Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
IAC Center | San Francisco State University |
---|---|
Assessment Year | 1996 |
Principal Product | Plastic Injection Parts |
NAICS | n/a |
SIC | 3089 - Plastics Products, Nec |
Sales | $1,000,000-$5,000,000 |
# of Employees | 40 |
Plant Area (Sq.Ft.) | 13,000 |
Annual Production | 4,000,000 Pieces |
Production Hrs. Annual | 2,800 |
Location (State) | CA |
Source | Yearly Cost | Usage | Unit | Unit Cost |
---|---|---|---|---|
Electricity Usage | $43,326 | 483,587 | kWh | $0.09 |
Electricity Demand | $8,985 | 2,160 | kW-months/year | $4.16 |
Natural Gas | $851 | 100 | MMBtu | $8.51 |
TOTAL ENERGY COSTS | $57,485 | |||
RECOMMENDED SAVINGS* | $19,757 | *Non-energy impacts included in savings. See recommendations below |
||
IMPLEMENTED SAVINGS* | $3,329 |
#|Description |
Savings Cost |
Status | Electricity Usage | Electricity Demand | Natural Gas | Solid Waste (non-haz) | By-product Production | Electricity Usage | Electricity Demand | Natural Gas | Solid Waste (non-haz) | By-product Production | |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
$ | kWh | $ | kW-months/year | $ | MMBtu | $ | lb | $ | $ | ||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
01: 2.4133 USE MOST EFFICIENT TYPE OF ELECTRIC MOTORS |
Savings: $183 Cost: $653 |
$146 | 1,758 | $37 | 9 | - | - | - | - | - | - |
$146 1,758 kWh |
$37 9 kW-months/year |
- - MMBtu |
- - lb |
- - $ |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
02: 2.7142 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS |
Savings: $3,146 Cost: $12,480 |
$2,556 | 28,429 | $590 | 142 | - | - | - | - | - | - |
$2,556 28,429 kWh |
$590 142 kW-months/year |
- - MMBtu |
- - lb |
- - $ |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
03: 2.1311 REPLACE ELECTRICALLY-OPERATED EQUIPMENT WITH FOSSIL FUEL EQUIPMENT |
Savings: $1,762 Cost: $1,975 |
$2,016 | 22,567 | $562 | 135 | $(-816) | (-109) | - | - | - | - |
$2,016 22,567 kWh |
$562 135 kW-months/year |
$(-816) (-109) MMBtu |
- - lb |
- - $ |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
04: 2.2511 INSULATE BARE EQUIPMENT |
Savings: $4,296 Cost: $8,880 |
$4,296 | 48,066 | - | - | - | - | - | - | - | - |
$4,296 48,066 kWh |
- - kW-months/year |
- - MMBtu |
- - lb |
- - $ |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
05: 3.5212 REGRIND, REUSE, OR SELL SCRAP PLASTIC PARTS |
Savings: $10,370 Cost: $500 |
- | - | - | - | - | - | $3,265 | 22,400 | $7,105 | - |
- - kWh |
- - kW-months/year |
- - MMBtu |
$3,265 22,400 lb |
$7,105 - $ |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
TOTAL RECOMMENDED |
Savings: $19,757 Cost: $24,488 |
$9,014 | 100,820 | $1,189 | 286 | $(-816) | (-109) | $3,265 | 22,400 | $7,105 | - | $9,014 100,820 kWh |
$1,189 286 kW-months/year |
$(-816) (-109) MMBtu |
$3,265 22,400 lb |
$7,105 - $ |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
TOTAL IMPLEMENTED |
Savings: $3,329 Cost: $13,133 |
$2,702 | 30,187 | $627 | 151 | - | - | - | - | - | - | $2,702 30,187 kWh |
$627 151 kW-months/year |
- - MMBtu |
- - lb |
- - $ |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
Savings Cost |
$ | kWh | $ | kW-months/year | $ | MMBtu | $ | lb | $ | $ | |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
Electricity Usage | Electricity Demand | Natural Gas | Solid Waste (non-haz) | By-product Production | Electricity Usage | Electricity Demand | Natural Gas | Solid Waste (non-haz) | By-product Production |