Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
IAC Center San Diego State University
Assessment Year 2018
Principal Product Coatings
NAICS 332812 - Metal Coating, Engraving (except Jewelry and Silverware), and Allied Services to Manufacturers
SIC 3479 - Metal Coating And Allied Services
Sales $10,000,000-$50,000,000
# of Employees 160
Plant Area (Sq.Ft.) 26,000
Annual Production 400,000,000 Units
Production Hrs. Annual 5,202
Location (State) CA
Source Yearly Cost Usage Unit Unit Cost
Electricity Usage $188,512 2,390,069 kWh $0.08
Electricity Demand $119,402 5,553 kW-months/year $21.50
Electricity Fees $8,779 - $ -
Natural Gas $30,963 4,184 MMBtu $7.40
TOTAL ENERGY COSTS $347,656
RECOMMENDED SAVINGS* $30,511 *Non-energy impacts
included in savings.
See recommendations below
IMPLEMENTED SAVINGS* $30,511
#|Description Savings
Cost
Status Electricity Usage Electricity Demand Ancillary Material Cost Electricity Usage Electricity Demand Ancillary Material Cost
$ kWh $ kW-months/year $ $
01: 2.3132 RECHARGE BATTERIES ON DURING OFF-PEAK DEMAND PERIODS Savings:
$14,519
Cost:
$67,626
$3,396 43,050 $11,123 517 - - $3,396
43,050
kWh
$11,123
517
kW-months/year
-
-
$
02: 2.7142 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS Savings:
$8,784
Cost:
$5,838
$5,217 66,114 $3,476 162 $91 - $5,217
66,114
kWh
$3,476
162
kW-months/year
$91
-
$
03: 2.4146 USE ADJUSTABLE FREQUENCY DRIVE OR MULTIPLE SPEED MOTORS ON EXISTING SYSTEM Savings:
$4,330
Cost:
$10,000
$2,425 30,734 $1,905 89 - - $2,425
30,734
kWh
$1,905
89
kW-months/year
-
-
$
04: 2.4231 REDUCE THE PRESSURE OF COMPRESSED AIR TO THE MINIMUM REQUIRED Savings:
$1,699
Cost:
$900
$1,699 21,538 - - - - $1,699
21,538
kWh
-
-
kW-months/year
-
-
$
05: 2.7134 USE PHOTOCELL CONTROLS Savings:
$1,115
Cost:
$2,775
$1,115 14,136 - - - - $1,115
14,136
kWh
-
-
kW-months/year
-
-
$
06: 2.7135 INSTALL OCCUPANCY SENSORS Savings:
$64
Cost:
$63
$64 815 - - - - $64
815
kWh
-
-
kW-months/year
-
-
$
TOTAL RECOMMENDED Savings:
$30,511
Cost:
$87,202
$13,916 176,387 $16,504 767 $91 - $13,916
176,387
kWh
$16,504
767
kW-months/year
$91
-
$
TOTAL IMPLEMENTED Savings:
$30,511
Cost:
$87,202
$13,916 176,387 $16,504 767 $91 - $13,916
176,387
kWh
$16,504
767
kW-months/year
$91
-
$
Savings
Cost
$ kWh $ kW-months/year $ $
Electricity Usage Electricity Demand Ancillary Material Cost Electricity Usage Electricity Demand Ancillary Material Cost