Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
IAC Center San Francisco State University
Assessment Year 2010
Principal Product Chocolate
NAICS 311351 - Chocolate and Confectionery Manufacturing from Cacao Beans
SIC 2066 - Chocolate And Cocoa Products
Sales $100,000,000-$500,000,000
# of Employees 110
Plant Area (Sq.Ft.) 120,000
Annual Production 1,000 Units
Production Hrs. Annual 8,736
Location (State) CA
Source Yearly Cost Usage Unit Unit Cost
Electricity Usage $1,403,559 16,486,181 kWh $0.09
Electricity Demand $469,385 78,217 kW-months/year $6.00
Natural Gas $393,703 33,144 MMBtu $11.88
TOTAL ENERGY COSTS $2,266,647
RECOMMENDED SAVINGS* $288,381 *Non-energy impacts
included in savings.
See recommendations below
IMPLEMENTED SAVINGS* $99,723
#|Description Savings
Cost
Status Electricity Usage Electricity Demand Natural Gas Electricity Usage Electricity Demand Natural Gas
$ kWh $ kW-months/year $ MMBtu
01: 2.2135 REPAIR AND ELIMINATE STEAM LEAKS Savings:
$9,146
Cost:
$2,700
- - - - $9,146 759 -
-
kWh
-
-
kW-months/year
$9,146
759
MMBtu
02: 2.4146 USE ADJUSTABLE FREQUENCY DRIVE OR MULTIPLE SPEED MOTORS ON EXISTING SYSTEM Savings:
$10,775
Cost:
$7,837
$10,775 114,199 - - - - $10,775
114,199
kWh
-
-
kW-months/year
-
-
MMBtu
03: 2.4111 UTILIZE ENERGY-EFFICIENT BELTS AND OTHER IMPROVED MECHANISMS Savings:
$1,878
Cost:
$1,247
$1,878 14,994 - - - - $1,878
14,994
kWh
-
-
kW-months/year
-
-
MMBtu
04: 2.2511 INSULATE BARE EQUIPMENT Savings:
$53,897
Cost:
$49,178
$49,126 520,682 $4,771 715 - - $49,126
520,682
kWh
$4,771
715
kW-months/year
-
-
MMBtu
05: 2.7134 USE PHOTOCELL CONTROLS Savings:
$4,141
Cost:
$6,637
$4,141 33,355 - - - - $4,141
33,355
kWh
-
-
kW-months/year
-
-
MMBtu
06: 2.4133 USE MOST EFFICIENT TYPE OF ELECTRIC MOTORS Savings:
$4,265
Cost:
$8,098
$4,265 45,252 - - - - $4,265
45,252
kWh
-
-
kW-months/year
-
-
MMBtu
07: 2.4234 COOL COMPRESSOR AIR INTAKE WITH HEAT EXCHANGER Savings:
$10,035
Cost:
$18,281
$10,035 106,355 - - - - $10,035
106,355
kWh
-
-
kW-months/year
-
-
MMBtu
08: 2.4146 USE ADJUSTABLE FREQUENCY DRIVE OR MULTIPLE SPEED MOTORS ON EXISTING SYSTEM Savings:
$7,262
Cost:
$14,381
$7,262 76,965 - - - - $7,262
76,965
kWh
-
-
kW-months/year
-
-
MMBtu
09: 2.2314 REPLACE HEAT TREATING OVEN WITH MORE EFFICIENT UNIT Savings:
$165,218
Cost:
$158,868
$150,474 1,594,844 $14,744 2,191 - - $150,474
1,594,844
kWh
$14,744
2,191
kW-months/year
-
-
MMBtu
10: 2.7135 INSTALL OCCUPANCY SENSORS Savings:
$12,608
Cost:
$36,493
$12,608 119,278 - - - - $12,608
119,278
kWh
-
-
kW-months/year
-
-
MMBtu
11: 2.4146 USE ADJUSTABLE FREQUENCY DRIVE OR MULTIPLE SPEED MOTORS ON EXISTING SYSTEM Savings:
$733
Cost:
$2,953
$733 7,773 - - - - $733
7,773
kWh
-
-
kW-months/year
-
-
MMBtu
12: 2.7142 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS Savings:
$8,423
Cost:
$62,855
$8,423 77,248 - - - - $8,423
77,248
kWh
-
-
kW-months/year
-
-
MMBtu
TOTAL RECOMMENDED Savings:
$288,381
Cost:
$369,528
$259,720 2,710,945 $19,515 2,906 $9,146 759 $259,720
2,710,945
kWh
$19,515
2,906
kW-months/year
$9,146
759
MMBtu
TOTAL IMPLEMENTED Savings:
$99,723
Cost:
$168,653
$85,806 872,535 $4,771 715 $9,146 759 $85,806
872,535
kWh
$4,771
715
kW-months/year
$9,146
759
MMBtu
Savings
Cost
$ kWh $ kW-months/year $ MMBtu
Electricity Usage Electricity Demand Natural Gas Electricity Usage Electricity Demand Natural Gas