Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
IAC Center San Diego State University
Assessment Year 2016
Principal Product High Performance Catalysts and Resins, Research and Development
NAICS 325180 - Other Basic Inorganic Chemical Manufacturing
SIC 2819 - Industrial Inorganic Chemicals, Nec
Sales $10,000,000-$50,000,000
# of Employees 110
Plant Area (Sq.Ft.) 65,000
Annual Production 11,000 Pounds
Production Hrs. Annual 3,900
Location (State) CA
Source Yearly Cost Usage Unit Unit Cost
Electricity Usage $203,943 1,748,230 kWh $0.12
Electricity Demand $65,108 4,610 kW-months/year $14.12
Electricity Fees $63,626 - $ -
Natural Gas $14,268 1,826 MMBtu $7.81
TOTAL ENERGY COSTS $346,945
RECOMMENDED SAVINGS* $78,797 *Non-energy impacts
included in savings.
See recommendations below
IMPLEMENTED SAVINGS* $7,718
#|Description Savings
Cost
Status Electricity Usage Electricity Demand Electricity Fees Electricity Usage Electricity Demand Electricity Fees
$ kWh $ kW-months/year $ $
01: 2.7232 REPLACE EXISTING HVAC UNIT WITH HIGH EFFICIENCY MODEL Savings:
$23,109
Cost:
$108,180
$16,290 139,589 $6,819 483 - - $16,290
139,589
kWh
$6,819
483
kW-months/year
-
-
$
02: 2.7491 INSULATE GLAZING, WALLS, CEILINGS, AND ROOFS Savings:
$21,873
Cost:
$21,829
$18,258 156,455 $3,615 256 - - $18,258
156,455
kWh
$3,615
256
kW-months/year
-
-
$
03: 2.3212 OPTIMIZE PLANT POWER FACTOR Savings:
$10,293
Cost:
$10,000
- - - - $10,293 - -
-
kWh
-
-
kW-months/year
$10,293
-
$
04: 2.7121 UTILIZE DAYLIGHT WHENEVER POSSIBLE IN LIEU OF ARTIFICIAL LIGHT Savings:
$9,320
Cost:
$22,960
$5,980 51,249 $3,340 237 - - $5,980
51,249
kWh
$3,340
237
kW-months/year
-
-
$
05: 2.7142 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS Savings:
$6,406
Cost:
$10,314
$4,387 37,588 $2,019 143 - - $4,387
37,588
kWh
$2,019
143
kW-months/year
-
-
$
06: 2.7423 REDUCE HEAT GAIN BY WINDOW TINTING Savings:
$2,089
Cost:
$7,880
$1,657 14,203 $432 31 - - $1,657
14,203
kWh
$432
31
kW-months/year
-
-
$
07: 2.4131 SIZE ELECTRIC MOTORS FOR PEAK OPERATING EFFICIENCY Savings:
$1,758
Cost:
$5,550
$1,281 10,982 $477 34 - - $1,281
10,982
kWh
$477
34
kW-months/year
-
-
$
08: 2.7134 USE PHOTOCELL CONTROLS Savings:
$1,432
Cost:
$4,070
$1,337 11,450 $95 7 - - $1,337
11,450
kWh
$95
7
kW-months/year
-
-
$
09: 2.7135 INSTALL OCCUPANCY SENSORS Savings:
$1,312
Cost:
$3,610
$1,312 11,240 - - - - $1,312
11,240
kWh
-
-
kW-months/year
-
-
$
10: 2.7312 MINIMIZE USE OF OUTSIDE MAKE-UP AIR FOR VENTILATION EXCEPT WHEN USED FOR ECONOMIZER CYCLE Savings:
$1,205
Cost:
$2,550
$928 7,954 $277 20 - - $928
7,954
kWh
$277
20
kW-months/year
-
-
$
TOTAL RECOMMENDED Savings:
$78,797
Cost:
$196,943
$51,430 440,710 $17,074 1,210 $10,293 - $51,430
440,710
kWh
$17,074
1,210
kW-months/year
$10,293
-
$
TOTAL IMPLEMENTED Savings:
$7,718
Cost:
$13,924
$5,699 48,828 $2,019 143 - - $5,699
48,828
kWh
$2,019
143
kW-months/year
-
-
$
Savings
Cost
$ kWh $ kW-months/year $ $
Electricity Usage Electricity Demand Electricity Fees Electricity Usage Electricity Demand Electricity Fees