IAC logo
IAC Assessment: SF0189
Sponsored by:
DOE MESC
IAC logo
IAC Assessment: SF0189
Implementation Grant Funding Opportunity Open
IMPORTANT: The grant program operates on a rolling basis and applications may be submitted at any time, with quarterly reviews.
Learn More
Implementation Grant Funding Opportunity Open
Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
IAC Center San Francisco State University
Assessment Year 2000
Principal Product Carbonated Beverages
NAICS n/a
SIC 2032 - Canned Specialties
Sales $10,000,000-$50,000,000
# of Employees 50
Plant Area (Sq.Ft.) 168,164
Annual Production 3,600,000 Units
Production Hrs. Annual 3,570
Location (State) CA
Source Yearly Cost Usage Unit Unit Cost
Electricity Usage $268,476 2,417,462 kWh $0.11
Natural Gas $30,613 5,116 MMBtu $5.98
TOTAL ENERGY COSTS $357,089
RECOMMENDED SAVINGS* $93,856 *Non-energy impacts
included in savings.
See recommendations below
IMPLEMENTED SAVINGS* $51,949
#|Description Savings
Cost
Status Electricity Usage Solid Waste (non-haz) Administrative Changes Electricity Usage Solid Waste (non-haz) Administrative Changes
$ kWh $ lb $ $
01: 2.1121 USE INSULATION IN FURNACES TO FACILITATE HEATING / COOLING Savings:
$8,181
Cost:
$8,239
$8,181 102,440 - - - - $8,181
102,440
kWh
-
-
lb
-
-
$
02: 2.4239 ELIMINATE OR REDUCE COMPRESSED AIR USAGE Savings:
$9,998
Cost:
$7,800
$9,998 94,491 - - - - $9,998
94,491
kWh
-
-
lb
-
-
$
03: 2.4133 USE MOST EFFICIENT TYPE OF ELECTRIC MOTORS Savings:
$807
Cost:
$1,711
$807 12,895 - - - - $807
12,895
kWh
-
-
lb
-
-
$
04: 2.7135 INSTALL OCCUPANCY SENSORS Savings:
$1,491
Cost:
$2,520
$1,491 13,227 - - - - $1,491
13,227
kWh
-
-
lb
-
-
$
05: 4.1110 ADD EQUIPMENT/ OPERATORS TO REDUCE PRODUCTION BOTTLENECK Savings:
$8,916
Cost:
$14,480
$8,916 59,619 - - - - $8,916
59,619
kWh
-
-
lb
-
-
$
06: 2.7142 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS Savings:
$9,102
Cost:
$36,670
$9,102 75,951 - - - - $9,102
75,951
kWh
-
-
lb
-
-
$
07: 3.4151 MINIMIZE WATER USAGE Savings:
$23,452
Cost:
$125,000
- - $23,452 - - - -
-
kWh
$23,452
-
lb
-
-
$
08: 2.8114 CHANGE RATE SCHEDULES OR OTHER CHANGES IN UTILITY SERVICE Savings:
$31,909
Cost:
$130,000
- - - - $31,909 - -
-
kWh
-
-
lb
$31,909
-
$
TOTAL RECOMMENDED Savings:
$93,856
Cost:
$326,420
$38,495 358,623 $23,452 - $31,909 - $38,495
358,623
kWh
$23,452
-
lb
$31,909
-
$
TOTAL IMPLEMENTED Savings:
$51,949
Cost:
$188,620
$28,497 264,132 $23,452 - - - $28,497
264,132
kWh
$23,452
-
lb
-
-
$
Savings
Cost
$ kWh $ lb $ $
Electricity Usage Solid Waste (non-haz) Administrative Changes Electricity Usage Solid Waste (non-haz) Administrative Changes