Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
IAC Center | San Francisco State University |
---|---|
Assessment Year | 2017 |
Principal Product | Wine |
NAICS | 312130 - Wineries |
SIC | 2084 - Wines, Brandy, And Brandy Spirits |
Sales | $100,000,000-$500,000,000 |
# of Employees | 91 |
Plant Area (Sq.Ft.) | 276,287 |
Annual Production | 6,000 Thousand Gallons |
Production Hrs. Annual | 3,480 |
Location (State) | CA |
Source | Yearly Cost | Usage | Unit | Unit Cost |
---|---|---|---|---|
Electricity Usage | $371,192 | 3,511,307 | kWh | $0.11 |
Electricity Demand | $179,755 | 5,832 | kW-months/year | $30.82 |
Natural Gas | $46,574 | 4,654 | MMBtu | $10.01 |
TOTAL ENERGY COSTS | $597,521 | |||
RECOMMENDED SAVINGS* | $136,581 | *Non-energy impacts included in savings. See recommendations below |
||
IMPLEMENTED SAVINGS* | $80,854 |
#|Description |
Savings Cost |
Status | Electricity Usage | Electricity Demand | Natural Gas | Personnel Changes | Ancillary Material Cost | Electricity Usage | Electricity Demand | Natural Gas | Personnel Changes | Ancillary Material Cost | |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
$ | kWh | $ | kW-months/year | $ | MMBtu | $ | $ | $ | $ | ||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
01: 2.7496 INSTALL PARTITIONS TO REDUCE SIZE OF CONDITIONED SPACE |
Savings: $2,452 Cost: - |
$1,492 | 14,115 | - | - | $960 | 96 | - | - | - | - |
$1,492 14,115 kWh |
- - kW-months/year |
$960 96 MMBtu |
- - $ |
- - $ |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
02: 2.5195 CHANGE PRODUCT DESIGN TO REDUCE ENERGY REQUIREMENTS |
Savings: $6,821 Cost: - |
$6,821 | 64,522 | - | - | - | - | - | - | - | - |
$6,821 64,522 kWh |
- - kW-months/year |
- - MMBtu |
- - $ |
- - $ |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
03: 2.7261 INSTALL TIMERS AND/OR THERMOSTATS |
Savings: $17,732 Cost: $2,539 |
$3,514 | 33,246 | - | - | $14,218 | 1,420 | - | - | - | - |
$3,514 33,246 kWh |
- - kW-months/year |
$14,218 1,420 MMBtu |
- - $ |
- - $ |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
04: 2.4231 REDUCE THE PRESSURE OF COMPRESSED AIR TO THE MINIMUM REQUIRED |
Savings: $596 Cost: $140 |
$249 | 2,354 | $347 | 11 | - | - | - | - | - | - |
$249 2,354 kWh |
$347 11 kW-months/year |
- - MMBtu |
- - $ |
- - $ |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
05: 2.6231 UTILIZE CONTROLS TO OPERATE EQUIPMENT ONLY WHEN NEEDED |
Savings: $11,813 Cost: $10,550 |
$11,813 | 99,374 | - | - | - | - | - | - | - | - |
$11,813 99,374 kWh |
- - kW-months/year |
- - MMBtu |
- - $ |
- - $ |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
06: 2.7142 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS |
Savings: $38,416 Cost: $53,848 |
$18,520 | 175,200 | $15,019 | 492 | - | - | $5,259 | - | $(-382) | - |
$18,520 175,200 kWh |
$15,019 492 kW-months/year |
- - MMBtu |
$5,259 - $ |
$(-382) - $ |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
07: 2.4146 USE ADJUSTABLE FREQUENCY DRIVE OR MULTIPLE SPEED MOTORS ON EXISTING SYSTEM |
Savings: $12,893 Cost: $42,428 |
$12,893 | 121,962 | - | - | - | - | - | - | - | - |
$12,893 121,962 kWh |
- - kW-months/year |
- - MMBtu |
- - $ |
- - $ |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
08: 2.1311 REPLACE ELECTRICALLY-OPERATED EQUIPMENT WITH FOSSIL FUEL EQUIPMENT |
Savings: $7,625 Cost: $31,216 |
$6,204 | 58,689 | $3,233 | 105 | $(-1,812) | (-181) | - | - | - | - |
$6,204 58,689 kWh |
$3,233 105 kW-months/year |
$(-1,812) (-181) MMBtu |
- - $ |
- - $ |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
09: 4.212 ADOPT IN-HOUSE MATERIAL GENERATION |
Savings: $38,233 Cost: $90,166 |
$(-3,898) | (-36,874) | $(-4,962) | (-161) | - | - | - | - | $47,093 | - |
$(-3,898) (-36,874) kWh |
$(-4,962) (-161) kW-months/year |
- - MMBtu |
- - $ |
$47,093 - $ |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
TOTAL RECOMMENDED |
Savings: $136,581 Cost: $230,887 |
$57,608 | 532,588 | $13,637 | 448 | $13,366 | 1,335 | $5,259 | - | $46,711 | - | $57,608 532,588 kWh |
$13,637 448 kW-months/year |
$13,366 1,335 MMBtu |
$5,259 - $ |
$46,711 - $ |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
TOTAL IMPLEMENTED |
Savings: $80,854 Cost: $109,365 |
$46,740 | 429,782 | $15,019 | 492 | $14,218 | 1,420 | $5,259 | - | $(-382) | - | $46,740 429,782 kWh |
$15,019 492 kW-months/year |
$14,218 1,420 MMBtu |
$5,259 - $ |
$(-382) - $ |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
Savings Cost |
$ | kWh | $ | kW-months/year | $ | MMBtu | $ | $ | $ | $ | |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
Electricity Usage | Electricity Demand | Natural Gas | Personnel Changes | Ancillary Material Cost | Electricity Usage | Electricity Demand | Natural Gas | Personnel Changes | Ancillary Material Cost |