Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
IAC Center San Diego State University
Assessment Year 2011
Principal Product Office and Store Fixtures
NAICS 337215 - Showcase, Partition, Shelving, and Locker Manufacturing
SIC 2542 - Partitions And Fixtures, Except Wood
Sales $10,000,000-$50,000,000
# of Employees 110
Plant Area (Sq.Ft.) 184,000
Annual Production 1,000,000 Units
Production Hrs. Annual 2,080
Location (State) CA
Source Yearly Cost Usage Unit Unit Cost
Electricity Usage $89,206 899,565 kWh $0.10
Electricity Demand $67,159 5,272 kW-months/year $12.74
Natural Gas $82,873 12,344 MMBtu $6.71
TOTAL ENERGY COSTS $239,238
RECOMMENDED SAVINGS* $22,303 *Non-energy impacts
included in savings.
See recommendations below
IMPLEMENTED SAVINGS* $667
#|Description Savings
Cost
Status Electricity Usage Electricity Demand Natural Gas Electricity Usage Electricity Demand Natural Gas
$ kWh $ kW-months/year $ MMBtu
01: 2.7134 USE PHOTOCELL CONTROLS Savings:
$152
Cost:
-
$87 881 $65 5 - - $87
881
kWh
$65
5
kW-months/year
-
-
MMBtu
02: 2.7447 INSTALL VINYL STRIP / HIGH SPEED / AIR CURTAIN DOORS Savings:
$11,615
Cost:
$5,000
$(-423) (-4,267) - - $12,038 8,965 $(-423)
(-4,267)
kWh
-
-
kW-months/year
$12,038
8,965
MMBtu
03: 2.4239 ELIMINATE OR REDUCE COMPRESSED AIR USAGE Savings:
$3,820
Cost:
$2,500
$3,820 38,470 - - - - $3,820
38,470
kWh
-
-
kW-months/year
-
-
MMBtu
04: 2.2123 INSULATE FEEDWATER TANK Savings:
$443
Cost:
$400
$443 66 - - - - $443
66
kWh
-
-
kW-months/year
-
-
MMBtu
05: 2.2614 USE COOLING TOWER OR ECONOMIZER TO REPLACE CHILLER COOLING Savings:
$5,758
Cost:
$7,385
$5,758 58,040 - - - - $5,758
58,040
kWh
-
-
kW-months/year
-
-
MMBtu
06: 2.7142 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS Savings:
$515
Cost:
$983
$296 2,979 $219 17 - - $296
2,979
kWh
$219
17
kW-months/year
-
-
MMBtu
TOTAL RECOMMENDED Savings:
$22,303
Cost:
$16,268
$9,981 96,169 $284 22 $12,038 8,965 $9,981
96,169
kWh
$284
22
kW-months/year
$12,038
8,965
MMBtu
TOTAL IMPLEMENTED Savings:
$667
Cost:
$983
$383 3,860 $284 22 - - $383
3,860
kWh
$284
22
kW-months/year
-
-
MMBtu
Savings
Cost
$ kWh $ kW-months/year $ MMBtu
Electricity Usage Electricity Demand Natural Gas Electricity Usage Electricity Demand Natural Gas