Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
IAC Center San Francisco State University
Assessment Year 1994
Principal Product Candy
NAICS n/a
SIC 2064 - Candy & Other Confectionery Products
Sales $10,000,000-$50,000,000
# of Employees 250
Plant Area (Sq.Ft.) 160,000
Annual Production 35,000,000 Pounds
Production Hrs. Annual 4,358
Location (State) CA
Source Yearly Cost Usage Unit Unit Cost
Electricity Usage $374,011 3,458,675 kWh $0.11
Natural Gas $401,351 103,532 MMBtu $3.88
TOTAL ENERGY COSTS $775,362
RECOMMENDED SAVINGS* $339,012 *Non-energy impacts
included in savings.
See recommendations below
IMPLEMENTED SAVINGS* $30,357
#|Description Savings
Cost
Status Electricity Usage Natural Gas Administrative Changes Electricity Usage Natural Gas Administrative Changes
$ kWh $ MMBtu $ $
01: 2.4133 USE MOST EFFICIENT TYPE OF ELECTRIC MOTORS Savings:
$16,431
Cost:
$11,437
$16,431 152,110 - - - - $16,431
152,110
kWh
-
-
MMBtu
-
-
$
02: 2.7142 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS Savings:
$6,920
Cost:
$9,089
$6,920 64,185 - - - - $6,920
64,185
kWh
-
-
MMBtu
-
-
$
03: 2.7135 INSTALL OCCUPANCY SENSORS Savings:
$3,335
Cost:
$1,851
$3,335 30,774 - - - - $3,335
30,774
kWh
-
-
MMBtu
-
-
$
04: 2.1233 ANALYZE FLUE GAS FOR PROPER AIR/FUEL RATIO Savings:
$7,006
Cost:
-
- - $7,006 1,808 - - -
-
kWh
$7,006
1,808
MMBtu
-
-
$
05: 2.3417 USE WASTE HEAT WITH A CLOSED-CYCLE GAS TURBINE-GENERATOR SET TO COGENERATE ELECTRICITY AND HEAT Savings:
$305,320
Cost:
$1,140,000
- - - - $305,320 - -
-
kWh
-
-
MMBtu
$305,320
-
$
TOTAL RECOMMENDED Savings:
$339,012
Cost:
$1,162,377
$26,686 247,069 $7,006 1,808 $305,320 - $26,686
247,069
kWh
$7,006
1,808
MMBtu
$305,320
-
$
TOTAL IMPLEMENTED Savings:
$30,357
Cost:
$20,526
$23,351 216,295 $7,006 1,808 - - $23,351
216,295
kWh
$7,006
1,808
MMBtu
-
-
$
Savings
Cost
$ kWh $ MMBtu $ $
Electricity Usage Natural Gas Administrative Changes Electricity Usage Natural Gas Administrative Changes