Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
IAC Center | San Francisco State University |
---|---|
Assessment Year | 2000 |
Principal Product | Salty Snacks |
NAICS | n/a |
SIC | 2096 - Potato Chips And Similar Snacks |
Sales | $50,000,000-$100,000,000 |
# of Employees | 180 |
Plant Area (Sq.Ft.) | 124,000 |
Annual Production | 20,000,000 Pounds |
Production Hrs. Annual | 5,330 |
Location (State) | CA |
Source | Yearly Cost | Usage | Unit | Unit Cost |
---|---|---|---|---|
Electricity Usage | $354,465 | 3,523,680 | kWh | $0.10 |
Electricity Demand | $106,036 | 8,823 | kW-months/year | $12.02 |
Natural Gas | $408,752 | 111,959 | MMBtu | $3.65 |
TOTAL ENERGY COSTS | $1,013,396 | |||
RECOMMENDED SAVINGS* | $152,796 | *Non-energy impacts included in savings. See recommendations below |
||
IMPLEMENTED SAVINGS* | - |
#|Description |
Savings Cost |
Status | Electricity Usage | Electricity Demand | Natural Gas | Solid Waste (non-haz) | Administrative Changes | Electricity Usage | Electricity Demand | Natural Gas | Solid Waste (non-haz) | Administrative Changes | |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
$ | kWh | $ | kW-months/year | $ | MMBtu | $ | lb | $ | $ | ||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
01: 2.2437 RECOVER WASTE HEAT FROM EQUIPMENT |
Savings: $1,959 Cost: - |
$1,319 | 21,981 | $640 | 49 | - | - | - | - | - | - |
$1,319 21,981 kWh |
$640 49 kW-months/year |
- - MMBtu |
- - lb |
- - $ |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
02: 2.7135 INSTALL OCCUPANCY SENSORS |
Savings: $2,262 Cost: $840 |
$1,522 | 25,205 | $740 | 57 | - | - | - | - | - | - |
$1,522 25,205 kWh |
$740 57 kW-months/year |
- - MMBtu |
- - lb |
- - $ |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
03: 2.4239 ELIMINATE OR REDUCE COMPRESSED AIR USAGE |
Savings: $7,576 Cost: $5,200 |
$5,098 | 84,701 | $2,478 | 191 | - | - | - | - | - | - |
$5,098 84,701 kWh |
$2,478 191 kW-months/year |
- - MMBtu |
- - lb |
- - $ |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
04: 2.2511 INSULATE BARE EQUIPMENT |
Savings: $1,075 Cost: $956 |
- | - | - | - | $1,075 | 376 | - | - | - | - |
- - kWh |
- - kW-months/year |
$1,075 376 MMBtu |
- - lb |
- - $ |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
05: 2.4133 USE MOST EFFICIENT TYPE OF ELECTRIC MOTORS |
Savings: $1,881 Cost: $2,455 |
$1,266 | 21,102 | $615 | 47 | - | - | - | - | - | - |
$1,266 21,102 kWh |
$615 47 kW-months/year |
- - MMBtu |
- - lb |
- - $ |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
06: 2.7142 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS |
Savings: $7,009 Cost: $10,260 |
$4,578 | 76,202 | $2,431 | 187 | - | - | - | - | - | - |
$4,578 76,202 kWh |
$2,431 187 kW-months/year |
- - MMBtu |
- - lb |
- - $ |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
07: 2.7142 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS |
Savings: $2,128 Cost: $6,420 |
$1,685 | 20,809 | $443 | 106 | - | - | - | - | - | - |
$1,685 20,809 kWh |
$443 106 kW-months/year |
- - MMBtu |
- - lb |
- - $ |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
08: 2.4322 USE OR REPLACE WITH ENERGY EFFICIENT SUBSTITUTES |
Savings: $21,696 Cost: $850 |
$(-144) | (-2,345) | - | - | - | - | - | - | $21,840 | - |
$(-144) (-2,345) kWh |
- - kW-months/year |
- - MMBtu |
- - lb |
$21,840 - $ |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
09: 4.131 MODIFY PROCESS TO REDUCE MATERIAL USE/COST |
Savings: $63,815 Cost: $35,960 |
- | - | - | - | - | - | $4,119 | 24,375 | $59,696 | - |
- - kWh |
- - kW-months/year |
- - MMBtu |
$4,119 24,375 lb |
$59,696 - $ |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
10: 4.711 INITIATE A TOTAL QUALITY MANAGEMENT PROGRAM |
Savings: $43,395 Cost: $130,000 |
- | - | - | - | - | - | - | - | $43,395 | - |
- - kWh |
- - kW-months/year |
- - MMBtu |
- - lb |
$43,395 - $ |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
TOTAL RECOMMENDED |
Savings: $152,796 Cost: $192,941 |
$15,324 | 247,655 | $7,347 | 637 | $1,075 | 376 | $4,119 | 24,375 | $124,931 | - | $15,324 247,655 kWh |
$7,347 637 kW-months/year |
$1,075 376 MMBtu |
$4,119 24,375 lb |
$124,931 - $ |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
TOTAL IMPLEMENTED |
Savings: - Cost: - |
- | - | - | - | - | - | - | - | - | - | - - kWh |
- - kW-months/year |
- - MMBtu |
- - lb |
- - $ |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
Savings Cost |
$ | kWh | $ | kW-months/year | $ | MMBtu | $ | lb | $ | $ | |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
Electricity Usage | Electricity Demand | Natural Gas | Solid Waste (non-haz) | Administrative Changes | Electricity Usage | Electricity Demand | Natural Gas | Solid Waste (non-haz) | Administrative Changes |