Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
IAC Center | San Francisco State University |
---|---|
Assessment Year | 1998 |
Principal Product | Custom Printed Material |
NAICS | n/a |
SIC | 2759 - Commercial Printing, Nec |
Sales | $10,000,000-$50,000,000 |
# of Employees | 300 |
Plant Area (Sq.Ft.) | 130,000 |
Annual Production | 249,600,000 Pieces |
Production Hrs. Annual | 7,488 |
Location (State) | CA |
Source | Yearly Cost | Usage | Unit | Unit Cost |
---|---|---|---|---|
Electricity Usage | $167,659 | 2,387,163 | kWh | $0.07 |
Electricity Demand | $68,463 | 6,819 | kW-months/year | $10.04 |
Natural Gas | $31,226 | 5,478 | MMBtu | $5.70 |
TOTAL ENERGY COSTS | $281,613 | |||
RECOMMENDED SAVINGS* | $97,604 | *Non-energy impacts included in savings. See recommendations below |
||
IMPLEMENTED SAVINGS* | - |
#|Description |
Savings Cost |
Status | Electricity Usage | Electricity Demand | Natural Gas | Other Liquid (haz) | Solid Waste (non-haz) | Primary Raw Material | Electricity Usage | Electricity Demand | Natural Gas | Other Liquid (haz) | Solid Waste (non-haz) | Primary Raw Material | |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
$ | kWh | $ | kW-months/year | $ | MMBtu | $ | gal | $ | lb | $ | $ | ||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
01: 2.8114 CHANGE RATE SCHEDULES OR OTHER CHANGES IN UTILITY SERVICE |
Savings: $10,516 Cost: $240 |
- | - | - | - | $10,516 | - | - | - | - | - | - | - |
- - kWh |
- - kW-months/year |
$10,516 - MMBtu |
- - gal |
- - lb |
- - $ |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
02: 2.7142 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS |
Savings: $5,893 Cost: $2,924 |
$4,309 | 61,254 | $1,584 | 158 | - | - | - | - | - | - | - | - |
$4,309 61,254 kWh |
$1,584 158 kW-months/year |
- - MMBtu |
- - gal |
- - lb |
- - $ |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
03: 2.7135 INSTALL OCCUPANCY SENSORS |
Savings: $2,197 Cost: $1,728 |
$1,507 | 21,395 | $690 | 69 | - | - | - | - | - | - | - | - |
$1,507 21,395 kWh |
$690 69 kW-months/year |
- - MMBtu |
- - gal |
- - lb |
- - $ |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
04: 2.4133 USE MOST EFFICIENT TYPE OF ELECTRIC MOTORS |
Savings: $1,117 Cost: $858 |
$902 | 12,896 | $215 | 22 | - | - | - | - | - | - | - | - |
$902 12,896 kWh |
$215 22 kW-months/year |
- - MMBtu |
- - gal |
- - lb |
- - $ |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
05: 2.7142 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS |
Savings: $25,307 Cost: $36,660 |
$20,091 | 286,049 | $5,216 | 519 | - | - | - | - | - | - | - | - |
$20,091 286,049 kWh |
$5,216 519 kW-months/year |
- - MMBtu |
- - gal |
- - lb |
- - $ |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
06: 2.7142 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS |
Savings: $8,230 Cost: $13,240 |
$6,694 | 95,252 | $1,536 | 153 | - | - | - | - | - | - | - | - |
$6,694 95,252 kWh |
$1,536 153 kW-months/year |
- - MMBtu |
- - gal |
- - lb |
- - $ |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
07: 2.4111 UTILIZE ENERGY-EFFICIENT BELTS AND OTHER IMPROVED MECHANISMS |
Savings: $259 Cost: $702 |
$155 | 2,345 | $104 | 11 | - | - | - | - | - | - | - | - |
$155 2,345 kWh |
$104 11 kW-months/year |
- - MMBtu |
- - gal |
- - lb |
- - $ |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
08: 3.5313 INCREASE AMOUNT OF WASTE RECOVERED FOR RESALE |
Savings: $5,866 Cost: - |
- | - | - | - | - | - | - | - | $5,866 | - | - | - |
- - kWh |
- - kW-months/year |
- - MMBtu |
- - gal |
$5,866 - lb |
- - $ |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
09: 3.5316 CONTRACT A WOOD PALLET RECYCLING COMPANY |
Savings: $3,642 Cost: $200 |
- | - | - | - | - | - | - | - | $3,642 | - | - | - |
- - kWh |
- - kW-months/year |
- - MMBtu |
- - gal |
$3,642 - lb |
- - $ |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
10: 3.6193 INSTALL EQUIPMENT (eg COMPACTOR) TO REDUCE DISPOSAL COSTS |
Savings: $7,861 Cost: $8,700 |
- | - | - | - | - | - | - | - | $7,861 | 46,720 | - | - |
- - kWh |
- - kW-months/year |
- - MMBtu |
- - gal |
$7,861 46,720 lb |
- - $ |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
11: 3.5313 INCREASE AMOUNT OF WASTE RECOVERED FOR RESALE |
Savings: $12,856 Cost: $10,280 |
- | - | - | - | - | - | - | - | $12,856 | - | - | - |
- - kWh |
- - kW-months/year |
- - MMBtu |
- - gal |
$12,856 - lb |
- - $ |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
12: 3.8143 RECYCLE CLEANING SOLVENT AND REUSE |
Savings: $13,860 Cost: $40,000 |
- | - | - | - | - | - | $6,160 | 1,540 | - | - | $7,700 | - |
- - kWh |
- - kW-months/year |
- - MMBtu |
$6,160 1,540 gal |
- - lb |
$7,700 - $ |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
TOTAL RECOMMENDED |
Savings: $97,604 Cost: $115,532 |
$33,658 | 479,191 | $9,345 | 932 | $10,516 | - | $6,160 | 1,540 | $30,225 | 46,720 | $7,700 | - | $33,658 479,191 kWh |
$9,345 932 kW-months/year |
$10,516 - MMBtu |
$6,160 1,540 gal |
$30,225 46,720 lb |
$7,700 - $ |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
TOTAL IMPLEMENTED |
Savings: - Cost: - |
- | - | - | - | - | - | - | - | - | - | - | - | - - kWh |
- - kW-months/year |
- - MMBtu |
- - gal |
- - lb |
- - $ |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
Savings Cost |
$ | kWh | $ | kW-months/year | $ | MMBtu | $ | gal | $ | lb | $ | $ | |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
Electricity Usage | Electricity Demand | Natural Gas | Other Liquid (haz) | Solid Waste (non-haz) | Primary Raw Material | Electricity Usage | Electricity Demand | Natural Gas | Other Liquid (haz) | Solid Waste (non-haz) | Primary Raw Material |