Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
IAC Center | San Francisco State University |
---|---|
Assessment Year | 2016 |
Principal Product | Treated Wastewater |
NAICS | 221320 - Sewage Treatment Facilities |
SIC | 4952 - Sewerage Systems |
Sales | $10,000,000-$50,000,000 |
# of Employees | 75 |
Plant Area (Sq.Ft.) | 300,000 |
Annual Production | 2,900,000 Thousand Gallons |
Production Hrs. Annual | 8,760 |
Location (State) | CA |
Source | Yearly Cost | Usage | Unit | Unit Cost |
---|---|---|---|---|
Electricity Usage | $570,896 | 6,755,363 | kWh | $0.08 |
Electricity Demand | $303,459 | 12,849 | kW-months/year | $23.62 |
Natural Gas | $4,508 | 463 | MMBtu | $9.74 |
TOTAL ENERGY COSTS | $878,864 | |||
RECOMMENDED SAVINGS* | $396,584 | *Non-energy impacts included in savings. See recommendations below |
||
IMPLEMENTED SAVINGS* | $392,628 |
#|Description |
Savings Cost |
Status | Electricity Usage | Electricity Demand | Electricity Fees | Natural Gas | Administrative Changes | Ancillary Material Cost | Electricity Usage | Electricity Demand | Electricity Fees | Natural Gas | Administrative Changes | Ancillary Material Cost | |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
$ | kWh | $ | kW-months/year | $ | $ | $ | MMBtu | $ | $ | $ | $ | ||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
01: 2.3137 USE POWER DURING OFF-PEAK PERIODS |
Savings: $5,976 Cost: - |
- | - | - | - | $5,976 | - | - | - | - | - | - | - |
- - kWh |
- - kW-months/year |
$5,976 - $ |
- - MMBtu |
- - $ |
- - $ |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
02: 2.7311 VENTILATION SYSTEM TO SHUT OFF WHEN ROOM IS NOT IN USE |
Savings: $6,324 Cost: $2,354 |
$6,324 | 74,837 | - | - | - | - | - | - | - | - | - | - |
$6,324 74,837 kWh |
- - kW-months/year |
- - $ |
- - MMBtu |
- - $ |
- - $ |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
03: 2.4146 USE ADJUSTABLE FREQUENCY DRIVE OR MULTIPLE SPEED MOTORS ON EXISTING SYSTEM |
Savings: $12,559 Cost: $6,856 |
$9,028 | 106,831 | $3,531 | 150 | - | - | - | - | - | - | - | - |
$9,028 106,831 kWh |
$3,531 150 kW-months/year |
- - $ |
- - MMBtu |
- - $ |
- - $ |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
04: 3.4111 USE CLOSED CYCLE PROCESS TO MINIMIZE WASTE WATER PRODUCTION |
Savings: $3,956 Cost: $2,003 |
$3,956 | 46,810 | - | - | - | - | - | - | - | - | - | - |
$3,956 46,810 kWh |
- - kW-months/year |
- - $ |
- - MMBtu |
- - $ |
- - $ |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
05: 2.7135 INSTALL OCCUPANCY SENSORS |
Savings: $18,801 Cost: $20,415 |
$17,201 | 203,537 | $1,600 | 68 | - | - | - | - | - | - | - | - |
$17,201 203,537 kWh |
$1,600 68 kW-months/year |
- - $ |
- - MMBtu |
- - $ |
- - $ |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
06: 2.7142 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS |
Savings: $25,062 Cost: $48,543 |
$19,489 | 230,609 | $5,591 | 237 | - | - | - | - | $2,519 | - | $(-2,537) | - |
$19,489 230,609 kWh |
$5,591 237 kW-months/year |
- - $ |
- - MMBtu |
$2,519 - $ |
$(-2,537) - $ |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
07: 2.3415 USE A FOSSIL FUEL ENGINE TO COGENERATE ELECTRICITY OR MOTIVE POWER; AND UTILIZE HEAT |
Savings: $323,906 Cost: $1,095,380 |
$405,790 | 4,801,680 | $155,892 | 6,600 | - | - | $(-78,224) | (-14,459) | $(-159,552) | - | - | - |
$405,790 4,801,680 kWh |
$155,892 6,600 kW-months/year |
- - $ |
$(-78,224) (-14,459) MMBtu |
$(-159,552) - $ |
- - $ |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
TOTAL RECOMMENDED |
Savings: $396,584 Cost: $1,175,551 |
$461,788 | 5,464,304 | $166,614 | 7,054 | $5,976 | - | $(-78,224) | (-14,459) | $(-157,033) | - | $(-2,537) | - | $461,788 5,464,304 kWh |
$166,614 7,054 kW-months/year |
$5,976 - $ |
$(-78,224) (-14,459) MMBtu |
$(-157,033) - $ |
$(-2,537) - $ |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
TOTAL IMPLEMENTED |
Savings: $392,628 Cost: $1,173,548 |
$457,832 | 5,417,494 | $166,614 | 7,054 | $5,976 | - | $(-78,224) | (-14,459) | $(-157,033) | - | $(-2,537) | - | $457,832 5,417,494 kWh |
$166,614 7,054 kW-months/year |
$5,976 - $ |
$(-78,224) (-14,459) MMBtu |
$(-157,033) - $ |
$(-2,537) - $ |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
Savings Cost |
$ | kWh | $ | kW-months/year | $ | $ | $ | MMBtu | $ | $ | $ | $ | |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
Electricity Usage | Electricity Demand | Electricity Fees | Natural Gas | Administrative Changes | Ancillary Material Cost | Electricity Usage | Electricity Demand | Electricity Fees | Natural Gas | Administrative Changes | Ancillary Material Cost |