Demand | $225,737 | 19,543 | kW-months/year | $11.55 |
Electricity Fees | $141 | - | $ | - |
Natural Gas | $566,911 | 59,831 | MMBtu | $9.48 |
TOTAL ENERGY COSTS | $1,547,297 | |||
RECOMMENDED SAVINGS* | $511,167 | *Non-energy impacts included in savings. See recommendations below |
||
IMPLEMENTED SAVINGS* | $49,401 |
#|Description |
Savings Cost |
Status | Electricity Usage | Electricity Demand | Natural Gas | Electricity Usage | Electricity Demand | Natural Gas | |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
$ | kWh | $ | kW-months/year | $ | MMBtu | ||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
01: 2.4146 USE ADJUSTABLE FREQUENCY DRIVE OR MULTIPLE SPEED MOTORS ON EXISTING SYSTEM |
Savings: $14,500 Cost: $6,463 |
$14,500 | 162,926 | - | - | - | - |
$14,500 162,926 kWh |
- - kW-months/year |
- - MMBtu |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
02: 2.1221 REPLACE OBSOLETE BURNERS WITH MORE EFFICIENT ONES |
Savings: $35,684 Cost: $50,000 |
- | - | - | - | $35,684 | 4,380 |
- - kWh |
- - kW-months/year |
$35,684 4,380 MMBtu |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
03: 2.2449 RECOVER HEAT FROM EXHAUSTED STEAM, HOT AIR OR HOT WATER |
Savings: $94,850 Cost: $12,450 |
- | - | - | - | $94,850 | 11,644 |
- - kWh |
- - kW-months/year |
$94,850 11,644 MMBtu |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
04: 2.3415 USE A FOSSIL FUEL ENGINE TO COGENERATE ELECTRICITY OR MOTIVE POWER; AND UTILIZE HEAT |
Savings: $269,651 Cost: $1,430,000 |
$269,651 | 8,760,000 | - | - | - | - |
$269,651 8,760,000 kWh |
- - kW-months/year |
- - MMBtu |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
05: 2.4236 ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES |
Savings: $13,149 Cost: $2,700 |
$13,149 | 147,741 | - | - | - | - |
$13,149 147,741 kWh |
- - kW-months/year |
- - MMBtu |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
06: 2.7142 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS |
Savings: $21,991 Cost: $16,630 |
$18,676 | 209,140 | $3,315 | 287 | - | - |
$18,676 209,140 kWh |
$3,315 287 kW-months/year |
- - MMBtu |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
07: 2.2622 REPLACE EXISTING CHILLER WITH HIGH EFFICIENCY MODEL |
Savings: $60,774 Cost: $175,800 |
$48,011 | 537,636 | $12,763 | 1,105 | - | - |
$48,011 537,636 kWh |
$12,763 1,105 kW-months/year |
- - MMBtu |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
08: 2.4133 USE MOST EFFICIENT TYPE OF ELECTRIC MOTORS |
Savings: $568 Cost: $1,444 |
$325 | 3,640 | $243 | 21 | - | - |
$325 3,640 kWh |
$243 21 kW-months/year |
- - MMBtu |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
TOTAL RECOMMENDED |
Savings: $511,167 Cost: $1,695,487 |
$364,312 | 9,821,083 | $16,321 | 1,413 | $130,534 | 16,024 | $364,312 9,821,083 kWh |
$16,321 1,413 kW-months/year |
$130,534 16,024 MMBtu |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
TOTAL IMPLEMENTED |
Savings: $49,401 Cost: $54,144 |
$13,474 | 151,381 | $243 | 21 | $35,684 | 4,380 | $13,474 151,381 kWh |
$243 21 kW-months/year |
$35,684 4,380 MMBtu |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
Savings Cost |
$ | kWh | $ | kW-months/year | $ | MMBtu | |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
Electricity Usage | Electricity Demand | Natural Gas | Electricity Usage | Electricity Demand | Natural Gas |