Implementation Grant Funding Opportunity Open
IMPORTANT: The grant program operates on a rolling basis and applications may be submitted at any time, with quarterly reviews.
Learn More
Implementation Grant Funding Opportunity Open
Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
IAC Center | San Francisco State University |
---|---|
Assessment Year | 2005 |
Principal Product | tomato sauce |
NAICS | 311421 - Fruit and Vegetable Canning |
SIC | 2003 - |
Sales | $50,000,000-$100,000,000 |
# of Employees | 400 |
Plant Area (Sq.Ft.) | 896,465 |
Annual Production | 400,000 Tons |
Production Hrs. Annual | 3,616 |
Location (State) | CA |
Source | Yearly Cost | Usage | Unit | Unit Cost |
---|---|---|---|---|
Electricity Usage | $1,096,481 | 10,353,000 | kWh | $0.11 |
Natural Gas | $1,000,000 | 773,033 | MMBtu | $1.29 |
TOTAL ENERGY COSTS | $3,096,481 | |||
RECOMMENDED SAVINGS* | $308,462 | *Non-energy impacts included in savings. See recommendations below |
||
IMPLEMENTED SAVINGS* | $3,253 |
#|Description |
Savings Cost |
Status | Electricity Usage | Electricity Demand | Natural Gas | Water Disposal | Solid Waste (non-haz) | One-time Revenue or Avoided Cost | Electricity Usage | Electricity Demand | Natural Gas | Water Disposal | Solid Waste (non-haz) | One-time Revenue or Avoided Cost | |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
$ | kWh | $ | kW-months/year | $ | MMBtu | $ | Tgal | $ | lb | $ | $ | ||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
01: 2.4236 ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES |
Savings: $3,253 Cost: $924 |
$3,253 | 49,321 | - | - | - | - | - | - | - | - | - | - |
$3,253 49,321 kWh |
- - kW-months/year |
- - MMBtu |
- - Tgal |
- - lb |
- - $ |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
02: 2.2414 USE WASTE HEAT FROM HOT FLUE GASES TO PREHEAT |
Savings: $46,562 Cost: $7,250 |
- | - | - | - | $46,562 | 6,162 | - | - | - | - | - | - |
- - kWh |
- - kW-months/year |
$46,562 6,162 MMBtu |
- - Tgal |
- - lb |
- - $ |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
03: 2.2136 INSTALL / REPAIR INSULATION ON STEAM LINES |
Savings: $7,245 Cost: $4,237 |
- | - | - | - | $7,245 | 953 | - | - | - | - | - | - |
- - kWh |
- - kW-months/year |
$7,245 953 MMBtu |
- - Tgal |
- - lb |
- - $ |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
04: 2.4146 USE ADJUSTABLE FREQUENCY DRIVE OR MULTIPLE SPEED MOTORS ON EXISTING SYSTEM |
Savings: $127,648 Cost: $99,552 |
$31,432 | 371,100 | $4,968 | 522 | $91,248 | 12,006 | - | - | - | - | - | - |
$31,432 371,100 kWh |
$4,968 522 kW-months/year |
$91,248 12,006 MMBtu |
- - Tgal |
- - lb |
- - $ |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
05: 2.4146 USE ADJUSTABLE FREQUENCY DRIVE OR MULTIPLE SPEED MOTORS ON EXISTING SYSTEM |
Savings: $14,088 Cost: $22,853 |
$11,658 | 108,947 | $2,430 | 270 | - | - | - | - | - | - | - | - |
$11,658 108,947 kWh |
$2,430 270 kW-months/year |
- - MMBtu |
- - Tgal |
- - lb |
- - $ |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
06: 2.7135 INSTALL OCCUPANCY SENSORS |
Savings: $1,408 Cost: $2,520 |
$1,039 | 7,914 | $369 | 41 | - | - | - | - | - | - | - | - |
$1,039 7,914 kWh |
$369 41 kW-months/year |
- - MMBtu |
- - Tgal |
- - lb |
- - $ |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
07: 2.7142 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS |
Savings: $3,215 Cost: $6,387 |
$2,580 | 22,257 | $635 | 71 | - | - | - | - | - | - | - | - |
$2,580 22,257 kWh |
$635 71 kW-months/year |
- - MMBtu |
- - Tgal |
- - lb |
- - $ |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
08: 2.7111 REDUCE ILLUMINATION TO MINIMUM NECESSARY LEVELS |
Savings: $5,345 Cost: $13,619 |
$4,260 | 36,327 | $1,085 | 121 | - | - | - | - | - | - | - | - |
$4,260 36,327 kWh |
$1,085 121 kW-months/year |
- - MMBtu |
- - Tgal |
- - lb |
- - $ |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
09: 2.4133 USE MOST EFFICIENT TYPE OF ELECTRIC MOTORS |
Savings: $11,916 Cost: $18,347 |
$5,958 | 56,941 | $5,958 | 126 | - | - | - | - | - | - | - | - |
$5,958 56,941 kWh |
$5,958 126 kW-months/year |
- - MMBtu |
- - Tgal |
- - lb |
- - $ |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
10: 2.8114 CHANGE RATE SCHEDULES OR OTHER CHANGES IN UTILITY SERVICE |
Savings: $35,920 Cost: $138,400 |
- | - | - | - | - | - | - | - | - | - | $35,920 | - |
- - kWh |
- - kW-months/year |
- - MMBtu |
- - Tgal |
- - lb |
$35,920 - $ |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
11: 3.5313 INCREASE AMOUNT OF WASTE RECOVERED FOR RESALE |
Savings: $29,001 Cost: - |
- | - | - | - | - | - | - | - | $29,001 | - | - | - |
- - kWh |
- - kW-months/year |
- - MMBtu |
- - Tgal |
$29,001 - lb |
- - $ |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
12: 3.5315 LEASE / PURCHASE BALER; SELL CARDBOARD TO RECYCLER |
Savings: $5,421 Cost: $385 |
- | - | - | - | - | - | - | - | $5,421 | 120,000 | - | - |
- - kWh |
- - kW-months/year |
- - MMBtu |
- - Tgal |
$5,421 120,000 lb |
- - $ |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
13: 3.4115 RECOVER AND REUSE COOLING WATER |
Savings: $17,440 Cost: $8,393 |
- | - | - | - | - | - | $17,440 | 9,112 | - | - | - | - |
- - kWh |
- - kW-months/year |
- - MMBtu |
$17,440 9,112 Tgal |
- - lb |
- - $ |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
TOTAL RECOMMENDED |
Savings: $308,462 Cost: $322,867 |
$60,180 | 652,807 | $15,445 | 1,151 | $145,055 | 19,121 | $17,440 | 9,112 | $34,422 | 120,000 | $35,920 | - | $60,180 652,807 kWh |
$15,445 1,151 kW-months/year |
$145,055 19,121 MMBtu |
$17,440 9,112 Tgal |
$34,422 120,000 lb |
$35,920 - $ |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
TOTAL IMPLEMENTED |
Savings: $3,253 Cost: $924 |
$3,253 | 49,321 | - | - | - | - | - | - | - | - | - | - | $3,253 49,321 kWh |
- - kW-months/year |
- - MMBtu |
- - Tgal |
- - lb |
- - $ |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
Savings Cost |
$ | kWh | $ | kW-months/year | $ | MMBtu | $ | Tgal | $ | lb | $ | $ | |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
Electricity Usage | Electricity Demand | Natural Gas | Water Disposal | Solid Waste (non-haz) | One-time Revenue or Avoided Cost | Electricity Usage | Electricity Demand | Natural Gas | Water Disposal | Solid Waste (non-haz) | One-time Revenue or Avoided Cost |