Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
IAC Center San Francisco State University
Assessment Year 1998
Principal Product Canned Fruits
NAICS n/a
SIC 2030 -
Sales $50,000,000-$100,000,000
# of Employees 1,500
Plant Area (Sq.Ft.) 500,000
Annual Production 500,000,000 Pounds
Production Hrs. Annual 1,584
Location (State) CA
Source Yearly Cost Usage Unit Unit Cost
Electricity Usage $376,035 10,390,973 kWh $0.04
Electricity Demand $165,873 21,526 kW-months/year $7.71
Natural Gas $463,141 214,036 MMBtu $2.16
TOTAL ENERGY COSTS $2,433,078
RECOMMENDED SAVINGS* $224,635 *Non-energy impacts
included in savings.
See recommendations below
IMPLEMENTED SAVINGS* -
#|Description Savings
Cost
Status Electricity Usage Electricity Demand Natural Gas Water Disposal Solid Waste (non-haz) Water Consumption Electricity Usage Electricity Demand Natural Gas Water Disposal Solid Waste (non-haz) Water Consumption
$ kWh $ kW-months/year $ MMBtu $ Tgal $ lb $ Tgal
01: 2.4231 REDUCE THE PRESSURE OF COMPRESSED AIR TO THE MINIMUM REQUIRED Savings:
$1,127
Cost:
$50
$992 27,550 $135 18 - - - - - - - - $992
27,550
kWh
$135
18
kW-months/year
-
-
MMBtu
-
-
Tgal
-
-
lb
-
-
Tgal
02: 2.2135 REPAIR AND ELIMINATE STEAM LEAKS Savings:
$1,107
Cost:
$1,250
- - - - $1,107 534 - - - - - - -
-
kWh
-
-
kW-months/year
$1,107
534
MMBtu
-
-
Tgal
-
-
lb
-
-
Tgal
03: 2.4133 USE MOST EFFICIENT TYPE OF ELECTRIC MOTORS Savings:
$2,947
Cost:
$7,021
$2,316 63,892 $631 82 - - - - - - - - $2,316
63,892
kWh
$631
82
kW-months/year
-
-
MMBtu
-
-
Tgal
-
-
lb
-
-
Tgal
04: 2.4111 UTILIZE ENERGY-EFFICIENT BELTS AND OTHER IMPROVED MECHANISMS Savings:
$2,191
Cost:
$5,404
$1,722 47,479 $469 61 - - - - - - - - $1,722
47,479
kWh
$469
61
kW-months/year
-
-
MMBtu
-
-
Tgal
-
-
lb
-
-
Tgal
05: 3.5313 INCREASE AMOUNT OF WASTE RECOVERED FOR RESALE Savings:
$42,254
Cost:
-
- - - - - - - - $42,254 - - - -
-
kWh
-
-
kW-months/year
-
-
MMBtu
-
-
Tgal
$42,254
-
lb
-
-
Tgal
06: 2.2121 INCREASE AMOUNT OF CONDENSATE RETURNED Savings:
$21,972
Cost:
$2,000
$6,949 942,849 - - - - $11,890 2,373,281 - - $3,133 - $6,949
942,849
kWh
-
-
kW-months/year
-
-
MMBtu
$11,890
2,373,281
Tgal
-
-
lb
$3,133
-
Tgal
07: 3.4111 USE CLOSED CYCLE PROCESS TO MINIMIZE WASTE WATER PRODUCTION Savings:
$7,108
Cost:
$399
$(-20) (-293) - - - - $4,762 950,400 - - $2,366 - $(-20)
(-293)
kWh
-
-
kW-months/year
-
-
MMBtu
$4,762
950,400
Tgal
-
-
lb
$2,366
-
Tgal
08: 3.4111 USE CLOSED CYCLE PROCESS TO MINIMIZE WASTE WATER PRODUCTION Savings:
$1,183
Cost:
$399
$(-20) (-293) - - - - $952 190,080 - - $251 - $(-20)
(-293)
kWh
-
-
kW-months/year
-
-
MMBtu
$952
190,080
Tgal
-
-
lb
$251
-
Tgal
09: 3.6193 INSTALL EQUIPMENT (eg COMPACTOR) TO REDUCE DISPOSAL COSTS Savings:
$144,746
Cost:
$120,400
- - - - - - - - $144,746 718,400 - - -
-
kWh
-
-
kW-months/year
-
-
MMBtu
-
-
Tgal
$144,746
718,400
lb
-
-
Tgal
TOTAL RECOMMENDED Savings:
$224,635
Cost:
$136,923
$11,939 1,081,184 $1,235 161 $1,107 534 $17,604 3,513,761 $187,000 718,400 $5,750 - $11,939
1,081,184
kWh
$1,235
161
kW-months/year
$1,107
534
MMBtu
$17,604
3,513,761
Tgal
$187,000
718,400
lb
$5,750
-
Tgal
TOTAL IMPLEMENTED Savings:
-
Cost:
-
- - - - - - - - - - - - -
-
kWh
-
-
kW-months/year
-
-
MMBtu
-
-
Tgal
-
-
lb
-
-
Tgal
Savings
Cost
$ kWh $ kW-months/year $ MMBtu $ Tgal $ lb $ Tgal
Electricity Usage Electricity Demand Natural Gas Water Disposal Solid Waste (non-haz) Water Consumption Electricity Usage Electricity Demand Natural Gas Water Disposal Solid Waste (non-haz) Water Consumption