Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
IAC Center | San Francisco State University |
---|---|
Assessment Year | 1996 |
Principal Product | Breads and Baked Goods |
NAICS | n/a |
SIC | 2051 - Bread, Cake, And Related Products |
Sales | $1,000,000-$5,000,000 |
# of Employees | 46 |
Plant Area (Sq.Ft.) | 35,000 |
Annual Production | 2,700,000 Pounds |
Production Hrs. Annual | 4,160 |
Location (State) | CA |
Source | Yearly Cost | Usage | Unit | Unit Cost |
---|---|---|---|---|
Electricity Usage | $25,340 | 368,406 | kWh | $0.07 |
Electricity Demand | $18,326 | 1,476 | kW-months/year | $12.42 |
Natural Gas | $49,267 | 8,214 | MMBtu | $6.00 |
TOTAL ENERGY COSTS | $93,906 | |||
RECOMMENDED SAVINGS* | $5,003 | *Non-energy impacts included in savings. See recommendations below |
||
IMPLEMENTED SAVINGS* | $158 |
#|Description |
Savings Cost |
Status | Electricity Usage | Electricity Demand | Solid Waste (non-haz) | Electricity Usage | Electricity Demand | Solid Waste (non-haz) | |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
$ | kWh | $ | kW-months/year | $ | lb | ||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
01: 2.7142 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS |
Savings: $3,591 Cost: $10,680 |
$2,304 | 33,411 | $1,287 | 104 | - | - |
$2,304 33,411 kWh |
$1,287 104 kW-months/year |
- - lb |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
02: 2.4133 USE MOST EFFICIENT TYPE OF ELECTRIC MOTORS |
Savings: $273 Cost: $613 |
$187 | 2,638 | $86 | 7 | - | - |
$187 2,638 kWh |
$86 7 kW-months/year |
- - lb |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
03: 2.4221 INSTALL COMPRESSOR AIR INTAKES IN COOLEST LOCATIONS |
Savings: $158 Cost: $410 |
$104 | 1,465 | $54 | 4 | - | - |
$104 1,465 kWh |
$54 4 kW-months/year |
- - lb |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
04: 2.4111 UTILIZE ENERGY-EFFICIENT BELTS AND OTHER IMPROVED MECHANISMS |
Savings: $460 Cost: $839 |
$315 | 4,396 | $145 | 11 | - | - |
$315 4,396 kWh |
$145 11 kW-months/year |
- - lb |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
05: 2.4314 USE SYNTHETIC LUBRICANT |
Savings: $69 Cost: $155 |
$45 | 586 | $24 | 2 | - | - |
$45 586 kWh |
$24 2 kW-months/year |
- - lb |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
06: 3.5315 LEASE / PURCHASE BALER; SELL CARDBOARD TO RECYCLER |
Savings: $452 Cost: $500 |
- | - | - | - | $452 | - |
- - kWh |
- - kW-months/year |
$452 - lb |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
TOTAL RECOMMENDED |
Savings: $5,003 Cost: $13,197 |
$2,955 | 42,496 | $1,596 | 128 | $452 | - | $2,955 42,496 kWh |
$1,596 128 kW-months/year |
$452 - lb |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
TOTAL IMPLEMENTED |
Savings: $158 Cost: $410 |
$104 | 1,465 | $54 | 4 | - | - | $104 1,465 kWh |
$54 4 kW-months/year |
- - lb |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
Savings Cost |
$ | kWh | $ | kW-months/year | $ | lb | |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
Electricity Usage | Electricity Demand | Solid Waste (non-haz) | Electricity Usage | Electricity Demand | Solid Waste (non-haz) |