IAC logo
IAC Assessment: SF0481
Sponsored by:
DOE MESC
IAC logo
IAC Assessment: SF0481
Implementation Grant Funding Opportunity Open
IMPORTANT: The grant program operates on a rolling basis and applications may be submitted at any time, with quarterly reviews.
Learn More
Implementation Grant Funding Opportunity Open
Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
IAC Center San Francisco State University
Assessment Year 2016
Principal Product Non-Carbonated Beverages
NAICS 311421 - Fruit and Vegetable Canning
SIC 2086 - Bottled And Canned Soft Drinks
Sales $10,000,000-$50,000,000
# of Employees 192
Plant Area (Sq.Ft.) 387,000
Annual Production 47,000 Units
Production Hrs. Annual 7,248
Location (State) CA
Source Yearly Cost Usage Unit Unit Cost
Electricity Usage $647,031 5,997,816 kWh $0.11
Electricity Demand $552,243 18,864 kW-months/year $29.27
Natural Gas $778,045 140,333 MMBtu $5.54
Other Energy $748,172 5,282,671 MMBtu $0.14
TOTAL ENERGY COSTS $2,725,491
RECOMMENDED SAVINGS* $247,116 *Non-energy impacts
included in savings.
See recommendations below
IMPLEMENTED SAVINGS* $81,221
#|Description Savings
Cost
Status Electricity Usage Electricity Demand Electricity Fees Natural Gas Personnel Changes Ancillary Material Cost Electricity Usage Electricity Demand Electricity Fees Natural Gas Personnel Changes Ancillary Material Cost
$ kWh $ kW-months/year $ $ $ MMBtu $ $ $ $
01: 2.4231 REDUCE THE PRESSURE OF COMPRESSED AIR TO THE MINIMUM REQUIRED Savings:
$4,477
Cost:
$140
$3,089 28,637 $1,388 47 - - - - - - - - $3,089
28,637
kWh
$1,388
47
kW-months/year
-
-
$
-
-
MMBtu
-
-
$
-
-
$
02: 2.3131 RESCHEDULE PLANT OPERATIONS OR REDUCE LOAD TO AVOID PEAKS Savings:
$10,662
Cost:
-
- - - - $10,662 - - - - - - - -
-
kWh
-
-
kW-months/year
$10,662
-
$
-
-
MMBtu
-
-
$
-
-
$
03: 2.7224 REDUCE SPACE CONDITIONING DURING NON-WORKING HOURS Savings:
$16,033
Cost:
-
$9,576 88,767 - - - - $6,457 1,166 - - - - $9,576
88,767
kWh
-
-
kW-months/year
-
-
$
$6,457
1,166
MMBtu
-
-
$
-
-
$
04: 2.1233 ANALYZE FLUE GAS FOR PROPER AIR/FUEL RATIO Savings:
$5,008
Cost:
-
- - - - - - $10,008 1,807 $(-5,000) - - - -
-
kWh
-
-
kW-months/year
-
-
$
$10,008
1,807
MMBtu
$(-5,000)
-
$
-
-
$
05: 2.6218 TURN OFF EQUIPMENT WHEN NOT IN USE Savings:
$23,373
Cost:
-
$23,373 216,661 - - - - - - - - - - $23,373
216,661
kWh
-
-
kW-months/year
-
-
$
-
-
MMBtu
-
-
$
-
-
$
06: 2.7142 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS Savings:
$908
Cost:
$105
$328 3,044 $148 5 - - - - $19 - $413 - $328
3,044
kWh
$148
5
kW-months/year
-
-
$
-
-
MMBtu
$19
-
$
$413
-
$
07: 2.4111 UTILIZE ENERGY-EFFICIENT BELTS AND OTHER IMPROVED MECHANISMS Savings:
$1,030
Cost:
$208
$716 6,635 $314 11 - - - - - - - - $716
6,635
kWh
$314
11
kW-months/year
-
-
$
-
-
MMBtu
-
-
$
-
-
$
08: 2.2692 USE OUTSIDE COLD WATER SOURCE AS A SUPPLY OF COOLING WATER Savings:
$119,304
Cost:
$36,151
$82,947 768,886 $36,357 1,242 - - - - - - - - $82,947
768,886
kWh
$36,357
1,242
kW-months/year
-
-
$
-
-
MMBtu
-
-
$
-
-
$
09: 2.4224 UPGRADE CONTROLS ON COMPRESSORS Savings:
$48,481
Cost:
$18,682
$48,481 449,401 - - - - - - - - - - $48,481
449,401
kWh
-
-
kW-months/year
-
-
$
-
-
MMBtu
-
-
$
-
-
$
10: 2.2511 INSULATE BARE EQUIPMENT Savings:
$660
Cost:
$769
- - - - - - $660 119 - - - - -
-
kWh
-
-
kW-months/year
-
-
$
$660
119
MMBtu
-
-
$
-
-
$
11: 2.2414 USE WASTE HEAT FROM HOT FLUE GASES TO PREHEAT Savings:
$7,601
Cost:
$10,000
- - - - - - $7,601 1,372 - - - - -
-
kWh
-
-
kW-months/year
-
-
$
$7,601
1,372
MMBtu
-
-
$
-
-
$
12: 2.4146 USE ADJUSTABLE FREQUENCY DRIVE OR MULTIPLE SPEED MOTORS ON EXISTING SYSTEM Savings:
$6,674
Cost:
$10,567
$4,640 43,012 $2,034 69 - - - - - - - - $4,640
43,012
kWh
$2,034
69
kW-months/year
-
-
$
-
-
MMBtu
-
-
$
-
-
$
13: 2.1243 USE HEAT FROM BOILER BLOWDOWN TO PREHEAT BOILER FEED WATER Savings:
$2,905
Cost:
$11,333
- - - - - - $2,905 524 - - - - -
-
kWh
-
-
kW-months/year
-
-
$
$2,905
524
MMBtu
-
-
$
-
-
$
TOTAL RECOMMENDED Savings:
$247,116
Cost:
$87,955
$173,150 1,605,043 $40,241 1,375 $10,662 - $27,631 4,988 $(-4,981) - $413 - $173,150
1,605,043
kWh
$40,241
1,375
kW-months/year
$10,662
-
$
$27,631
4,988
MMBtu
$(-4,981)
-
$
$413
-
$
TOTAL IMPLEMENTED Savings:
$81,221
Cost:
$19,696
$61,474 569,849 $1,536 52 $10,662 - $7,117 1,285 $19 - $413 - $61,474
569,849
kWh
$1,536
52
kW-months/year
$10,662
-
$
$7,117
1,285
MMBtu
$19
-
$
$413
-
$
Savings
Cost
$ kWh $ kW-months/year $ $ $ MMBtu $ $ $ $
Electricity Usage Electricity Demand Electricity Fees Natural Gas Personnel Changes Ancillary Material Cost Electricity Usage Electricity Demand Electricity Fees Natural Gas Personnel Changes Ancillary Material Cost