Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
IAC Center | San Francisco State University |
---|---|
Assessment Year | 2000 |
Principal Product | Plastic Pails |
NAICS | n/a |
SIC | 3079 - |
Sales | $10,000,000-$50,000,000 |
# of Employees | 96 |
Plant Area (Sq.Ft.) | 46,368 |
Annual Production | 6,000,000 Units |
Production Hrs. Annual | 8,736 |
Location (State) | CA |
Source | Yearly Cost | Usage | Unit | Unit Cost |
---|---|---|---|---|
Electricity Usage | $637,523 | 11,693,269 | kWh | $0.05 |
Natural Gas | $10,520 | 1,651 | MMBtu | $6.37 |
TOTAL ENERGY COSTS | $665,645 | |||
RECOMMENDED SAVINGS* | $90,893 | *Non-energy impacts included in savings. See recommendations below |
||
IMPLEMENTED SAVINGS* | $31,979 |
#|Description |
Savings Cost |
Status | Electricity Usage | Solid Waste (non-haz) | Administrative Changes | Electricity Usage | Solid Waste (non-haz) | Administrative Changes | |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
$ | kWh | $ | lb | $ | $ | ||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
01: 3.7392 APPLY A PROTECTIVE COATING TO RACKS AND TANKS |
Savings: $1,878 Cost: - |
$1,878 | 36,048 | - | - | - | - |
$1,878 36,048 kWh |
- - lb |
- - $ |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
02: 4.711 INITIATE A TOTAL QUALITY MANAGEMENT PROGRAM |
Savings: $834 Cost: - |
$834 | 19,500 | - | - | - | - |
$834 19,500 kWh |
- - lb |
- - $ |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
03: 2.7135 INSTALL OCCUPANCY SENSORS |
Savings: $7,130 Cost: $977 |
$7,130 | 166,642 | - | - | - | - |
$7,130 166,642 kWh |
- - lb |
- - $ |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
04: 2.4222 INSTALL ADEQUATE DRYERS ON AIR LINES TO ELIMINATE BLOWDOWN |
Savings: $5,706 Cost: $2,936 |
$5,706 | 133,358 | - | - | - | - |
$5,706 133,358 kWh |
- - lb |
- - $ |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
05: 2.7135 INSTALL OCCUPANCY SENSORS |
Savings: $1,053 Cost: $600 |
$1,053 | 24,601 | - | - | - | - |
$1,053 24,601 kWh |
- - lb |
- - $ |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
06: 2.4133 USE MOST EFFICIENT TYPE OF ELECTRIC MOTORS |
Savings: $3,000 Cost: $3,333 |
$3,000 | 57,441 | - | - | - | - |
$3,000 57,441 kWh |
- - lb |
- - $ |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
07: 2.7142 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS |
Savings: $14,489 Cost: $22,680 |
$14,489 | 338,641 | - | - | - | - |
$14,489 338,641 kWh |
- - lb |
- - $ |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
08: 2.4111 UTILIZE ENERGY-EFFICIENT BELTS AND OTHER IMPROVED MECHANISMS |
Savings: $233 Cost: $228 |
$233 | 4,396 | - | - | - | - |
$233 4,396 kWh |
- - lb |
- - $ |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
09: 2.7135 INSTALL OCCUPANCY SENSORS |
Savings: $565 Cost: $1,500 |
$565 | 13,209 | - | - | - | - |
$565 13,209 kWh |
- - lb |
- - $ |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
10: 2.4146 USE ADJUSTABLE FREQUENCY DRIVE OR MULTIPLE SPEED MOTORS ON EXISTING SYSTEM |
Savings: $51,408 Cost: $178,376 |
$51,408 | 1,201,533 | - | - | - | - |
$51,408 1,201,533 kWh |
- - lb |
- - $ |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
11: 3.5217 REUSE / RECYCLE/ SELL PAPER PRODUCTS |
Savings: $1,800 Cost: - |
- | - | $1,800 | 24 | - | - |
- - kWh |
$1,800 24 lb |
- - $ |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
12: 2.3212 OPTIMIZE PLANT POWER FACTOR |
Savings: $2,797 Cost: $6,436 |
- | - | - | - | $2,797 | - |
- - kWh |
- - lb |
$2,797 - $ |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
TOTAL RECOMMENDED |
Savings: $90,893 Cost: $217,066 |
$86,296 | 1,995,369 | $1,800 | 24 | $2,797 | - | $86,296 1,995,369 kWh |
$1,800 24 lb |
$2,797 - $ |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
TOTAL IMPLEMENTED |
Savings: $31,979 Cost: $35,754 |
$29,182 | 660,478 | - | - | $2,797 | - | $29,182 660,478 kWh |
- - lb |
$2,797 - $ |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
Savings Cost |
$ | kWh | $ | lb | $ | $ | |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||