IAC logo
IAC Assessment: SF0474
Sponsored by:
DOE MESC
IAC logo
IAC Assessment: SF0474
Implementation Grant Funding Opportunity Open
IMPORTANT: The grant program operates on a rolling basis and applications may be submitted at any time, with quarterly reviews.
Learn More
Implementation Grant Funding Opportunity Open
Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
IAC Center San Francisco State University
Assessment Year 2015
Principal Product Wines
NAICS 312130 - Wineries
SIC 2084 - Wines, Brandy, And Brandy Spirits
Sales $100,000,000-$500,000,000
# of Employees 100
Plant Area (Sq.Ft.) 95,000
Annual Production 2,000,000 Units
Production Hrs. Annual 2,895
Location (State) CA
Source Yearly Cost Usage Unit Unit Cost
Electricity Usage $442,602 2,927,638 kWh $0.15
Natural Gas $102,666 10,484 MMBtu $9.79
TOTAL ENERGY COSTS $545,268
RECOMMENDED SAVINGS* $160,170 *Non-energy impacts
included in savings.
See recommendations below
IMPLEMENTED SAVINGS* $91,025
#|Description Savings
Cost
Status Electricity Usage Natural Gas Personnel Changes Primary Raw Material Electricity Usage Natural Gas Personnel Changes Primary Raw Material
$ kWh $ MMBtu $ $ $ $
01: 2.6218 TURN OFF EQUIPMENT WHEN NOT IN USE Savings:
$1,699
Cost:
-
$1,699 11,239 - - - - - - $1,699
11,239
kWh
-
-
MMBtu
-
-
$
-
-
$
02: 2.4236 ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES Savings:
$2,169
Cost:
-
$2,589 17,122 - - $(-420) - - - $2,589
17,122
kWh
-
-
MMBtu
$(-420)
-
$
-
-
$
03: 2.7224 REDUCE SPACE CONDITIONING DURING NON-WORKING HOURS Savings:
$37,843
Cost:
-
$32,743 216,585 $5,100 521 - - - - $32,743
216,585
kWh
$5,100
521
MMBtu
-
-
$
-
-
$
04: 2.6231 UTILIZE CONTROLS TO OPERATE EQUIPMENT ONLY WHEN NEEDED Savings:
$26,501
Cost:
$5,010
$26,501 175,296 - - - - - - $26,501
175,296
kWh
-
-
MMBtu
-
-
$
-
-
$
05: 2.2621 MODIFY REFRIGERATION SYSTEM TO OPERATE AT A LOWER PRESSURE Savings:
$60,323
Cost:
$13,006
$60,323 399,016 - - - - - - $60,323
399,016
kWh
-
-
MMBtu
-
-
$
-
-
$
06: 2.4146 USE ADJUSTABLE FREQUENCY DRIVE OR MULTIPLE SPEED MOTORS ON EXISTING SYSTEM Savings:
$4,400
Cost:
$6,155
$4,400 29,103 - - - - - - $4,400
29,103
kWh
-
-
MMBtu
-
-
$
-
-
$
07: 2.7142 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS Savings:
$11,353
Cost:
$39,333
$6,698 44,304 - - $1,507 - $3,148 - $6,698
44,304
kWh
-
-
MMBtu
$1,507
-
$
$3,148
-
$
08: 2.7135 INSTALL OCCUPANCY SENSORS Savings:
$1,240
Cost:
$4,506
$1,240 8,200 - - - - - - $1,240
8,200
kWh
-
-
MMBtu
-
-
$
-
-
$
09: 2.2511 INSULATE BARE EQUIPMENT Savings:
$7,582
Cost:
$31,836
$7,582 50,153 - - - - - - $7,582
50,153
kWh
-
-
MMBtu
-
-
$
-
-
$
10: 2.6221 USE MOST EFFICIENT EQUIPMENT AT IT'S MAXIMUM CAPACITY AND LESS EFFICIENT EQUIPMENT ONLY WHEN NECESSARY Savings:
$7,060
Cost:
$29,463
$7,060 46,701 - - - - - - $7,060
46,701
kWh
-
-
MMBtu
-
-
$
-
-
$
TOTAL RECOMMENDED Savings:
$160,170
Cost:
$129,309
$150,835 997,719 $5,100 521 $1,087 - $3,148 - $150,835
997,719
kWh
$5,100
521
MMBtu
$1,087
-
$
$3,148
-
$
TOTAL IMPLEMENTED Savings:
$91,025
Cost:
$79,961
$81,690 540,350 $5,100 521 $1,087 - $3,148 - $81,690
540,350
kWh
$5,100
521
MMBtu
$1,087
-
$
$3,148
-
$
Savings
Cost
$ kWh $ MMBtu $ $ $ $
Electricity Usage Natural Gas Personnel Changes Primary Raw Material Electricity Usage Natural Gas Personnel Changes Primary Raw Material