Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
IAC Center | San Diego State University |
---|---|
Assessment Year | 2014 |
Principal Product | composite layup tooling |
NAICS | 333514 - Special Die and Tool, Die Set, Jig, and Fixture Manufacturing |
SIC | 3544 - Special Dies, Tools, Jigs & Fixtures |
Sales | $50,000,000-$100,000,000 |
# of Employees | 65 |
Plant Area (Sq.Ft.) | 24,000 |
Annual Production | 10,000 Pieces |
Production Hrs. Annual | 7,488 |
Location (State) | CA |
Source | Yearly Cost | Usage | Unit | Unit Cost |
---|---|---|---|---|
Electricity Usage | $201,492 | 2,852,641 | kWh | $0.07 |
Electricity Demand | $292,673 | 14,579 | kW-months/year | $20.07 |
Electricity Fees | $43,766 | - | $ | - |
Natural Gas | $57,296 | 9,228 | MMBtu | $6.21 |
TOTAL ENERGY COSTS | $595,227 | |||
RECOMMENDED SAVINGS* | $196,589 | *Non-energy impacts included in savings. See recommendations below |
||
IMPLEMENTED SAVINGS* | $79,501 |
#|Description |
Savings Cost |
Status | Electricity Usage | Electricity Demand | Natural Gas | Electricity Usage | Electricity Demand | Natural Gas | |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
$ | kWh | $ | kW-months/year | $ | MMBtu | ||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
01: 2.1311 REPLACE ELECTRICALLY-OPERATED EQUIPMENT WITH FOSSIL FUEL EQUIPMENT |
Savings: $117,088 Cost: $25,225 |
$2,376 | 33,657 | $115,603 | 5,760 | $(-891) | (-144) |
$2,376 33,657 kWh |
$115,603 5,760 kW-months/year |
$(-891) (-144) MMBtu |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
02: 2.3131 RESCHEDULE PLANT OPERATIONS OR REDUCE LOAD TO AVOID PEAKS |
Savings: $31,720 Cost: $5,000 |
- | - | $31,720 | 2,278 | - | - |
- - kWh |
$31,720 2,278 kW-months/year |
- - MMBtu |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
03: 2.7232 REPLACE EXISTING HVAC UNIT WITH HIGH EFFICIENCY MODEL |
Savings: $25,053 Cost: $91,900 |
$19,992 | 283,173 | $5,061 | 252 | - | - |
$19,992 283,173 kWh |
$5,061 252 kW-months/year |
- - MMBtu |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
04: 2.7425 CLEAN OR COLOR ROOF TO REDUCE SOLAR LOAD |
Savings: $13,807 Cost: $28,125 |
$10,702 | 151,589 | $3,105 | 155 | - | - |
$10,702 151,589 kWh |
$3,105 155 kW-months/year |
- - MMBtu |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
05: 2.4236 ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES |
Savings: $5,114 Cost: $1,000 |
$3,681 | 52,137 | $1,433 | 71 | - | - |
$3,681 52,137 kWh |
$1,433 71 kW-months/year |
- - MMBtu |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
06: 2.7134 USE PHOTOCELL CONTROLS |
Savings: $1,975 Cost: $5,550 |
$1,390 | 19,701 | $585 | 29 | - | - |
$1,390 19,701 kWh |
$585 29 kW-months/year |
- - MMBtu |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
07: 2.4133 USE MOST EFFICIENT TYPE OF ELECTRIC MOTORS |
Savings: $1,832 Cost: $4,400 |
$1,200 | 17,001 | $632 | 32 | - | - |
$1,200 17,001 kWh |
$632 32 kW-months/year |
- - MMBtu |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
TOTAL RECOMMENDED |
Savings: $196,589 Cost: $161,200 |
$39,341 | 557,258 | $158,139 | 8,577 | $(-891) | (-144) | $39,341 557,258 kWh |
$158,139 8,577 kW-months/year |
$(-891) (-144) MMBtu |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
TOTAL IMPLEMENTED |
Savings: $79,501 Cost: $135,975 |
$36,965 | 523,601 | $42,536 | 2,817 | - | - | $36,965 523,601 kWh |
$42,536 2,817 kW-months/year |
- - MMBtu |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
Savings Cost |
$ | kWh | $ | kW-months/year | $ | MMBtu | |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
Electricity Usage | Electricity Demand | Natural Gas | Electricity Usage | Electricity Demand | Natural Gas |