Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
IAC Center San Francisco State University
Assessment Year 1998
Principal Product Wood & Upholstery Furniture
NAICS n/a
SIC 2531 - Public Building & Related Furniture
Sales $10,000,000-$50,000,000
# of Employees 118
Plant Area (Sq.Ft.) 60,000
Annual Production 220,000 Pieces
Production Hrs. Annual 4,680
Location (State) CA
Source Yearly Cost Usage Unit Unit Cost
Electricity Usage $69,086 1,083,236 kWh $0.06
Electricity Demand $21,035 3,965 kW-months/year $5.31
Natural Gas $8,448 1,268 MMBtu $6.66
TOTAL ENERGY COSTS $133,355
RECOMMENDED SAVINGS* $197,535 *Non-energy impacts
included in savings.
See recommendations below
IMPLEMENTED SAVINGS* $170,132
#|Description Savings
Cost
Status Electricity Usage Electricity Demand Solid Waste (non-haz) Increase in Production Electricity Usage Electricity Demand Solid Waste (non-haz) Increase in Production
$ kWh $ kW-months/year $ lb $ %
01: 2.4236 ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES Savings:
$3,673
Cost:
-
$3,394 53,048 $279 53 - - - - $3,394
53,048
kWh
$279
53
kW-months/year
-
-
lb
-
-
%
02: 2.7131 ADD AREA LIGHTING SWITCHES Savings:
$860
Cost:
$90
$860 13,482 - - - - - - $860
13,482
kWh
-
-
kW-months/year
-
-
lb
-
-
%
03: 2.7142 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS Savings:
$1,521
Cost:
$1,200
$1,028 16,120 $493 93 - - - - $1,028
16,120
kWh
$493
93
kW-months/year
-
-
lb
-
-
%
04: 2.7142 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS Savings:
$267
Cost:
$233
$203 3,224 $64 12 - - - - $203
3,224
kWh
$64
12
kW-months/year
-
-
lb
-
-
%
05: 2.7142 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS Savings:
$3,097
Cost:
$5,250
$2,094 32,825 $1,003 189 - - - - $2,094
32,825
kWh
$1,003
189
kW-months/year
-
-
lb
-
-
%
06: 2.4133 USE MOST EFFICIENT TYPE OF ELECTRIC MOTORS Savings:
$469
Cost:
$905
$374 5,862 $95 18 - - - - $374
5,862
kWh
$95
18
kW-months/year
-
-
lb
-
-
%
07: 2.7142 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS Savings:
$6,456
Cost:
$14,990
$4,891 76,788 $1,565 295 - - - - $4,891
76,788
kWh
$1,565
295
kW-months/year
-
-
lb
-
-
%
08: 2.4146 USE ADJUSTABLE FREQUENCY DRIVE OR MULTIPLE SPEED MOTORS ON EXISTING SYSTEM Savings:
$6,827
Cost:
$24,062
$6,827 106,975 - - - - - - $6,827
106,975
kWh
-
-
kW-months/year
-
-
lb
-
-
%
09: 3.5313 INCREASE AMOUNT OF WASTE RECOVERED FOR RESALE Savings:
$22,785
Cost:
$100
- - - - $22,785 - - - -
-
kWh
-
-
kW-months/year
$22,785
-
lb
-
-
%
10: 4.111 ADD EQUIPMENT/ OPERATORS TO REDUCE PRODUCTION BOTTLENECK Savings:
$151,580
Cost:
$152,960
- - - - - - $151,580 - -
-
kWh
-
-
kW-months/year
-
-
lb
$151,580
-
%
TOTAL RECOMMENDED Savings:
$197,535
Cost:
$199,790
$19,671 308,324 $3,499 660 $22,785 - $151,580 - $19,671
308,324
kWh
$3,499
660
kW-months/year
$22,785
-
lb
$151,580
-
%
TOTAL IMPLEMENTED Savings:
$170,132
Cost:
$193,240
$16,549 259,379 $2,003 378 - - $151,580 - $16,549
259,379
kWh
$2,003
378
kW-months/year
-
-
lb
$151,580
-
%
Savings
Cost
$ kWh $ kW-months/year $ lb $ %
Electricity Usage Electricity Demand Solid Waste (non-haz) Increase in Production Electricity Usage Electricity Demand Solid Waste (non-haz) Increase in Production