Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
IAC Center | San Francisco State University |
---|---|
Assessment Year | 1997 |
Principal Product | Cooked & Dried Meat Products |
NAICS | n/a |
SIC | 2013 - Sausages And Other Prepared Meats |
Sales | $10,000,000-$50,000,000 |
# of Employees | 120 |
Plant Area (Sq.Ft.) | 85,000 |
Annual Production | 6,000,000 Pounds |
Production Hrs. Annual | 5,005 |
Location (State) | CA |
Source | Yearly Cost | Usage | Unit | Unit Cost |
---|---|---|---|---|
Electricity Usage | $239,738 | 4,111,665 | kWh | $0.06 |
Electricity Demand | $103,727 | 7,947 | kW-months/year | $13.05 |
Natural Gas | $96,913 | 18,725 | MMBtu | $5.18 |
TOTAL ENERGY COSTS | $524,179 | |||
RECOMMENDED SAVINGS* | $147,532 | *Non-energy impacts included in savings. See recommendations below |
||
IMPLEMENTED SAVINGS* | - |
#|Description |
Savings Cost |
Status | Electricity Usage | Electricity Demand | Electricity Fees | Water Disposal | Solid Waste (non-haz) | Personnel Changes | Electricity Usage | Electricity Demand | Electricity Fees | Water Disposal | Solid Waste (non-haz) | Personnel Changes | |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
$ | kWh | $ | kW-months/year | $ | $ | $ | Tgal | $ | lb | $ | $ | ||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
01: 2.7142 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS |
Savings: $19,567 Cost: $25,020 |
$14,336 | 245,897 | $5,231 | 401 | - | - | - | - | - | - | - | - |
$14,336 245,897 kWh |
$5,231 401 kW-months/year |
- - $ |
- - Tgal |
- - lb |
- - $ |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
02: 2.7133 USE SEPARATE SWITCHES ON PERIMETER LIGHTING WHICH MAY BE TURNED OFF WHEN NATURAL LIGHT IS AVAILABLE |
Savings: $8,269 Cost: $19,750 |
$6,921 | 118,699 | $1,348 | 103 | - | - | - | - | - | - | - | - |
$6,921 118,699 kWh |
$1,348 103 kW-months/year |
- - $ |
- - Tgal |
- - lb |
- - $ |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
03: 2.4133 USE MOST EFFICIENT TYPE OF ELECTRIC MOTORS |
Savings: $1,606 Cost: $1,680 |
$1,184 | 20,223 | $422 | 32 | - | - | - | - | - | - | - | - |
$1,184 20,223 kWh |
$422 32 kW-months/year |
- - $ |
- - Tgal |
- - lb |
- - $ |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
04: 2.3212 OPTIMIZE PLANT POWER FACTOR |
Savings: $1,784 Cost: $3,010 |
- | - | - | - | $1,784 | - | - | - | - | - | - | - |
- - kWh |
- - kW-months/year |
$1,784 - $ |
- - Tgal |
- - lb |
- - $ |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
05: 2.4236 ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES |
Savings: $1,656 Cost: $204 |
$1,237 | 21,102 | $419 | 32 | - | - | - | - | - | - | - | - |
$1,237 21,102 kWh |
$419 32 kW-months/year |
- - $ |
- - Tgal |
- - lb |
- - $ |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
06: 2.4231 REDUCE THE PRESSURE OF COMPRESSED AIR TO THE MINIMUM REQUIRED |
Savings: $790 Cost: - |
$518 | 8,792 | $272 | 21 | - | - | - | - | - | - | - | - |
$518 8,792 kWh |
$272 21 kW-months/year |
- - $ |
- - Tgal |
- - lb |
- - $ |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
07: 2.4239 ELIMINATE OR REDUCE COMPRESSED AIR USAGE |
Savings: $2,226 Cost: $175 |
$1,205 | 20,809 | $1,021 | 78 | - | - | - | - | - | - | - | - |
$1,205 20,809 kWh |
$1,021 78 kW-months/year |
- - $ |
- - Tgal |
- - lb |
- - $ |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
08: 3.4111 USE CLOSED CYCLE PROCESS TO MINIMIZE WASTE WATER PRODUCTION |
Savings: $7,233 Cost: $2,490 |
$(-1,489) | (-25,498) | - | - | - | - | $8,722 | 2,876,142 | - | - | - | - |
$(-1,489) (-25,498) kWh |
- - kW-months/year |
- - $ |
$8,722 2,876,142 Tgal |
- - lb |
- - $ |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
09: 3.4156 USE FLOW CONTROL VALVES ON EQUIPMENT TO OPTIMIZE WATER USE |
Savings: $4,893 Cost: - |
- | - | - | - | - | - | $4,893 | 1,201,615 | - | - | - | - |
- - kWh |
- - kW-months/year |
- - $ |
$4,893 1,201,615 Tgal |
- - lb |
- - $ |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
10: 3.5315 LEASE / PURCHASE BALER; SELL CARDBOARD TO RECYCLER |
Savings: $24,394 Cost: $250 |
- | - | - | - | - | - | - | - | $24,394 | - | - | - |
- - kWh |
- - kW-months/year |
- - $ |
- - Tgal |
$24,394 - lb |
- - $ |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
11: 4.441 INSTALL AUTOMATIC PACKING EQUIPMENT |
Savings: $21,040 Cost: $11,500 |
- | - | - | - | - | - | - | - | - | - | $21,040 | - |
- - kWh |
- - kW-months/year |
- - $ |
- - Tgal |
- - lb |
$21,040 - $ |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
12: 4.422 UTILIZE OUTSIDE CONTRACTING |
Savings: $54,074 Cost: $250 |
- | - | - | - | - | - | - | - | - | - | $54,074 | - |
- - kWh |
- - kW-months/year |
- - $ |
- - Tgal |
- - lb |
$54,074 - $ |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
TOTAL RECOMMENDED |
Savings: $147,532 Cost: $64,329 |
$23,912 | 410,024 | $8,713 | 667 | $1,784 | - | $13,615 | 4,077,757 | $24,394 | - | $75,114 | - | $23,912 410,024 kWh |
$8,713 667 kW-months/year |
$1,784 - $ |
$13,615 4,077,757 Tgal |
$24,394 - lb |
$75,114 - $ |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
TOTAL IMPLEMENTED |
Savings: - Cost: - |
- | - | - | - | - | - | - | - | - | - | - | - | - - kWh |
- - kW-months/year |
- - $ |
- - Tgal |
- - lb |
- - $ |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
Savings Cost |
$ | kWh | $ | kW-months/year | $ | $ | $ | Tgal | $ | lb | $ | $ | |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
Electricity Usage | Electricity Demand | Electricity Fees | Water Disposal | Solid Waste (non-haz) | Personnel Changes | Electricity Usage | Electricity Demand | Electricity Fees | Water Disposal | Solid Waste (non-haz) | Personnel Changes |