IAC logo
IAC Assessment: SF0458
Sponsored by:
DOE MESC
IAC logo
IAC Assessment: SF0458
Implementation Grant Funding Opportunity Open
IMPORTANT: The grant program operates on a rolling basis and applications may be submitted at any time, with quarterly reviews.
Learn More
Implementation Grant Funding Opportunity Open
Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
IAC Center San Francisco State University
Assessment Year 2014
Principal Product Cooling Towers
NAICS 333415 - Air-Conditioning and Warm Air Heating Equipment and Commercial and Industrial Refrigeration Equipmen
SIC 3585 - Refrigeration And Heating Equipment
Sales $50,000,000-$100,000,000
# of Employees 150
Plant Area (Sq.Ft.) 145,000
Annual Production 850 Pieces
Production Hrs. Annual 4,550
Location (State) CA
Source Yearly Cost Usage Unit Unit Cost
Electricity Usage $241,101 1,637,615 kWh $0.15
Electricity Demand $56,504 5,563 kW-months/year $10.16
Natural Gas $4,728 458 MMBtu $10.32
TOTAL ENERGY COSTS $302,333
RECOMMENDED SAVINGS* $38,190 *Non-energy impacts
included in savings.
See recommendations below
IMPLEMENTED SAVINGS* $15,139
#|Description Savings
Cost
Status Electricity Usage Electricity Demand Administrative Changes Primary Raw Material Electricity Usage Electricity Demand Administrative Changes Primary Raw Material
$ kWh $ kW-months/year $ $ $ $
01: 2.2135 REPAIR AND ELIMINATE STEAM LEAKS Savings:
$6,859
Cost:
$840
$6,859 49,894 - - - - - - $6,859
49,894
kWh
-
-
kW-months/year
-
-
$
-
-
$
02: 2.3131 RESCHEDULE PLANT OPERATIONS OR REDUCE LOAD TO AVOID PEAKS Savings:
$1,195
Cost:
-
- - $1,195 118 - - - - -
-
kWh
$1,195
118
kW-months/year
-
-
$
-
-
$
03: 2.6218 TURN OFF EQUIPMENT WHEN NOT IN USE Savings:
$2,339
Cost:
-
$2,339 17,011 - - - - - - $2,339
17,011
kWh
-
-
kW-months/year
-
-
$
-
-
$
04: 2.7264 INTERLOCK HEATING AND AIR CONDITIONING SYSTEMS TO PREVENT SIMULTANEOUS OPERATION Savings:
$1,582
Cost:
$522
$1,582 11,508 - - - - - - $1,582
11,508
kWh
-
-
kW-months/year
-
-
$
-
-
$
05: 2.7142 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS Savings:
$15,813
Cost:
$30,411
$15,404 112,056 $37 4 $372 - - - $15,404
112,056
kWh
$37
4
kW-months/year
$372
-
$
-
-
$
06: 2.4111 UTILIZE ENERGY-EFFICIENT BELTS AND OTHER IMPROVED MECHANISMS Savings:
$459
Cost:
$1,384
$352 2,558 $107 11 - - - - $352
2,558
kWh
$107
11
kW-months/year
-
-
$
-
-
$
07: 2.7135 INSTALL OCCUPANCY SENSORS Savings:
$1,683
Cost:
$6,142
$1,307 9,504 $376 37 - - - - $1,307
9,504
kWh
$376
37
kW-months/year
-
-
$
-
-
$
08: 3.5217 REUSE / RECYCLE/ SELL PAPER PRODUCTS Savings:
$3,900
Cost:
-
- - - - - - $3,900 - -
-
kWh
-
-
kW-months/year
-
-
$
$3,900
-
$
09: 3.6193 INSTALL EQUIPMENT (eg COMPACTOR) TO REDUCE DISPOSAL COSTS Savings:
$4,360
Cost:
$37,774
- - - - - - $4,360 - -
-
kWh
-
-
kW-months/year
-
-
$
$4,360
-
$
TOTAL RECOMMENDED Savings:
$38,190
Cost:
$77,073
$27,843 202,531 $1,715 169 $372 - $8,260 - $27,843
202,531
kWh
$1,715
169
kW-months/year
$372
-
$
$8,260
-
$
TOTAL IMPLEMENTED Savings:
$15,139
Cost:
$2,746
$11,132 80,971 $107 11 - - $3,900 - $11,132
80,971
kWh
$107
11
kW-months/year
-
-
$
$3,900
-
$
Savings
Cost
$ kWh $ kW-months/year $ $ $ $
Electricity Usage Electricity Demand Administrative Changes Primary Raw Material Electricity Usage Electricity Demand Administrative Changes Primary Raw Material