Implementation Grant Funding Opportunity Open
IMPORTANT: The grant program operates on a rolling basis and applications may be submitted at any time, with quarterly reviews.
Learn More
Implementation Grant Funding Opportunity Open
Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
IAC Center | San Francisco State University |
---|---|
Assessment Year | 2016 |
Principal Product | Wine |
NAICS | 312130 - Wineries |
SIC | 2084 - Wines, Brandy, And Brandy Spirits |
Sales | $10,000,000-$50,000,000 |
# of Employees | 113 |
Plant Area (Sq.Ft.) | 180,000 |
Annual Production | 659,000 Units |
Production Hrs. Annual | 4,389 |
Location (State) | CA |
Source | Yearly Cost | Usage | Unit | Unit Cost |
---|---|---|---|---|
Electricity Usage | $342,846 | 2,065,237 | kWh | $0.17 |
Natural Gas | $37,918 | 3,811 | MMBtu | $9.95 |
TOTAL ENERGY COSTS | $380,764 | |||
RECOMMENDED SAVINGS* | $287,291 | *Non-energy impacts included in savings. See recommendations below |
||
IMPLEMENTED SAVINGS* | $285,763 |
#|Description |
Savings Cost |
Status | Electricity Usage | Electricity Demand | Natural Gas | Personnel Changes | Primary Raw Material | Electricity Usage | Electricity Demand | Natural Gas | Personnel Changes | Primary Raw Material | |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
$ | kWh | $ | kW-months/year | $ | MMBtu | $ | $ | $ | $ | ||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
01: 2.4236 ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES |
Savings: $1,727 Cost: - |
$3,407 | 20,521 | - | - | - | - | $(-1,680) | - | - | - |
$3,407 20,521 kWh |
- - kW-months/year |
- - MMBtu |
$(-1,680) - $ |
- - $ |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
02: 2.3137 USE POWER DURING OFF-PEAK PERIODS |
Savings: $1,528 Cost: - |
$11 | 261 | $1,517 | 672 | - | - | - | - | - | - |
$11 261 kWh |
$1,517 672 kW-months/year |
- - MMBtu |
- - $ |
- - $ |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
03: 2.7224 REDUCE SPACE CONDITIONING DURING NON-WORKING HOURS |
Savings: $22,945 Cost: - |
$7,244 | 43,635 | - | - | $15,701 | 1,578 | - | - | - | - |
$7,244 43,635 kWh |
- - kW-months/year |
$15,701 1,578 MMBtu |
- - $ |
- - $ |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
04: 2.2694 USE HIGHEST TEMPERATURE FOR CHILLING OR COLD STORAGE |
Savings: $15,446 Cost: $7,297 |
$15,446 | 93,040 | - | - | - | - | - | - | - | - |
$15,446 93,040 kWh |
- - kW-months/year |
- - MMBtu |
- - $ |
- - $ |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
05: 2.4146 USE ADJUSTABLE FREQUENCY DRIVE OR MULTIPLE SPEED MOTORS ON EXISTING SYSTEM |
Savings: $6,250 Cost: $2,903 |
$6,250 | 35,650 | - | - | - | - | - | - | - | - |
$6,250 35,650 kWh |
- - kW-months/year |
- - MMBtu |
- - $ |
- - $ |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
06: 2.2621 MODIFY REFRIGERATION SYSTEM TO OPERATE AT A LOWER PRESSURE |
Savings: $57,609 Cost: $52,742 |
$57,609 | 347,016 | - | - | - | - | - | - | - | - |
$57,609 347,016 kWh |
- - kW-months/year |
- - MMBtu |
- - $ |
- - $ |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
07: 2.4322 USE OR REPLACE WITH ENERGY EFFICIENT SUBSTITUTES |
Savings: $47,178 Cost: $102,267 |
$47,178 | 284,188 | - | - | - | - | - | - | - | - |
$47,178 284,188 kWh |
- - kW-months/year |
- - MMBtu |
- - $ |
- - $ |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
08: 2.7142 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS |
Savings: $4,956 Cost: $17,949 |
$4,134 | 24,902 | - | - | - | - | $578 | - | $244 | - |
$4,134 24,902 kWh |
- - kW-months/year |
- - MMBtu |
$578 - $ |
$244 - $ |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
09: 2.2511 INSULATE BARE EQUIPMENT |
Savings: $6,631 Cost: $26,784 |
$6,631 | 39,945 | - | - | - | - | - | - | - | - |
$6,631 39,945 kWh |
- - kW-months/year |
- - MMBtu |
- - $ |
- - $ |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
10: 2.7135 INSTALL OCCUPANCY SENSORS |
Savings: $3,368 Cost: $13,975 |
$3,368 | 20,288 | - | - | - | - | - | - | - | - |
$3,368 20,288 kWh |
- - kW-months/year |
- - MMBtu |
- - $ |
- - $ |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
11: 2.9114 USE SOLAR HEAT TO MAKE ELECTRICTY |
Savings: $119,653 Cost: $1,013,583 |
$119,653 | 720,756 | - | - | - | - | - | - | - | - |
$119,653 720,756 kWh |
- - kW-months/year |
- - MMBtu |
- - $ |
- - $ |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
TOTAL RECOMMENDED |
Savings: $287,291 Cost: $1,237,500 |
$270,931 | 1,630,202 | $1,517 | 672 | $15,701 | 1,578 | $(-1,102) | - | $244 | - | $270,931 1,630,202 kWh |
$1,517 672 kW-months/year |
$15,701 1,578 MMBtu |
$(-1,102) - $ |
$244 - $ |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
TOTAL IMPLEMENTED |
Savings: $285,763 Cost: $1,237,500 |
$270,920 | 1,629,941 | - | - | $15,701 | 1,578 | $(-1,102) | - | $244 | - | $270,920 1,629,941 kWh |
- - kW-months/year |
$15,701 1,578 MMBtu |
$(-1,102) - $ |
$244 - $ |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
Savings Cost |
$ | kWh | $ | kW-months/year | $ | MMBtu | $ | $ | $ | $ | |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
Electricity Usage | Electricity Demand | Natural Gas | Personnel Changes | Primary Raw Material | Electricity Usage | Electricity Demand | Natural Gas | Personnel Changes | Primary Raw Material |