Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
IAC Center | San Francisco State University |
---|---|
Assessment Year | 1998 |
Principal Product | Cans/Ends |
NAICS | n/a |
SIC | 3829 - Measuring & Controlling Devices, Nec |
Sales | $50,000,000-$100,000,000 |
# of Employees | 300 |
Plant Area (Sq.Ft.) | 394,113 |
Annual Production | 300,000,000 Pieces |
Production Hrs. Annual | 7,488 |
Location (State) | CA |
Source | Yearly Cost | Usage | Unit | Unit Cost |
---|---|---|---|---|
Electricity Usage | $433,461 | 7,937,866 | kWh | $0.05 |
Electricity Demand | $193,897 | 15,221 | kW-months/year | $12.74 |
Natural Gas | $421,834 | 106,301 | MMBtu | $3.97 |
TOTAL ENERGY COSTS | $527,910 | |||
RECOMMENDED SAVINGS* | $574,642 | *Non-energy impacts included in savings. See recommendations below |
||
IMPLEMENTED SAVINGS* | $18,726 |
#|Description |
Savings Cost |
Status | Electricity Usage | Electricity Demand | Natural Gas | Solid Waste (non-haz) | Personnel Changes | Electricity Usage | Electricity Demand | Natural Gas | Solid Waste (non-haz) | Personnel Changes | |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
$ | kWh | $ | kW-months/year | $ | MMBtu | $ | lb | $ | $ | ||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
01: 2.4236 ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES |
Savings: $1,737 Cost: - |
$1,737 | 6,155 | - | - | - | - | - | - | - | - |
$1,737 6,155 kWh |
- - kW-months/year |
- - MMBtu |
- - lb |
- - $ |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
02: 2.2511 INSULATE BARE EQUIPMENT |
Savings: $555 Cost: $349 |
$555 | 10,258 | - | - | - | - | - | - | - | - |
$555 10,258 kWh |
- - kW-months/year |
- - MMBtu |
- - lb |
- - $ |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
03: 2.4133 USE MOST EFFICIENT TYPE OF ELECTRIC MOTORS |
Savings: $3,271 Cost: $2,284 |
$2,381 | 42,497 | $890 | 70 | - | - | - | - | - | - |
$2,381 42,497 kWh |
$890 70 kW-months/year |
- - MMBtu |
- - lb |
- - $ |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
04: 2.7134 USE PHOTOCELL CONTROLS |
Savings: $1,199 Cost: $1,000 |
$575 | 10,551 | $624 | 49 | - | - | - | - | - | - |
$575 10,551 kWh |
$624 49 kW-months/year |
- - MMBtu |
- - lb |
- - $ |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
05: 2.7135 INSTALL OCCUPANCY SENSORS |
Savings: $1,711 Cost: $2,464 |
$1,145 | 21,102 | $566 | 44 | - | - | - | - | - | - |
$1,145 21,102 kWh |
$566 44 kW-months/year |
- - MMBtu |
- - lb |
- - $ |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
06: 2.4239 ELIMINATE OR REDUCE COMPRESSED AIR USAGE |
Savings: $1,122 Cost: $1,600 |
$920 | 16,999 | $202 | 16 | - | - | - | - | - | - |
$920 16,999 kWh |
$202 16 kW-months/year |
- - MMBtu |
- - lb |
- - $ |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
07: 2.4111 UTILIZE ENERGY-EFFICIENT BELTS AND OTHER IMPROVED MECHANISMS |
Savings: $4,821 Cost: $7,370 |
$3,521 | 64,478 | $1,300 | 104 | - | - | - | - | - | - |
$3,521 64,478 kWh |
$1,300 104 kW-months/year |
- - MMBtu |
- - lb |
- - $ |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
08: 2.4239 ELIMINATE OR REDUCE COMPRESSED AIR USAGE |
Savings: $2,993 Cost: $4,500 |
$2,181 | 39,859 | $812 | 63 | - | - | - | - | - | - |
$2,181 39,859 kWh |
$812 63 kW-months/year |
- - MMBtu |
- - lb |
- - $ |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
09: 2.7142 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS |
Savings: $10,253 Cost: $17,610 |
$7,198 | 131,887 | $3,055 | 240 | - | - | - | - | - | - |
$7,198 131,887 kWh |
$3,055 240 kW-months/year |
- - MMBtu |
- - lb |
- - $ |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
10: 2.1311 REPLACE ELECTRICALLY-OPERATED EQUIPMENT WITH FOSSIL FUEL EQUIPMENT |
Savings: $76,331 Cost: $262,000 |
$116,032 | 2,125,147 | $43,388 | 3,406 | $(-83,089) | (-20,929) | - | - | - | - |
$116,032 2,125,147 kWh |
$43,388 3,406 kW-months/year |
$(-83,089) (-20,929) MMBtu |
- - lb |
- - $ |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
11: 3.5248 SEPARATE AND RECYCLE SCRAP METAL TO FOUNDRY OR FOR SALE |
Savings: $3,974 Cost: - |
- | - | - | - | - | - | $3,974 | - | - | - |
- - kWh |
- - kW-months/year |
- - MMBtu |
$3,974 - lb |
- - $ |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
12: 3.5313 INCREASE AMOUNT OF WASTE RECOVERED FOR RESALE |
Savings: $3,575 Cost: - |
- | - | - | - | - | - | $3,575 | - | - | - |
- - kWh |
- - kW-months/year |
- - MMBtu |
$3,575 - lb |
- - $ |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
13: 3.1162 USE LESS WASTEFUL PACKAGING |
Savings: $48,140 Cost: $30,000 |
- | - | - | - | - | - | $48,140 | 106,000 | - | - |
- - kWh |
- - kW-months/year |
- - MMBtu |
$48,140 106,000 lb |
- - $ |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
14: 4.441 INSTALL AUTOMATIC PACKING EQUIPMENT |
Savings: $207,480 Cost: $100,700 |
- | - | - | - | - | - | - | - | $207,480 | - |
- - kWh |
- - kW-months/year |
- - MMBtu |
- - lb |
$207,480 - $ |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
15: 4.445 INSTALL EQUIPMENT TO MOVE PRODUCT |
Savings: $207,480 Cost: $100,000 |
- | - | - | - | - | - | - | - | $207,480 | - |
- - kWh |
- - kW-months/year |
- - MMBtu |
- - lb |
$207,480 - $ |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
TOTAL RECOMMENDED |
Savings: $574,642 Cost: $529,877 |
$136,245 | 2,468,933 | $50,837 | 3,992 | $(-83,089) | (-20,929) | $55,689 | 106,000 | $414,960 | - | $136,245 2,468,933 kWh |
$50,837 3,992 kW-months/year |
$(-83,089) (-20,929) MMBtu |
$55,689 106,000 lb |
$414,960 - $ |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
TOTAL IMPLEMENTED |
Savings: $18,726 Cost: $23,707 |
$13,591 | 222,450 | $5,135 | 403 | - | - | - | - | - | - | $13,591 222,450 kWh |
$5,135 403 kW-months/year |
- - MMBtu |
- - lb |
- - $ |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
Savings Cost |
$ | kWh | $ | kW-months/year | $ | MMBtu | $ | lb | $ | $ | |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||