Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
IAC Center | San Francisco State University |
---|---|
Assessment Year | 1999 |
Principal Product | Cans |
NAICS | n/a |
SIC | 3829 - Measuring & Controlling Devices, Nec |
Sales | $50,000,000-$100,000,000 |
# of Employees | 110 |
Plant Area (Sq.Ft.) | 62,000 |
Annual Production | 400,000,000 Pieces |
Production Hrs. Annual | 7,488 |
Location (State) | CA |
Source | Yearly Cost | Usage | Unit | Unit Cost |
---|---|---|---|---|
Electricity Usage | $165,091 | 4,311,254 | kWh | $0.04 |
Electricity Demand | $74,653 | 10,665 | kW-months/year | $7.00 |
Natural Gas | $30,614 | 6,115 | MMBtu | $5.01 |
TOTAL ENERGY COSTS | $251,589 | |||
RECOMMENDED SAVINGS* | $34,278 | *Non-energy impacts included in savings. See recommendations below |
||
IMPLEMENTED SAVINGS* | $26,417 |
#|Description |
Savings Cost |
Status | Electricity Usage | Electricity Demand | Electricity Fees | Solid Waste (non-haz) | Electricity Usage | Electricity Demand | Electricity Fees | Solid Waste (non-haz) | |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
$ | kWh | $ | kW-months/year | $ | $ | $ | lb | ||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
01: 2.4236 ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES |
Savings: $6,720 Cost: - |
$5,174 | 135,111 | $1,546 | 221 | - | - | - | - |
$5,174 135,111 kWh |
$1,546 221 kW-months/year |
- - $ |
- - lb |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
02: 2.4239 ELIMINATE OR REDUCE COMPRESSED AIR USAGE |
Savings: $4,207 Cost: $1,400 |
$3,241 | 84,701 | $966 | 138 | - | - | - | - |
$3,241 84,701 kWh |
$966 138 kW-months/year |
- - $ |
- - lb |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
03: 2.6231 UTILIZE CONTROLS TO OPERATE EQUIPMENT ONLY WHEN NEEDED |
Savings: $2,405 Cost: $1,100 |
$1,778 | 46,600 | $627 | 90 | - | - | - | - |
$1,778 46,600 kWh |
$627 90 kW-months/year |
- - $ |
- - lb |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
04: 2.4239 ELIMINATE OR REDUCE COMPRESSED AIR USAGE |
Savings: $1,977 Cost: - |
$1,522 | 39,859 | $455 | 65 | - | - | - | - |
$1,522 39,859 kWh |
$455 65 kW-months/year |
- - $ |
- - lb |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
05: 2.4133 USE MOST EFFICIENT TYPE OF ELECTRIC MOTORS |
Savings: $977 Cost: $1,439 |
$723 | 18,757 | $254 | 36 | - | - | - | - |
$723 18,757 kWh |
$254 36 kW-months/year |
- - $ |
- - lb |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
06: 2.3212 OPTIMIZE PLANT POWER FACTOR |
Savings: $3,156 Cost: $5,517 |
- | - | - | - | $3,156 | - | - | - |
- - kWh |
- - kW-months/year |
$3,156 - $ |
- - lb |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
07: 2.6231 UTILIZE CONTROLS TO OPERATE EQUIPMENT ONLY WHEN NEEDED |
Savings: $1,452 Cost: $2,550 |
$1,452 | 37,808 | - | - | - | - | - | - |
$1,452 37,808 kWh |
- - kW-months/year |
- - $ |
- - lb |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
08: 2.7142 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS |
Savings: $6,589 Cost: $21,750 |
$4,797 | 125,147 | $1,792 | 256 | - | - | - | - |
$4,797 125,147 kWh |
$1,792 256 kW-months/year |
- - $ |
- - lb |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
09: 2.7142 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS |
Savings: $1,339 Cost: $1,339 |
$989 | 25,791 | $350 | 50 | - | - | - | - |
$989 25,791 kWh |
$350 50 kW-months/year |
- - $ |
- - lb |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
10: 3.5313 INCREASE AMOUNT OF WASTE RECOVERED FOR RESALE |
Savings: $2,606 Cost: - |
- | - | - | - | - | - | $2,606 | - |
- - kWh |
- - kW-months/year |
- - $ |
$2,606 - lb |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
11: 3.5315 LEASE / PURCHASE BALER; SELL CARDBOARD TO RECYCLER |
Savings: $2,850 Cost: $250 |
- | - | - | - | - | - | $2,850 | - |
- - kWh |
- - kW-months/year |
- - $ |
$2,850 - lb |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
TOTAL RECOMMENDED |
Savings: $34,278 Cost: $35,345 |
$19,676 | 513,774 | $5,990 | 856 | $3,156 | - | $5,456 | - | $19,676 513,774 kWh |
$5,990 856 kW-months/year |
$3,156 - $ |
$5,456 - lb |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
TOTAL IMPLEMENTED |
Savings: $26,417 Cost: $33,995 |
$17,898 | 467,174 | $5,363 | 766 | $3,156 | - | - | - | $17,898 467,174 kWh |
$5,363 766 kW-months/year |
$3,156 - $ |
- - lb |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
Savings Cost |
$ | kWh | $ | kW-months/year | $ | $ | $ | lb | |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
Electricity Usage | Electricity Demand | Electricity Fees | Solid Waste (non-haz) | Electricity Usage | Electricity Demand | Electricity Fees | Solid Waste (non-haz) |