Implementation Grant Funding Opportunity Open
IMPORTANT: The grant program operates on a rolling basis and applications may be submitted at any time, with quarterly reviews.
Learn More
Implementation Grant Funding Opportunity Open
Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
IAC Center | San Francisco State University |
---|---|
Assessment Year | 2012 |
Principal Product | Food Product Machinery |
NAICS | 333241 - Food Product Machinery Manufacturing |
SIC | 3556 - Food Products Machinery |
Sales | $50,000,000-$100,000,000 |
# of Employees | 143 |
Plant Area (Sq.Ft.) | 300,000 |
Annual Production | 150 Pieces |
Production Hrs. Annual | 2,565 |
Location (State) | CA |
Source | Yearly Cost | Usage | Unit | Unit Cost |
---|---|---|---|---|
Electricity Usage | $188,422 | 1,921,117 | kWh | $0.10 |
Electricity Demand | $86,173 | 5,700 | kW-months/year | $15.12 |
Natural Gas | $67,789 | 9,135 | MMBtu | $7.42 |
TOTAL ENERGY COSTS | $342,384 | |||
RECOMMENDED SAVINGS* | $77,676 | *Non-energy impacts included in savings. See recommendations below |
||
IMPLEMENTED SAVINGS* | $54,472 |
#|Description |
Savings Cost |
Status | Electricity Usage | Electricity Demand | Electricity Fees | Natural Gas | Electricity Usage | Electricity Demand | Electricity Fees | Natural Gas | |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
$ | kWh | $ | kW-months/year | $ | $ | $ | MMBtu | ||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
01: 2.7221 LOWER TEMPERATURE DURING THE WINTER SEASON AND VICE-VERSA |
Savings: $40,533 Cost: - |
$22,272 | 227,029 | - | - | - | - | $18,261 | 2,461 |
$22,272 227,029 kWh |
- - kW-months/year |
- - $ |
$18,261 2,461 MMBtu |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
02: 2.4236 ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES |
Savings: $8,408 Cost: - |
$8,408 | 94,280 | - | - | - | - | - | - |
$8,408 94,280 kWh |
- - kW-months/year |
- - $ |
- - MMBtu |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
03: 2.4323 USE OPTIMUM SIZE AND CAPACITY EQUIPMENT |
Savings: $10,193 Cost: $9,787 |
$10,193 | 103,905 | - | - | - | - | - | - |
$10,193 103,905 kWh |
- - kW-months/year |
- - $ |
- - MMBtu |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
04: 2.7142 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS |
Savings: $4,230 Cost: $15,467 |
$3,830 | 39,037 | $400 | 26 | - | - | - | - |
$3,830 39,037 kWh |
$400 26 kW-months/year |
- - $ |
- - MMBtu |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
05: 2.7135 INSTALL OCCUPANCY SENSORS |
Savings: $1,301 Cost: $8,388 |
$730 | 7,436 | $571 | 37 | - | - | - | - |
$730 7,436 kWh |
$571 37 kW-months/year |
- - $ |
- - MMBtu |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
06: 2.8114 CHANGE RATE SCHEDULES OR OTHER CHANGES IN UTILITY SERVICE |
Savings: $11,222 Cost: - |
- | - | - | - | $11,222 | - | - | - |
- - kWh |
- - kW-months/year |
$11,222 - $ |
- - MMBtu |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
07: 2.3131 RESCHEDULE PLANT OPERATIONS OR REDUCE LOAD TO AVOID PEAKS |
Savings: $1,705 Cost: - |
- | - | - | - | $1,705 | - | - | - |
- - kWh |
- - kW-months/year |
$1,705 - $ |
- - MMBtu |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
08: 2.4111 UTILIZE ENERGY-EFFICIENT BELTS AND OTHER IMPROVED MECHANISMS |
Savings: $84 Cost: $107 |
$17 | 174 | $67 | 5 | - | - | - | - |
$17 174 kWh |
$67 5 kW-months/year |
- - $ |
- - MMBtu |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
09: 2.8114 CHANGE RATE SCHEDULES OR OTHER CHANGES IN UTILITY SERVICE |
Savings: $0 Cost: - |
- | - | - | - | $0 | - | - | - |
- - kWh |
- - kW-months/year |
$0 - $ |
- - MMBtu |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
TOTAL RECOMMENDED |
Savings: $77,676 Cost: $33,749 |
$45,450 | 471,861 | $1,038 | 68 | $12,927 | - | $18,261 | 2,461 | $45,450 471,861 kWh |
$1,038 68 kW-months/year |
$12,927 - $ |
$18,261 2,461 MMBtu |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
TOTAL IMPLEMENTED |
Savings: $54,472 Cost: $23,855 |
$35,240 | 367,782 | $971 | 64 | - | - | $18,261 | 2,461 | $35,240 367,782 kWh |
$971 64 kW-months/year |
- - $ |
$18,261 2,461 MMBtu |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
Savings Cost |
$ | kWh | $ | kW-months/year | $ | $ | $ | MMBtu | |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
Electricity Usage | Electricity Demand | Electricity Fees | Natural Gas | Electricity Usage | Electricity Demand | Electricity Fees | Natural Gas |