Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
IAC Center | San Francisco State University |
---|---|
Assessment Year | 2012 |
Principal Product | Packaged Lamb |
NAICS | 112112 - Cattle Feedlots |
SIC | 2011 - Meat Packing Plants |
Sales | $100,000,000-$500,000,000 |
# of Employees | 146 |
Plant Area (Sq.Ft.) | 300,000 |
Annual Production | 285,600 Pieces |
Production Hrs. Annual | 8,760 |
Location (State) | CA |
Source | Yearly Cost | Usage | Unit | Unit Cost |
---|---|---|---|---|
Electricity Usage | $473,261 | 5,132,994 | kWh | $0.09 |
Electricity Demand | $216,306 | 11,748 | kW-months/year | $18.41 |
Electricity Fees | $9,842 | - | $ | - |
Natural Gas | $99,372 | 19,662 | MMBtu | $5.05 |
TOTAL ENERGY COSTS | $798,781 | |||
RECOMMENDED SAVINGS* | $136,292 | *Non-energy impacts included in savings. See recommendations below |
||
IMPLEMENTED SAVINGS* | $94,322 |
#|Description |
Savings Cost |
Status | Electricity Usage | Electricity Demand | Electricity Fees | Natural Gas | Primary Raw Material | Ancillary Material Cost | Electricity Usage | Electricity Demand | Electricity Fees | Natural Gas | Primary Raw Material | Ancillary Material Cost | |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
$ | kWh | $ | kW-months/year | $ | $ | $ | MMBtu | $ | $ | $ | $ | ||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
01: 2.8112 COMBINE UTILITY METERS |
Savings: $35,266 Cost: - |
- | - | - | - | $35,266 | - | - | - | - | - | - | - |
- - kWh |
- - kW-months/year |
$35,266 - $ |
- - MMBtu |
- - $ |
- - $ |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
02: 2.4236 ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES |
Savings: $3,097 Cost: $504 |
$3,097 | 33,660 | - | - | - | - | - | - | - | - | - | - |
$3,097 33,660 kWh |
- - kW-months/year |
- - $ |
- - MMBtu |
- - $ |
- - $ |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
03: 2.6223 SCHEDULE USE OF ELEVATORS TO CONSERVE ENERGY |
Savings: $716 Cost: - |
- | - | - | - | $716 | - | - | - | - | - | - | - |
- - kWh |
- - kW-months/year |
$716 - $ |
- - MMBtu |
- - $ |
- - $ |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
04: 2.1233 ANALYZE FLUE GAS FOR PROPER AIR/FUEL RATIO |
Savings: $1,666 Cost: $1,200 |
- | - | - | - | - | - | $1,666 | 330 | - | - | - | - |
- - kWh |
- - kW-months/year |
- - $ |
$1,666 330 MMBtu |
- - $ |
- - $ |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
05: 2.4146 USE ADJUSTABLE FREQUENCY DRIVE OR MULTIPLE SPEED MOTORS ON EXISTING SYSTEM |
Savings: $19,104 Cost: $6,660 |
$19,104 | 207,654 | - | - | - | - | - | - | - | - | - | - |
$19,104 207,654 kWh |
- - kW-months/year |
- - $ |
- - MMBtu |
- - $ |
- - $ |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
06: 2.4322 USE OR REPLACE WITH ENERGY EFFICIENT SUBSTITUTES |
Savings: $1,094 Cost: $939 |
$851 | 9,255 | $243 | 13 | - | - | - | - | - | - | - | - |
$851 9,255 kWh |
$243 13 kW-months/year |
- - $ |
- - MMBtu |
- - $ |
- - $ |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
07: 2.2627 USE MULTIPLE-EFFECT EVAPORATORS |
Savings: $14,245 Cost: $17,433 |
$11,182 | 121,541 | $3,063 | 167 | - | - | - | - | - | - | - | - |
$11,182 121,541 kWh |
$3,063 167 kW-months/year |
- - $ |
- - MMBtu |
- - $ |
- - $ |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
08: 2.2437 RECOVER WASTE HEAT FROM EQUIPMENT |
Savings: $2,723 Cost: $3,965 |
- | - | - | - | - | - | $2,723 | 539 | - | - | - | - |
- - kWh |
- - kW-months/year |
- - $ |
$2,723 539 MMBtu |
- - $ |
- - $ |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
09: 2.2414 USE WASTE HEAT FROM HOT FLUE GASES TO PREHEAT |
Savings: $4,671 Cost: $11,216 |
- | - | - | - | - | - | $4,671 | 925 | - | - | - | - |
- - kWh |
- - kW-months/year |
- - $ |
$4,671 925 MMBtu |
- - $ |
- - $ |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
10: 2.7135 INSTALL OCCUPANCY SENSORS |
Savings: $18,497 Cost: $47,901 |
$13,878 | 150,843 | $4,619 | 251 | - | - | - | - | - | - | - | - |
$13,878 150,843 kWh |
$4,619 251 kW-months/year |
- - $ |
- - MMBtu |
- - $ |
- - $ |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
11: 2.2622 REPLACE EXISTING CHILLER WITH HIGH EFFICIENCY MODEL |
Savings: $1,227 Cost: $3,774 |
$963 | 10,473 | $264 | 14 | - | - | - | - | - | - | - | - |
$963 10,473 kWh |
$264 14 kW-months/year |
- - $ |
- - MMBtu |
- - $ |
- - $ |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
12: 2.7142 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS |
Savings: $33,986 Cost: $135,330 |
$22,857 | 248,440 | $9,284 | 505 | - | - | - | - | $886 | - | $959 | - |
$22,857 248,440 kWh |
$9,284 505 kW-months/year |
- - $ |
- - MMBtu |
$886 - $ |
$959 - $ |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
TOTAL RECOMMENDED |
Savings: $136,292 Cost: $228,922 |
$71,932 | 781,866 | $17,473 | 950 | $35,982 | - | $9,060 | 1,794 | $886 | - | $959 | - | $71,932 781,866 kWh |
$17,473 950 kW-months/year |
$35,982 - $ |
$9,060 1,794 MMBtu |
$886 - $ |
$959 - $ |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
TOTAL IMPLEMENTED |
Savings: $94,322 Cost: $185,874 |
$40,683 | 442,198 | $14,146 | 769 | $35,982 | - | $1,666 | 330 | $886 | - | $959 | - | $40,683 442,198 kWh |
$14,146 769 kW-months/year |
$35,982 - $ |
$1,666 330 MMBtu |
$886 - $ |
$959 - $ |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
Savings Cost |
$ | kWh | $ | kW-months/year | $ | $ | $ | MMBtu | $ | $ | $ | $ | |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
Electricity Usage | Electricity Demand | Electricity Fees | Natural Gas | Primary Raw Material | Ancillary Material Cost | Electricity Usage | Electricity Demand | Electricity Fees | Natural Gas | Primary Raw Material | Ancillary Material Cost |