Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
IAC Center San Francisco State University
Assessment Year 1996
Principal Product Garment Dyeing
NAICS n/a
SIC 2231 - Broadwoven Fabric Mills, Wool
Sales $1,000,000-$5,000,000
# of Employees 45
Plant Area (Sq.Ft.) 30,000
Annual Production 2,300,000 Pounds
Production Hrs. Annual 6,448
Location (State) CA
Source Yearly Cost Usage Unit Unit Cost
Electricity Usage $39,427 432,884 kWh $0.09
Electricity Demand $3,952 949 kW-months/year $4.16
Natural Gas $146,881 60,591 MMBtu $2.42
TOTAL ENERGY COSTS $243,943
RECOMMENDED SAVINGS* $94,847 *Non-energy impacts
included in savings.
See recommendations below
IMPLEMENTED SAVINGS* -
#|Description Savings
Cost
Status Electricity Usage Electricity Demand Natural Gas Water Disposal Water Consumption Electricity Usage Electricity Demand Natural Gas Water Disposal Water Consumption
$ kWh $ kW-months/year $ MMBtu $ Tgal $ Tgal
01: 2.4133 USE MOST EFFICIENT TYPE OF ELECTRIC MOTORS Savings:
$275
Cost:
$253
$253 2,638 $22 5 - - - - - - $253
2,638
kWh
$22
5
kW-months/year
-
-
MMBtu
-
-
Tgal
-
-
Tgal
02: 2.7142 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS Savings:
$1,710
Cost:
$5,640
$1,519 16,706 $191 46 - - - - - - $1,519
16,706
kWh
$191
46
kW-months/year
-
-
MMBtu
-
-
Tgal
-
-
Tgal
03: 2.4111 UTILIZE ENERGY-EFFICIENT BELTS AND OTHER IMPROVED MECHANISMS Savings:
$303
Cost:
$720
$279 2,931 $24 6 - - - - - - $279
2,931
kWh
$24
6
kW-months/year
-
-
MMBtu
-
-
Tgal
-
-
Tgal
04: 2.1243 USE HEAT FROM BOILER BLOWDOWN TO PREHEAT BOILER FEED WATER Savings:
$4,132
Cost:
$8,500
- - - - $4,132 3,141 - - - - -
-
kWh
-
-
kW-months/year
$4,132
3,141
MMBtu
-
-
Tgal
-
-
Tgal
05: 2.2136 INSTALL / REPAIR INSULATION ON STEAM LINES Savings:
$970
Cost:
$1,183
- - - - $970 400 - - - - -
-
kWh
-
-
kW-months/year
$970
400
MMBtu
-
-
Tgal
-
-
Tgal
06: 3.4113 TREAT AND REUSE RINSE WATERS Savings:
$87,457
Cost:
$173,000
- - - - - - $47,526 21,560,000 $39,931 - -
-
kWh
-
-
kW-months/year
-
-
MMBtu
$47,526
21,560,000
Tgal
$39,931
-
Tgal
TOTAL RECOMMENDED Savings:
$94,847
Cost:
$189,296
$2,051 22,275 $237 57 $5,102 3,541 $47,526 21,560,000 $39,931 - $2,051
22,275
kWh
$237
57
kW-months/year
$5,102
3,541
MMBtu
$47,526
21,560,000
Tgal
$39,931
-
Tgal
TOTAL IMPLEMENTED Savings:
-
Cost:
-
- - - - - - - - - - -
-
kWh
-
-
kW-months/year
-
-
MMBtu
-
-
Tgal
-
-
Tgal
Savings
Cost
$ kWh $ kW-months/year $ MMBtu $ Tgal $ Tgal
Electricity Usage Electricity Demand Natural Gas Water Disposal Water Consumption Electricity Usage Electricity Demand Natural Gas Water Disposal Water Consumption