Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
IAC Center San Francisco State University
Assessment Year 1998
Principal Product Futons
NAICS n/a
SIC 2515 - Mattresses And Bedsprings
Sales $10,000,000-$50,000,000
# of Employees 125
Plant Area (Sq.Ft.) 70,000
Annual Production 45,000 Pieces
Production Hrs. Annual 4,160
Location (State) CA
Source Yearly Cost Usage Unit Unit Cost
Electricity Usage $22,248 270,516 kWh $0.08
Electricity Demand $4,204 873 kW-months/year $4.82
Natural Gas $6,838 1,031 MMBtu $6.63
TOTAL ENERGY COSTS $48,055
RECOMMENDED SAVINGS* $13,081 *Non-energy impacts
included in savings.
See recommendations below
IMPLEMENTED SAVINGS* $5,450
#|Description Savings
Cost
Status Electricity Usage Electricity Demand Solid Waste (non-haz) Electricity Usage Electricity Demand Solid Waste (non-haz)
$ kWh $ kW-months/year $ lb
01: 2.4111 UTILIZE ENERGY-EFFICIENT BELTS AND OTHER IMPROVED MECHANISMS Savings:
$300
Cost:
$260
$257 2,931 $43 9 - - $257
2,931
kWh
$43
9
kW-months/year
-
-
lb
02: 2.4133 USE MOST EFFICIENT TYPE OF ELECTRIC MOTORS Savings:
$75
Cost:
$147
$64 879 $11 2 - - $64
879
kWh
$11
2
kW-months/year
-
-
lb
03: 2.7142 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS Savings:
$7,331
Cost:
$22,713
$6,229 75,615 $1,102 229 - - $6,229
75,615
kWh
$1,102
229
kW-months/year
-
-
lb
04: 3.5313 INCREASE AMOUNT OF WASTE RECOVERED FOR RESALE Savings:
$5,375
Cost:
-
- - - - $5,375 - -
-
kWh
-
-
kW-months/year
$5,375
-
lb
TOTAL RECOMMENDED Savings:
$13,081
Cost:
$23,120
$6,550 79,425 $1,156 240 $5,375 - $6,550
79,425
kWh
$1,156
240
kW-months/year
$5,375
-
lb
TOTAL IMPLEMENTED Savings:
$5,450
Cost:
$147
$64 879 $11 2 $5,375 - $64
879
kWh
$11
2
kW-months/year
$5,375
-
lb
Savings
Cost
$ kWh $ kW-months/year $ lb
Electricity Usage Electricity Demand Solid Waste (non-haz) Electricity Usage Electricity Demand Solid Waste (non-haz)