Implementation Grant Funding Opportunity Open
IMPORTANT: The grant program operates on a rolling basis and applications may be submitted at any time, with quarterly reviews.
Learn More
Implementation Grant Funding Opportunity Open
Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
IAC Center | San Francisco State University |
---|---|
Assessment Year | 2007 |
Principal Product | Packaged Produce |
NAICS | 115114 - Postharvest Crop Activities (except Cotton Ginning) |
SIC | 723 - Beauty Shops |
Sales | $100,000,000-$500,000,000 |
# of Employees | 600 |
Plant Area (Sq.Ft.) | 125,000 |
Annual Production | 357,000,000 Pounds |
Production Hrs. Annual | 4,080 |
Location (State) | CA |
Source | Yearly Cost | Usage | Unit | Unit Cost |
---|---|---|---|---|
Electricity Usage | $1,645,617 | 20,069,749 | kWh | $0.08 |
Electricity Demand | $587,059 | 40,259 | kW-months/year | $14.58 |
TOTAL ENERGY COSTS | $2,674,267 | |||
RECOMMENDED SAVINGS* | $721,631 | *Non-energy impacts included in savings. See recommendations below |
||
IMPLEMENTED SAVINGS* | $440,697 |
#|Description |
Savings Cost |
Status | Electricity Usage | Electricity Demand | Solid Waste (non-haz) | Electricity Usage | Electricity Demand | Solid Waste (non-haz) | |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
$ | kWh | $ | kW-months/year | $ | lb | ||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
01: 2.7142 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS |
Savings: $1,653 Cost: $244 |
$1,128 | 14,256 | $525 | 35 | - | - |
$1,128 14,256 kWh |
$525 35 kW-months/year |
- - lb |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
02: 2.2628 UTILIZE A LESS EXPENSIVE COOLING METHOD |
Savings: $229,277 Cost: $80,000 |
$163,938 | 2,071,968 | $65,339 | 4,352 | - | - |
$163,938 2,071,968 kWh |
$65,339 4,352 kW-months/year |
- - lb |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
03: 2.4133 USE MOST EFFICIENT TYPE OF ELECTRIC MOTORS |
Savings: $9,563 Cost: $2,639 |
$6,138 | 77,576 | $3,425 | 228 | - | - |
$6,138 77,576 kWh |
$3,425 228 kW-months/year |
- - lb |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
04: 2.4235 REMOVE OR CLOSE OFF UNNEEDED COMPRESSED AIR LINES |
Savings: $8,934 Cost: $2,310 |
$8,934 | 112,918 | - | - | - | - |
$8,934 112,918 kWh |
- - kW-months/year |
- - lb |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
05: 2.4146 USE ADJUSTABLE FREQUENCY DRIVE OR MULTIPLE SPEED MOTORS ON EXISTING SYSTEM |
Savings: $12,287 Cost: $5,129 |
$9,551 | 115,706 | $2,736 | 182 | - | - |
$9,551 115,706 kWh |
$2,736 182 kW-months/year |
- - lb |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
06: 2.7442 KEEP DOORS AND WINDOWS SHUT WHEN NOT ON USE |
Savings: $46,653 Cost: $25,591 |
$34,389 | 434,652 | $12,264 | 817 | - | - |
$34,389 434,652 kWh |
$12,264 817 kW-months/year |
- - lb |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
07: 2.7142 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS |
Savings: $5,837 Cost: $3,351 |
$3,843 | 48,565 | $1,994 | 133 | - | - |
$3,843 48,565 kWh |
$1,994 133 kW-months/year |
- - lb |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
08: 2.4146 USE ADJUSTABLE FREQUENCY DRIVE OR MULTIPLE SPEED MOTORS ON EXISTING SYSTEM |
Savings: $32,070 Cost: $22,400 |
$32,070 | 405,325 | - | - | - | - |
$32,070 405,325 kWh |
- - kW-months/year |
- - lb |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
09: 2.4146 USE ADJUSTABLE FREQUENCY DRIVE OR MULTIPLE SPEED MOTORS ON EXISTING SYSTEM |
Savings: $2,014 Cost: $5,542 |
$2,014 | 25,462 | - | - | - | - |
$2,014 25,462 kWh |
- - kW-months/year |
- - lb |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
10: 2.7142 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS |
Savings: $754 Cost: $2,432 |
$510 | 6,977 | $244 | 17 | - | - |
$510 6,977 kWh |
$244 17 kW-months/year |
- - lb |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
11: 2.2136 INSTALL / REPAIR INSULATION ON STEAM LINES |
Savings: $519 Cost: $2,033 |
$519 | 6,560 | - | - | - | - |
$519 6,560 kWh |
- - kW-months/year |
- - lb |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
12: 2.2136 INSTALL / REPAIR INSULATION ON STEAM LINES |
Savings: $2,832 Cost: $14,632 |
$2,832 | 35,796 | - | - | - | - |
$2,832 35,796 kWh |
- - kW-months/year |
- - lb |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
13: 2.4131 SIZE ELECTRIC MOTORS FOR PEAK OPERATING EFFICIENCY |
Savings: $58,477 Cost: $704,893 |
$58,477 | 688,480 | - | - | - | - |
$58,477 688,480 kWh |
- - kW-months/year |
- - lb |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
14: 3.1161 ELIMINATE/REDUCE AN OPERATION |
Savings: $123,261 Cost: $24,000 |
- | - | - | - | $123,261 | - |
- - kWh |
- - kW-months/year |
$123,261 - lb |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
15: 3.1161 ELIMINATE/REDUCE AN OPERATION |
Savings: $187,500 Cost: $16,945 |
- | - | - | - | $187,500 | - |
- - kWh |
- - kW-months/year |
$187,500 - lb |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
TOTAL RECOMMENDED |
Savings: $721,631 Cost: $912,141 |
$324,343 | 4,044,241 | $86,527 | 5,764 | $310,761 | - | $324,343 4,044,241 kWh |
$86,527 5,764 kW-months/year |
$310,761 - lb |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
TOTAL IMPLEMENTED |
Savings: $440,697 Cost: $789,641 |
$121,537 | 1,481,009 | $8,399 | 560 | $310,761 | - | $121,537 1,481,009 kWh |
$8,399 560 kW-months/year |
$310,761 - lb |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
Savings Cost |
$ | kWh | $ | kW-months/year | $ | lb | |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
Electricity Usage | Electricity Demand | Solid Waste (non-haz) | Electricity Usage | Electricity Demand | Solid Waste (non-haz) |