IAC logo
IAC Assessment: SF0319
Sponsored by:
DOE MESC
IAC logo
IAC Assessment: SF0319
Implementation Grant Funding Opportunity Open
IMPORTANT: The grant program operates on a rolling basis and applications may be submitted at any time, with quarterly reviews.
Learn More
Implementation Grant Funding Opportunity Open
Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
IAC Center San Francisco State University
Assessment Year 2006
Principal Product Bell Pepper and Cabbage
NAICS 311411 - Frozen Fruit, Juice, and Vegetable Manufacturing
SIC 2037 - Frozen Fruits And Vegetables
Sales $10,000,000-$50,000,000
# of Employees 350
Plant Area (Sq.Ft.) 50,000
Annual Production 7,599 Tons
Production Hrs. Annual 3,360
Location (State) CA
Source Yearly Cost Usage Unit Unit Cost
Electricity Usage $378,747 4,777,432 kWh $0.08
Electricity Demand $220,542 14,857 kW-months/year $14.84
Natural Gas $153,385 20,366 MMBtu $7.53
TOTAL ENERGY COSTS $840,557
RECOMMENDED SAVINGS* $65,050 *Non-energy impacts
included in savings.
See recommendations below
IMPLEMENTED SAVINGS* $45,101
#|Description Savings
Cost
Status Electricity Usage Electricity Demand Electricity Usage Electricity Demand
$ kWh $ kW-months/year
01: 2.7134 USE PHOTOCELL CONTROLS Savings:
$381
Cost:
$360
$304 3,851 $77 5 $304
3,851
kWh
$77
5
kW-months/year
02: 2.6231 UTILIZE CONTROLS TO OPERATE EQUIPMENT ONLY WHEN NEEDED Savings:
$19,568
Cost:
$19,053
$19,568 247,081 - - $19,568
247,081
kWh
-
-
kW-months/year
03: 2.4322 USE OR REPLACE WITH ENERGY EFFICIENT SUBSTITUTES Savings:
$18,204
Cost:
$20,250
$13,049 1,647,665 $5,155 347 $13,049
1,647,665
kWh
$5,155
347
kW-months/year
04: 2.4133 USE MOST EFFICIENT TYPE OF ELECTRIC MOTORS Savings:
$18,411
Cost:
$23,058
$11,018 139,486 $7,393 498 $11,018
139,486
kWh
$7,393
498
kW-months/year
05: 2.7142 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS Savings:
$5,934
Cost:
$18,325
$3,619 45,690 $2,315 156 $3,619
45,690
kWh
$2,315
156
kW-months/year
06: 2.4111 UTILIZE ENERGY-EFFICIENT BELTS AND OTHER IMPROVED MECHANISMS Savings:
$2,552
Cost:
$4,648
$1,309 16,532 $1,243 84 $1,309
16,532
kWh
$1,243
84
kW-months/year
TOTAL RECOMMENDED Savings:
$65,050
Cost:
$85,694
$48,867 2,100,305 $16,183 1,090 $48,867
2,100,305
kWh
$16,183
1,090
kW-months/year
TOTAL IMPLEMENTED Savings:
$45,101
Cost:
$66,281
$28,995 1,849,373 $16,106 1,085 $28,995
1,849,373
kWh
$16,106
1,085
kW-months/year
Savings
Cost
$ kWh $ kW-months/year
Electricity Usage Electricity Demand Electricity Usage Electricity Demand