Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
IAC Center | San Francisco State University |
---|---|
Assessment Year | 1995 |
Principal Product | Adhesives, Glue, and Gummed Paper Tape |
NAICS | n/a |
SIC | 2891 - Adhesives And Sealants |
Sales | $5,000,000-$10,000,000 |
# of Employees | 30 |
Plant Area (Sq.Ft.) | 45,000 |
Annual Production | 9,000 Thousand Feet |
Production Hrs. Annual | 2,750 |
Location (State) | CA |
Source | Yearly Cost | Usage | Unit | Unit Cost |
---|---|---|---|---|
Electricity Usage | $61,699 | 529,601 | kWh | $0.12 |
Natural Gas | $42,527 | 6,853 | MMBtu | $6.21 |
TOTAL ENERGY COSTS | $104,226 | |||
RECOMMENDED SAVINGS* | $35,275 | *Non-energy impacts included in savings. See recommendations below |
||
IMPLEMENTED SAVINGS* | $33,272 |
#|Description |
Savings Cost |
Status | Electricity Usage | Natural Gas | Water Disposal | Other Liquid (non-haz) | Solid Waste (non-haz) | Administrative Changes | Electricity Usage | Natural Gas | Water Disposal | Other Liquid (non-haz) | Solid Waste (non-haz) | Administrative Changes | |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
$ | kWh | $ | MMBtu | $ | Tgal | $ | gal | $ | lb | $ | $ | ||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
01: 2.4133 USE MOST EFFICIENT TYPE OF ELECTRIC MOTORS |
Savings: $282 Cost: $364 |
$282 | 2,345 | - | - | - | - | - | - | - | - | - | - |
$282 2,345 kWh |
- - MMBtu |
- - Tgal |
- - gal |
- - lb |
- - $ |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
02: 2.6218 TURN OFF EQUIPMENT WHEN NOT IN USE |
Savings: $314 Cost: $870 |
$314 | 2,638 | - | - | - | - | - | - | - | - | - | - |
$314 2,638 kWh |
- - MMBtu |
- - Tgal |
- - gal |
- - lb |
- - $ |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
03: 2.6218 TURN OFF EQUIPMENT WHEN NOT IN USE |
Savings: $359 Cost: - |
$359 | 2,931 | - | - | - | - | - | - | - | - | - | - |
$359 2,931 kWh |
- - MMBtu |
- - Tgal |
- - gal |
- - lb |
- - $ |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
04: 2.4111 UTILIZE ENERGY-EFFICIENT BELTS AND OTHER IMPROVED MECHANISMS |
Savings: $878 Cost: $618 |
$878 | 7,620 | - | - | - | - | - | - | - | - | - | - |
$878 7,620 kWh |
- - MMBtu |
- - Tgal |
- - gal |
- - lb |
- - $ |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
05: 2.2437 RECOVER WASTE HEAT FROM EQUIPMENT |
Savings: $1,449 Cost: $3,504 |
- | - | $1,449 | 233 | - | - | - | - | - | - | - | - |
- - kWh |
$1,449 233 MMBtu |
- - Tgal |
- - gal |
- - lb |
- - $ |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
06: 2.2121 INCREASE AMOUNT OF CONDENSATE RETURNED |
Savings: $2,272 Cost: $2,605 |
- | - | $659 | 106 | $1,613 | 250,175 | - | - | - | - | - | - |
- - kWh |
$659 106 MMBtu |
$1,613 250,175 Tgal |
- - gal |
- - lb |
- - $ |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
07: 2.4236 ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES |
Savings: $486 Cost: $100 |
$486 | 4,103 | - | - | - | - | - | - | - | - | - | - |
$486 4,103 kWh |
- - MMBtu |
- - Tgal |
- - gal |
- - lb |
- - $ |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
08: 2.4239 ELIMINATE OR REDUCE COMPRESSED AIR USAGE |
Savings: $554 Cost: $582 |
$554 | 4,689 | - | - | - | - | - | - | - | - | - | - |
$554 4,689 kWh |
- - MMBtu |
- - Tgal |
- - gal |
- - lb |
- - $ |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
09: 2.1311 REPLACE ELECTRICALLY-OPERATED EQUIPMENT WITH FOSSIL FUEL EQUIPMENT |
Savings: $6,885 Cost: $587 |
$8,911 | 76,495 | $(-2,026) | (-326) | - | - | - | - | - | - | - | - |
$8,911 76,495 kWh |
$(-2,026) (-326) MMBtu |
- - Tgal |
- - gal |
- - lb |
- - $ |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
10: 3.5143 RETURN SPENT SOLUTIONS TO THE MANUFACTURER |
Savings: $2,823 Cost: $50 |
- | - | - | - | - | - | $2,823 | 3,125 | - | - | - | - |
- - kWh |
- - MMBtu |
- - Tgal |
$2,823 3,125 gal |
- - lb |
- - $ |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
11: 3.4155 METER WASTE WATER |
Savings: $676 Cost: $2,700 |
- | - | - | - | - | - | - | - | - | - | $676 | - |
- - kWh |
- - MMBtu |
- - Tgal |
- - gal |
- - lb |
$676 - $ |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
12: 3.5217 REUSE / RECYCLE/ SELL PAPER PRODUCTS |
Savings: $12,953 Cost: $16,050 |
- | - | - | - | - | - | - | - | $12,953 | 151,200 | - | - |
- - kWh |
- - MMBtu |
- - Tgal |
- - gal |
$12,953 151,200 lb |
- - $ |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
13: 3.5311 RECOVER AND REUSE WASTE MATERIAL |
Savings: $5,344 Cost: $4,584 |
- | - | - | - | - | - | - | - | $5,344 | 3,600 | - | - |
- - kWh |
- - MMBtu |
- - Tgal |
- - gal |
$5,344 3,600 lb |
- - $ |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
TOTAL RECOMMENDED |
Savings: $35,275 Cost: $32,614 |
$11,784 | 100,821 | $82 | 13 | $1,613 | 250,175 | $2,823 | 3,125 | $18,297 | 154,800 | $676 | - | $11,784 100,821 kWh |
$82 13 MMBtu |
$1,613 250,175 Tgal |
$2,823 3,125 gal |
$18,297 154,800 lb |
$676 - $ |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
TOTAL IMPLEMENTED |
Savings: $33,272 Cost: $28,528 |
$11,230 | 96,132 | $(-1,367) | (-220) | $1,613 | 250,175 | $2,823 | 3,125 | $18,297 | 154,800 | $676 | - | $11,230 96,132 kWh |
$(-1,367) (-220) MMBtu |
$1,613 250,175 Tgal |
$2,823 3,125 gal |
$18,297 154,800 lb |
$676 - $ |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
Savings Cost |
$ | kWh | $ | MMBtu | $ | Tgal | $ | gal | $ | lb | $ | $ | |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
Electricity Usage | Natural Gas | Water Disposal | Other Liquid (non-haz) | Solid Waste (non-haz) | Administrative Changes | Electricity Usage | Natural Gas | Water Disposal | Other Liquid (non-haz) | Solid Waste (non-haz) | Administrative Changes |