Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
IAC Center | San Francisco State University |
---|---|
Assessment Year | 2002 |
Principal Product | Rubber Flooring |
NAICS | n/a |
SIC | 3061 - Mechanical Rubber Goods |
Sales | $50,000,000-$100,000,000 |
# of Employees | 230 |
Plant Area (Sq.Ft.) | 120,000 |
Annual Production | 0 Units |
Production Hrs. Annual | 4,250 |
Location (State) | CA |
Source | Yearly Cost | Usage | Unit | Unit Cost |
---|---|---|---|---|
Electricity Usage | $546,852 | 5,248,140 | kWh | $0.10 |
Electricity Demand | $175,474 | 17,509 | kW-months/year | $10.02 |
Natural Gas | $124,478 | 29,289 | MMBtu | $4.25 |
TOTAL ENERGY COSTS | $947,330 | |||
RECOMMENDED SAVINGS* | $186,293 | *Non-energy impacts included in savings. See recommendations below |
||
IMPLEMENTED SAVINGS* | $19,092 |
#|Description |
Savings Cost |
Status | Electricity Usage | Electricity Fees | Natural Gas | Solid Waste (non-haz) | Administrative Changes | Electricity Usage | Electricity Fees | Natural Gas | Solid Waste (non-haz) | Administrative Changes | |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
$ | kWh | $ | $ | $ | MMBtu | $ | lb | $ | $ | ||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
01: 2.1233 ANALYZE FLUE GAS FOR PROPER AIR/FUEL RATIO |
Savings: $7,917 Cost: $7,200 |
- | - | - | - | $7,917 | 1,863 | - | - | - | - |
- - kWh |
- - $ |
$7,917 1,863 MMBtu |
- - lb |
- - $ |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
02: 2.7132 INSTALL TIMERS ON LIGHT SWITCHES IN LITTLE USED AREAS |
Savings: $3,065 Cost: $4,060 |
$3,065 | 29,415 | - | - | - | - | - | - | - | - |
$3,065 29,415 kWh |
- - $ |
- - MMBtu |
- - lb |
- - $ |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
03: 2.4133 USE MOST EFFICIENT TYPE OF ELECTRIC MOTORS |
Savings: $2,576 Cost: $4,115 |
$2,576 | 18,948 | - | - | - | - | - | - | - | - |
$2,576 18,948 kWh |
- - $ |
- - MMBtu |
- - lb |
- - $ |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
04: 2.4226 USE / PURCHASE OPTIMUM SIZED COMPRESSOR |
Savings: $8,585 Cost: $20,725 |
$8,585 | 71,431 | - | - | - | - | - | - | - | - |
$8,585 71,431 kWh |
- - $ |
- - MMBtu |
- - lb |
- - $ |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
05: 2.7491 INSULATE GLAZING, WALLS, CEILINGS, AND ROOFS |
Savings: $19,484 Cost: $97,649 |
$19,484 | 152,021 | - | - | - | - | - | - | - | - |
$19,484 152,021 kWh |
- - $ |
- - MMBtu |
- - lb |
- - $ |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
06: 3.6192 USE A LESS EXPENSIVE METHOD OF WASTE REMOVAL |
Savings: $2,738 Cost: $6,972 |
- | - | - | - | - | - | $2,738 | - | - | - |
- - kWh |
- - $ |
- - MMBtu |
$2,738 - lb |
- - $ |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
07: 2.3131 RESCHEDULE PLANT OPERATIONS OR REDUCE LOAD TO AVOID PEAKS |
Savings: $5,193 Cost: - |
- | - | $5,193 | - | - | - | - | - | - | - |
- - kWh |
$5,193 - $ |
- - MMBtu |
- - lb |
- - $ |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
08: 2.8114 CHANGE RATE SCHEDULES OR OTHER CHANGES IN UTILITY SERVICE |
Savings: $74,335 Cost: $160,000 |
- | - | $74,335 | - | - | - | - | - | - | - |
- - kWh |
$74,335 - $ |
- - MMBtu |
- - lb |
- - $ |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
09: 4.441 INSTALL AUTOMATIC PACKING EQUIPMENT |
Savings: $62,400 Cost: $250,000 |
- | - | - | - | - | - | - | - | $62,400 | - |
- - kWh |
- - $ |
- - MMBtu |
- - lb |
$62,400 - $ |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
TOTAL RECOMMENDED |
Savings: $186,293 Cost: $550,721 |
$33,710 | 271,815 | $79,528 | - | $7,917 | 1,863 | $2,738 | - | $62,400 | - | $33,710 271,815 kWh |
$79,528 - $ |
$7,917 1,863 MMBtu |
$2,738 - lb |
$62,400 - $ |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
TOTAL IMPLEMENTED |
Savings: $19,092 Cost: $31,812 |
$11,161 | 90,379 | $5,193 | - | - | - | $2,738 | - | - | - | $11,161 90,379 kWh |
$5,193 - $ |
- - MMBtu |
$2,738 - lb |
- - $ |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
Savings Cost |
$ | kWh | $ | $ | $ | MMBtu | $ | lb | $ | $ | |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
Electricity Usage | Electricity Fees | Natural Gas | Solid Waste (non-haz) | Administrative Changes | Electricity Usage | Electricity Fees | Natural Gas | Solid Waste (non-haz) | Administrative Changes |