Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
IAC Center San Francisco State University
Assessment Year 1997
Principal Product Corrugated Containers
NAICS n/a
SIC 2653 - Corrugated And Solid Fiber Boxes
Sales $10,000,000-$50,000,000
# of Employees 65
Plant Area (Sq.Ft.) 114,000
Annual Production 120,000 Thousand Feet
Production Hrs. Annual 4,160
Location (State) CA
Source Yearly Cost Usage Unit Unit Cost
Electricity Usage $63,393 781,067 kWh $0.08
Electricity Demand $12,412 2,997 kW-months/year $4.14
Natural Gas $1,682 271 MMBtu $6.21
TOTAL ENERGY COSTS $(-138,945)
RECOMMENDED SAVINGS* $6,992 *Non-energy impacts
included in savings.
See recommendations below
IMPLEMENTED SAVINGS* $2,956
#|Description Savings
Cost
Status Electricity Usage Electricity Demand Solid Waste (non-haz) Electricity Usage Electricity Demand Solid Waste (non-haz)
$ kWh $ kW-months/year $ lb
01: 2.4133 USE MOST EFFICIENT TYPE OF ELECTRIC MOTORS Savings:
$262
Cost:
$623
$228 2,931 $34 8 - - $228
2,931
kWh
$34
8
kW-months/year
-
-
lb
02: 2.7144 INSTALL SPECTRAL REFLECTORS / DELAMP Savings:
$756
Cost:
$1,650
$625 7,620 $131 32 - - $625
7,620
kWh
$131
32
kW-months/year
-
-
lb
03: 2.7133 USE SEPARATE SWITCHES ON PERIMETER LIGHTING WHICH MAY BE TURNED OFF WHEN NATURAL LIGHT IS AVAILABLE Savings:
$2,539
Cost:
$4,000
$2,213 27,257 $326 79 - - $2,213
27,257
kWh
$326
79
kW-months/year
-
-
lb
04: 2.4111 UTILIZE ENERGY-EFFICIENT BELTS AND OTHER IMPROVED MECHANISMS Savings:
$242
Cost:
$168
$211 2,638 $31 7 - - $211
2,638
kWh
$31
7
kW-months/year
-
-
lb
05: 2.4239 ELIMINATE OR REDUCE COMPRESSED AIR USAGE Savings:
$302
Cost:
$124
$302 3,810 - - - - $302
3,810
kWh
-
-
kW-months/year
-
-
lb
06: 2.4239 ELIMINATE OR REDUCE COMPRESSED AIR USAGE Savings:
$1,497
Cost:
$3,347
$1,305 16,120 $192 46 - - $1,305
16,120
kWh
$192
46
kW-months/year
-
-
lb
07: 3.5313 INCREASE AMOUNT OF WASTE RECOVERED FOR RESALE Savings:
$1,394
Cost:
-
- - - - $1,394 5,200 -
-
kWh
-
-
kW-months/year
$1,394
5,200
lb
TOTAL RECOMMENDED Savings:
$6,992
Cost:
$9,912
$4,884 60,376 $714 172 $1,394 5,200 $4,884
60,376
kWh
$714
172
kW-months/year
$1,394
5,200
lb
TOTAL IMPLEMENTED Savings:
$2,956
Cost:
$2,565
$1,366 16,999 $196 47 $1,394 5,200 $1,366
16,999
kWh
$196
47
kW-months/year
$1,394
5,200
lb
Savings
Cost
$ kWh $ kW-months/year $ lb
Electricity Usage Electricity Demand Solid Waste (non-haz) Electricity Usage Electricity Demand Solid Waste (non-haz)