Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
IAC Center | San Francisco State University |
---|---|
Assessment Year | 2015 |
Principal Product | bread and muffins |
NAICS | 311812 - Commercial Bakeries |
SIC | 2051 - Bread, Cake, And Related Products |
Sales | $10,000,000-$50,000,000 |
# of Employees | 130 |
Plant Area (Sq.Ft.) | 86,679 |
Annual Production | 70,000,000 Pounds |
Production Hrs. Annual | 7,488 |
Location (State) | CA |
Source | Yearly Cost | Usage | Unit | Unit Cost |
---|---|---|---|---|
Electricity Usage | $552,779 | 5,947,277 | kWh | $0.09 |
Electricity Demand | $310,391 | 11,480 | kW-months/year | $27.04 |
Natural Gas | $362,933 | 53,424 | MMBtu | $6.79 |
TOTAL ENERGY COSTS | $1,226,103 | |||
RECOMMENDED SAVINGS* | $143,132 | *Non-energy impacts included in savings. See recommendations below |
||
IMPLEMENTED SAVINGS* | $143,132 |
#|Description |
Savings Cost |
Status | Electricity Usage | Electricity Demand | Natural Gas | Personnel Changes | Ancillary Material Cost | Water Consumption | Electricity Usage | Electricity Demand | Natural Gas | Personnel Changes | Ancillary Material Cost | Water Consumption | |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
$ | kWh | $ | kW-months/year | $ | MMBtu | $ | $ | $ | $ | $ | Tgal | ||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
01: 2.4231 REDUCE THE PRESSURE OF COMPRESSED AIR TO THE MINIMUM REQUIRED |
Savings: $10,220 Cost: $4,488 |
$7,083 | 76,198 | $3,137 | 116 | - | - | - | - | - | - | - | - |
$7,083 76,198 kWh |
$3,137 116 kW-months/year |
- - MMBtu |
- - $ |
- - $ |
- - Tgal |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
02: 2.6231 UTILIZE CONTROLS TO OPERATE EQUIPMENT ONLY WHEN NEEDED |
Savings: $5,421 Cost: $3,541 |
$5,421 | 58,318 | - | - | - | - | - | - | - | - | - | - |
$5,421 58,318 kWh |
- - kW-months/year |
- - MMBtu |
- - $ |
- - $ |
- - Tgal |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
03: 2.2121 INCREASE AMOUNT OF CONDENSATE RETURNED |
Savings: $26,563 Cost: $30,811 |
- | - | - | - | $14,293 | 2,099 | - | - | - | - | $12,270 | - |
- - kWh |
- - kW-months/year |
$14,293 2,099 MMBtu |
- - $ |
- - $ |
$12,270 - Tgal |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
04: 2.2414 USE WASTE HEAT FROM HOT FLUE GASES TO PREHEAT |
Savings: $5,546 Cost: $11,844 |
- | - | - | - | $5,546 | 816 | - | - | - | - | - | - |
- - kWh |
- - kW-months/year |
$5,546 816 MMBtu |
- - $ |
- - $ |
- - Tgal |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
05: 2.7142 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS |
Savings: $4,206 Cost: $17,797 |
$3,834 | 41,246 | - | - | - | - | $598 | - | $(-226) | - | - | - |
$3,834 41,246 kWh |
- - kW-months/year |
- - MMBtu |
$598 - $ |
$(-226) - $ |
- - Tgal |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
06: 2.9114 USE SOLAR HEAT TO MAKE ELECTRICTY |
Savings: $91,176 Cost: $450,224 |
$52,052 | 559,997 | $39,124 | 1,447 | - | - | - | - | - | - | - | - |
$52,052 559,997 kWh |
$39,124 1,447 kW-months/year |
- - MMBtu |
- - $ |
- - $ |
- - Tgal |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
TOTAL RECOMMENDED |
Savings: $143,132 Cost: $518,705 |
$68,390 | 735,759 | $42,261 | 1,563 | $19,839 | 2,915 | $598 | - | $(-226) | - | $12,270 | - | $68,390 735,759 kWh |
$42,261 1,563 kW-months/year |
$19,839 2,915 MMBtu |
$598 - $ |
$(-226) - $ |
$12,270 - Tgal |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
TOTAL IMPLEMENTED |
Savings: $143,132 Cost: $518,705 |
$68,390 | 735,759 | $42,261 | 1,563 | $19,839 | 2,915 | $598 | - | $(-226) | - | $12,270 | - | $68,390 735,759 kWh |
$42,261 1,563 kW-months/year |
$19,839 2,915 MMBtu |
$598 - $ |
$(-226) - $ |
$12,270 - Tgal |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
Savings Cost |
$ | kWh | $ | kW-months/year | $ | MMBtu | $ | $ | $ | $ | $ | Tgal | |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
Electricity Usage | Electricity Demand | Natural Gas | Personnel Changes | Ancillary Material Cost | Water Consumption | Electricity Usage | Electricity Demand | Natural Gas | Personnel Changes | Ancillary Material Cost | Water Consumption |