Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
IAC Center | San Francisco State University |
---|---|
Assessment Year | 2012 |
Principal Product | Composite Wood Doors |
NAICS | 321911 - Wood Window and Door Manufacturing |
SIC | 2431 - Millwork |
Sales | $5,000,000-$10,000,000 |
# of Employees | 57 |
Plant Area (Sq.Ft.) | 303,000 |
Annual Production | 884,000 Pieces |
Production Hrs. Annual | 2,210 |
Location (State) | CA |
Source | Yearly Cost | Usage | Unit | Unit Cost |
---|---|---|---|---|
Electricity Usage | $212,395 | 2,465,507 | kWh | $0.09 |
Electricity Demand | $206,867 | 10,800 | kW-months/year | $19.15 |
Natural Gas | $3,706 | 389 | MMBtu | $9.53 |
TOTAL ENERGY COSTS | $422,968 | |||
RECOMMENDED SAVINGS* | $66,387 | *Non-energy impacts included in savings. See recommendations below |
||
IMPLEMENTED SAVINGS* | $13,019 |
#|Description |
Savings Cost |
Status | Electricity Usage | Electricity Demand | Administrative Changes | Primary Raw Material | One-time Revenue or Avoided Cost | Electricity Usage | Electricity Demand | Administrative Changes | Primary Raw Material | One-time Revenue or Avoided Cost | |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
$ | kWh | $ | kW-months/year | $ | $ | $ | $ | $ | $ | ||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
01: 2.3131 RESCHEDULE PLANT OPERATIONS OR REDUCE LOAD TO AVOID PEAKS |
Savings: $12,561 Cost: - |
- | - | - | - | - | - | - | - | $12,561 | - |
- - kWh |
- - kW-months/year |
- - $ |
- - $ |
$12,561 - $ |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
02: 2.4236 ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES |
Savings: $2,459 Cost: - |
$2,459 | 36,625 | - | - | - | - | - | - | - | - |
$2,459 36,625 kWh |
- - kW-months/year |
- - $ |
- - $ |
- - $ |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
03: 2.4231 REDUCE THE PRESSURE OF COMPRESSED AIR TO THE MINIMUM REQUIRED |
Savings: $915 Cost: $58 |
$413 | 4,792 | $502 | 26 | - | - | - | - | - | - |
$413 4,792 kWh |
$502 26 kW-months/year |
- - $ |
- - $ |
- - $ |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
04: 2.4111 UTILIZE ENERGY-EFFICIENT BELTS AND OTHER IMPROVED MECHANISMS |
Savings: $1,237 Cost: $239 |
$558 | 6,483 | $679 | 35 | - | - | - | - | - | - |
$558 6,483 kWh |
$679 35 kW-months/year |
- - $ |
- - $ |
- - $ |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
05: 2.4146 USE ADJUSTABLE FREQUENCY DRIVE OR MULTIPLE SPEED MOTORS ON EXISTING SYSTEM |
Savings: $37,829 Cost: $21,581 |
$17,076 | 198,238 | $20,753 | 1,076 | - | - | - | - | - | - |
$17,076 198,238 kWh |
$20,753 1,076 kW-months/year |
- - $ |
- - $ |
- - $ |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
06: 2.3131 RESCHEDULE PLANT OPERATIONS OR REDUCE LOAD TO AVOID PEAKS |
Savings: $2,063 Cost: $2,490 |
- | - | - | - | $2,063 | - | - | - | - | - |
- - kWh |
- - kW-months/year |
$2,063 - $ |
- - $ |
- - $ |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
07: 2.7135 INSTALL OCCUPANCY SENSORS |
Savings: $6,916 Cost: $31,417 |
$3,126 | 36,286 | $3,790 | 197 | - | - | - | - | - | - |
$3,126 36,286 kWh |
$3,790 197 kW-months/year |
- - $ |
- - $ |
- - $ |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
08: 2.7142 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS |
Savings: $2,407 Cost: $16,180 |
$1,249 | 14,496 | $1,161 | 60 | $83 | - | $(-86) | - | - | - |
$1,249 14,496 kWh |
$1,161 60 kW-months/year |
$83 - $ |
$(-86) - $ |
- - $ |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
TOTAL RECOMMENDED |
Savings: $66,387 Cost: $71,965 |
$24,881 | 296,920 | $26,885 | 1,394 | $2,146 | - | $(-86) | - | $12,561 | - | $24,881 296,920 kWh |
$26,885 1,394 kW-months/year |
$2,146 - $ |
$(-86) - $ |
$12,561 - $ |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
TOTAL IMPLEMENTED |
Savings: $13,019 Cost: $47,836 |
$7,392 | 93,890 | $5,630 | 292 | $83 | - | $(-86) | - | - | - | $7,392 93,890 kWh |
$5,630 292 kW-months/year |
$83 - $ |
$(-86) - $ |
- - $ |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
Savings Cost |
$ | kWh | $ | kW-months/year | $ | $ | $ | $ | $ | $ | |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
Electricity Usage | Electricity Demand | Administrative Changes | Primary Raw Material | One-time Revenue or Avoided Cost | Electricity Usage | Electricity Demand | Administrative Changes | Primary Raw Material | One-time Revenue or Avoided Cost |